NDAC 33.1-24-02-172
Standards - Process vents
Cite as N.D. Admin. Code § 33.1-24-02-172
1.
The remanufacturer or other person that stores or treats hazardous secondary materials in
hazardous secondary material management units with process vents associated with
distillation, fractionation, thin-film evaporation, solvent extraction, or air or steam stripping
operations managing hazardous secondary material with organic concentrations of at least
ten parts per million weight either shall:
a.
Reduce total organic emissions from all affected process vents at the facility below
one and four-tenths kilograms per hour (three pounds per hour) and two and eight-tenths
megagrams per year (three and one-tenth tons per year); or
b.
Reduce, by use of a control device, total organic emissions from all affected process
vents at the facility by ninety-five weight percent.
2.
If the remanufacturer or other person that stores or treats the hazardous secondary material
installs a closed-vent system and control device to comply with the provisions of subsection 1
the closed-vent system and control device must meet the requirements of section
33.1-24-02-173.
3.
Determinations of vent emissions and emission reductions or total organic compound
concentrations achieved by add-on control devices may be based on engineering calculations
or performance tests. If performance tests are used to determine vent emissions, emission
reductions, or total organic compound concentrations achieved by add-on control devices, the
performance tests must conform with the requirements of subsection 3 of section
33.1-24-02-174.
4.
When a remanufacturer or other person that stores or treats the hazardous secondary
material and the department do not agree on determinations of vent emissions or emission
reductions, or both, or total organic compound concentrations achieved by add-on control
devices based on engineering calculations, the procedures in subsection 3 of section
33.1-24-02-174 must be used to resolve the disagreement.