NDAC 33.1-24-05-138
Response actions
Cite as N.D. Admin. Code § 33.1-24-05-138
1.
The owner or operator of waste pile units subject to subsection 2 or 3 of section
33.1-24-05-131 must have an approved response action plan before receipt of waste. The
response action plan must set forth the actions to be taken if the action leakage rate has been
exceeded. At a minimum, the response action plan must describe the actions specified in
subsection 2.
2.
If the flow rate into the leak detection system exceeds the action leakage rate for any sump,
the owner or operator must:
a.
Notify the department in writing of the exceedance within seven days of the
determination;
b.
Submit a preliminary written assessment to the department within fourteen days of the
determination, as to the amount of liquids, likely sources of liquids, possible location,
size, and cause of any leaks, and short-term actions taken and planned;
c.
Determine to the extent practicable the location, size, and cause of any leak;
d.
Determine whether waste receipt should cease or be curtailed; whether any waste
should be removed from the unit for inspection, repairs, or controls; and whether or not
the unit should be closed;
e.
Determine any other short-term and long-term actions to be taken to mitigate or stop any
leaks; and
f.
Within thirty days after the notification that the action leakage rate has been exceeded,
submit to the department the results of the analyses specified in subdivisions c, d, and e;
the results of actions taken; and actions planned. Monthly thereafter, as long as the flow
rate in the leak detection system exceeds the action leakage rate, the owner or operator
must submit to the department a report summarizing the results of any remedial actions
taken and actions planned.
3.
To make the leak or remediation determinations, or both, in subdivisions c, d, and e of
subsection 2, the owner or operator must:
a.
Assess and conduct the following:
(1)
Assess the source of liquids and amounts of liquids by source;
(2)
Conduct a fingerprint, hazardous constituent, or other analyses of the liquids in the
leak detection system to identify the source of liquids and possible location of any
leaks, and the hazard and mobility of the liquid; and
(3)
Assess the seriousness of any leaks in terms of potential for escaping into the
environment; or
b.
Document why such assessments are not needed.