NDAC 33-33-06-14
Fire safety
Cite as N.D. Admin. Code ยง 33-33-06-14
Bed and breakfast facilities shall be in compliance with the requirements of the Uniform Building
Code and Uniform Fire Code as adopted and enforced by the state fire marshal. The department shall
report to the state fire marshal violations of any provision of the code which might constitute a fire
hazard in the premises so inspected.
The requirements for fire/life/safety shall include, but not be limited to, the following:
1.
Smoke detectors.
a.
A smoke detection device in good operating condition shall be mounted on the ceiling or
wall at a point centrally located in the corridor or area giving access to rooms used for
sleeping purposes. All smoke detectors shall be inspected and listed by underwriters'
laboratories or an equivalent. Smoke detectors shall be installed in accordance with the
manufacturer's installation instructions.
b.
A smoke detector shall be installed in the basement of dwelling units having a stairway
which opens from the basement into the dwelling. Such detector shall be connected to a
sounding device or other detector to provide an alarm which will be audible in the
sleeping area.
c.
The owner of the facility shall test the battery-operated smoke detectors at least weekly
and hard-wired detectors at least monthly and shall maintain written records which detail
the date and results of the test.
2.
Every sleeping unit shall provide a minimum of fifty square feet [4.65 square meters] of floor
area per guest.
3.
Every sleeping unit shall have at least one operable window or exterior door approved for
emergency escape or rescue. The units shall be operable from the inside to provide a full
clear opening without the use of separate tools. All escapes or rescue windows from sleeping
rooms must have a minimum net clear opening of 5.7 square feet [.52 square meters]. The
minimum net clear opening height dimension must be twenty-four inches [60.96 centimeters].
The minimum net clear opening width dimensions must be twenty inches [50.8 centimeters].
Where windows are provided as a means of escape or rescue, they must have a finished sill
height not more than forty-four inches [111.76 centimeters] above the floor. No sleeping unit in
bed and breakfast facilities may be in attic lofts or in basement rooms with a single major
means of escape.
4.
A fire extinguisher rated 2A and having a BC rating must be conveniently located and
accessible in the bed and breakfast facility. The maximum travel distance to the extinguisher
must be no more than seventy-five feet [22.86 meters].
5.
Emergency numbers shall be posted on the telephones in the bed and breakfast facility.