NDAC 33.1-24-03-74
Laboratory clean-outs
Cite as N.D. Admin. Code ยง 33.1-24-03-74
1.
One time per twelve-month period for each laboratory, an eligible academic entity may choose
to conduct a laboratory clean-out that is subject to all the applicable requirements of sections
33.1-24-03-60 through 33.1-24-03-77, except that:
a.
If the volume of unwanted material in the laboratory exceeds fifty-five gallons (or
one quart of liquid reactive acutely hazardous unwanted material or one kilogram of solid
reactive acutely hazardous unwanted material), the eligible academic entity is not
required to remove all unwanted materials from the laboratory within ten calendar days of
exceeding fifty-five gallons (or one quart of liquid reactive acutely hazardous unwanted
material or one kilogram of solid reactive acutely hazardous unwanted material), as
required by section 33.1-24-03-69. Instead, the eligible academic entity must remove all
unwanted materials from the laboratory within thirty calendar days from the start of the
laboratory clean-out;
b.
For the purposes of onsite accumulation, an eligible academic entity is not required to
count a hazardous waste that is an unused commercial chemical product (listed in
sections 33.1-24-02-15 through 33.1-24-02-19, or exhibiting one or more characteristics
in sections 33.1-24-02-10 through 33.1-24-02-14) generated solely during the laboratory
clean-out toward its hazardous waste generator status, pursuant to subsection 2 of
section 33.1-24-03-03. An unwanted material that is generated prior to the beginning of
the laboratory clean-out and is still in the laboratory at the time the laboratory clean-out
commences must be counted toward hazardous waste generator status, pursuant to
subsection 2 of section 33.1-24-03-03, if it is determined to be hazardous waste;
c.
For the purposes of offsite management, an eligible academic entity must count all its
hazardous waste, regardless of whether the hazardous waste was counted toward
generator status under subdivision b, and if the eligible academic entity generates more
than one kilogram per month of acute hazardous waste, or one hundred kilograms per
month of hazardous waste (for example, the very small quantity generator limits of
section 33.1-24-03-26), the hazardous waste is subject to all applicable hazardous waste
regulations when the hazardous waste is transported offsite; and
d.
An eligible academic entity must document the activities of the laboratory clean-out. The
documentation must, at a minimum, identify the laboratory being cleaned out, the date
the laboratory clean-out begins and ends, and the volume of hazardous waste generated
during the laboratory clean-out. The eligible academic entity must maintain the records
for a period of three years from the date the clean-out ends; and
2.
For all other laboratory clean-outs conducted during the same twelve-month period, an eligible
academic entity is subject to all the applicable requirements of sections 33.1-24-03-60 through
33.1-24-03-77, including:
a.
The requirement to remove all unwanted materials from the laboratory within
ten calendar days of exceeding fifty-five gallons (or one quart of reactive acutely
hazardous unwanted material), as required by section 33.1-24-03-69; and
b.
The requirement to count all hazardous waste, including unused hazardous waste,
generated during the laboratory clean-out toward its hazardous waste generator status,
pursuant to subsection 2 of section 33.1-24-03-03.