NDAC 33.1-24-02-184
Standards - Pressure relief devices in gas or vapor service
Cite as N.D. Admin. Code § 33.1-24-02-184
1.
Except during pressure releases, each pressure relief device in gas or vapor service must be
operated with no detectable emissions, as indicated by an instrument reading of less than five
hundred parts per million above background, as measured by the method specified in
subsection 3 of section 33.1-24-02-193.
2.
Pressure release.
a.
After each pressure release, the pressure relief device must be returned to a condition of
no detectable emissions, as indicated by an instrument reading of less than five hundred
parts per million above background, as soon as practicable, but no later than five
calendar days after each pressure release, except as provided in section
33.1-24-02-189.
b.
No later than five calendar days after the pressure release, the pressure relief device
must be monitored to confirm the condition of no detectable emissions, as indicated by
an instrument reading of less than five hundred parts per million above background, as
measured by the method specified in subsection 3 of section 33.1-24-02-193.
3.
Any pressure relief device that is equipped with a closed-vent system capable of capturing
and transporting leakage from the pressure relief device to a control device as described in
section 33.1-24-02-190 is exempt from the requirements of subsections 1 and 2.