NDAC 33.1-24-02-55
Containment
Cite as N.D. Admin. Code ยง 33.1-24-02-55
1.
Container storage areas must have a containment system that is designed and operated in
accordance with subsection 2.
2.
A containment system must be designed and operated as follows:
a.
A base must underlie the containers which is free of cracks or gaps and is sufficiently
impervious to contain leaks, spills, and accumulated precipitation until the collected
material is detected and removed;
b.
The base must be sloped or the containment system must be otherwise designed and
operated to drain and remove liquids resulting from leaks, spills, or precipitation, unless
the containers are elevated or are otherwise protected from contact with accumulated
liquids;
c.
The containment system must have sufficient capacity to contain ten percent of the
volume of containers or the volume of the largest container, whichever is greater.
d.
Run-on into the containment system must be prevented unless the collection system has
sufficient excess capacity in addition to that required in subdivision c to contain any
run-on which might enter the system; and
e.
Spilled or leaked material and accumulated precipitation must be removed from the sump
or collection area in as timely a manner as is necessary to prevent overflow of the
collection system.