NDAC 33.1-24-08-21
Operation and maintenance of corrosion protection
Cite as N.D. Admin. Code ยง 33.1-24-08-21
All owners and operators of metal underground storage tank systems with corrosion protection
must comply with the following requirements to ensure that releases due to corrosion are prevented
until the underground storage tank system is permanently closed or undergoes a change-in-service
pursuant to section 33.1-24-08-61:
1.
All corrosion protection systems must be operated and maintained to continuously provide
corrosion protection to the metal components of that portion of the tank and piping that
routinely contain regulated substances and are in contact with the ground;
2.
All underground storage tank systems equipped with cathodic protection systems must be
inspected for proper operation by a qualified cathodic protection tester in accordance with the
following requirements:
a.
Frequency. All cathodic protection systems must be tested within six months of
installation and at least every three years thereafter or according to another reasonable
timeframe established by the department;
b.
Inspection criteria. The criteria that are used to determine that cathodic protection is
adequate as required by this section must be in accordance with a code of practice
developed by a nationally recognized association;
NOTE: The following codes of practice may be used to comply with subsection 2: NACE
International Test Method TM0101, "Measurement Techniques Related to Criteria for Cathodic
Protection of Underground Storage Tank Systems"; NACE International Test Method TM0497,
"Measurement Techniques Related to Criteria for Cathodic Protection on Underground or
Submerged Metallic Piping Systems"; Steel Tank Institute Recommended Practice R051,
"Cathodic Protection Testing Procedures for STI-P3ยฎ USTs"; NACE International Standard
Practice SP 0285, "External Control of Underground Storage Tank Systems by Cathodic
Protection"; or NACE International Standard Practice SP 0169, "Control of External Corrosion
on Underground or Submerged Metallic Piping Systems".
3.
Underground storage tank systems with impressed current cathodic protection systems must
also be inspected every sixty days to ensure the equipment is running properly; and
4.
For underground storage tank systems using cathodic protection, records of the operation of
the cathodic protection must be maintained (in accordance with section 33.1-24-08-24) to
demonstrate compliance with the performance standards. These records must provide the
following:
a.
The results of the last three inspections required in subsection 3; and
b.
The results of testing from the last two inspections required in subsection 2.