NDAC 33.1-24-05-132
Monitoring and inspection
Cite as N.D. Admin. Code § 33.1-24-05-132
1.
During construction or installation, liners (except in the case of existing portions of piles
exempt from subsection 1 of section 33.1-24-05-131) and cover systems (for example,
membranes, sheets, or coatings) must be inspected for uniformity, damage, and
imperfections, for example, holes, cracks, thin spots, or foreign materials. Immediately after
construction or installation:
a.
Synthetic liners and covers must be inspected to ensure tight seams and joints and the
absence of tears, punctures, or blisters; and
b.
Soil-based and admixed liners and covers must be inspected for imperfections, including
lenses, cracks, channels, root holes, or other structural nonuniformities that may cause
an increase in the permeability of the liner or cover.
2.
While a waste pile is in operation, it must be inspected weekly and after storms to detect
evidence of any of the following:
a.
Deterioration, malfunctions, or improper operation of run-on and runoff control systems;
b.
Proper functioning of wind dispersal control systems where present; and
c.
The presence of leachate in and proper functioning of leachate collection and removal
systems, where present.
3.
An owner or operator required to have a leak detection system under subsection 2 of section
33.1-24-05-131 must record the amount of liquids removed from each leak detection system
sump at least once each week during the active life and closure period.