NDAC 33.1-19-01-09
Wastewater treatment facility classifications
Cite as N.D. Admin. Code ยง 33.1-19-01-09
Wastewater treatment facilities must be classified in one of five classes. Classifications must be
based on population served, design population, type of treatment, character and volume of wastes to
be treated, and the use and nature of the water resources receiving the facility effluent. Facilities may
be classified at the discretion of the department if the facility has special design features or complex
features or characteristics unusually difficult to operate, by reason of a waste unusually difficult to treat,
conditions of flow, or the receiving water quality classification requiring an unusually high degree of
facility operational control, or a combination of such conditions or circumstances.
1.
Class IA. All wastewater stabilization ponds, land treatment facilities, wetlands treatment
facilities, or other nonmechanical facilities requiring a minor degree of operational control
serving a population equivalent of less than five hundred persons.
2.
Class I. All wastewater stabilization ponds, land treatment facilities, wetlands treatment
facilities, or other nonmechanical facilities requiring a minor degree of operational control
serving a population equivalent of five hundred to less than ten thousand persons.
3.
Class II.
a.
All mechanical facilities, mechanically aerated stabilization ponds, oxidation ditches, or
other facilities requiring a moderate degree of operational control serving a population
equivalent of less than ten thousand persons.
b.
All wastewater stabilization ponds, land treatment facilities, wetlands treatment facilities,
or other nonmechanical facilities requiring a minor degree of operational control serving a
population equivalent of ten thousand persons or more.
4.
Class III.
a.
All mechanical facilities, mechanically aerated stabilization ponds, oxidation ditches, or
other facilities requiring a moderate degree of operational and laboratory control serving
a population equivalent of ten thousand persons or more.
b.
All activated sludge facilities, trickling filter facilities, rotating biological contactor facilities,
separate sludge stabilization facilities, or other mechanical facilities requiring a high
degree of operational and laboratory control serving a population equivalent of less than
ten thousand persons.
5.
Class IV. All activated sludge facilities, trickling filter facilities, rotating biological contactor
facilities, separate sludge stabilization facilities, or other mechanical facilities requiring a high
degree of operational and laboratory control serving a population equivalent of ten thousand
persons or more.