NDAC 33.1-24-06-80
Information required for air emissions control
Cite as N.D. Admin. Code ยง 33.1-24-06-80
If the facility has air emission control equipment subject to sections 33.1-24-05-450 through
33.1-24-05-474, the following information must be kept at the facility:
1.
Documentation for each floating roof cover installed on a tank subject to subdivisions a and b
of subsection 4 of section 33.1-24-05-454 that includes information the owner or operator
prepared or the cover manufacturer or vendor, or both, provided describing the cover design,
and the owner's or operator's certification that the cover meets applicable design
specifications listed in subdivision a of subsection 5 or subdivision a of subsection 6 of section
33.1-24-05-454.
2.
Identification of each container area subject to the requirements of sections 33.1-24-05-450
through 33.1-24-05-474 and the owner's or operator's certification that the requirements of
sections 33.1-24-05-450 through 33.1-24-05-474 are met.
3.
Documentation for each enclosure used to control air pollutant emissions from tanks or
containers under the requirements of subdivision e of subsection 4 of section 33.1-24-05-454
or paragraph 2 of subdivision a of subsection 5 of section 33.1-24-05-456. The owner or
operator must include records for the most recent set of calculations and measurements
performed to verify that the enclosure meets the criteria of a permanent total enclosure as
specified in "Procedure T - Criteria for and Verification of a Permanent or Temporary Total
Enclosure" under 40 CFR 52.741, appendix B.
4.
[Reserved].
5.
Documentation for each closed-vent system and control device installed under the
requirements of section 33.1-24-05-457 that includes design and performance information as
specified in paragraphs 3 and 4 of subdivision cc of subsection 2 of section 33.1-24-06-17.
6.
An emission monitoring plan for both Method 21 in 40 CFR part 60, appendix A, and control
device monitoring methods. This plan must include the following information--monitoring
points, monitoring methods for control devices, monitoring frequency, procedures for
documenting exceedances, and procedures for mitigating noncompliances.