NDAC 33-41-01-08
Sanitation and sterilization procedures
Cite as N.D. Admin. Code ยง 33-41-01-08
1.
All nonsingle-use, nondisposable instruments used for body art shall be cleaned thoroughly
after each use by scrubbing with an appropriate soap or disinfectant solution and hot water or
by following the manufacturer's instructions, to remove blood and tissue residue, and shall be
placed in an ultrasonic unit also operated in accordance with the manufacturer's instructions.
2.
After being cleaned, all nondisposable instruments used for body art shall be packed
individually in peel-packs and subsequently sterilized as specified in subsection 3. All
peel-packs shall contain either a sterilizer indicator or internal temperature indicator.
Peel-packs must be dated with an expiration date not to exceed six months.
3.
All cleaned, nondisposable instruments used for body art shall be sterilized in a steam
autoclave or dry-heat sterilizer (if approved by the department). The sterilizer shall be used,
cleaned, and maintained according to manufacturer's instruction. A copy of the manufacturer's
recommended procedures for the operation of the sterilization unit must be available for
inspection by the department. Sterile equipment may not be used if the package has been
breached or after the expiration date without first repackaging and resterilizing. Sterilizers shall
be located away from workstations or areas frequented by the public. If the body art
establishment uses only single-use, disposable instruments and products, and uses sterile
supplies, an autoclave shall not be required.
4.
Each holder of a license to operate a body art establishment shall demonstrate that the
sterilizer used is capable of attaining sterilization by monthly spore destruction tests. These
tests shall be verified through an independent laboratory. The license shall not be issued or
renewed until documentation of the sterilizer's ability to destroy spores is received by the
department. These test records shall be retained by the operator for a period of three years
and made available to the department upon request.
5.
Tattoo needles and piercing needles are not reusable under any circumstances. After use, all
needles, razors, and other sharps shall be immediately disposed of in red sharps containers,
appropriately labeled with the international biohazard symbol. After sterilization, all reusable
instruments used for tattooing or body piercing shall be stored in a dry, clean cabinet or other
tightly covered container reserved for the storage of such instruments.
6.
All instruments used for tattooing or body piercing shall remain stored in sterile packages until
just prior to the performance of a body art procedure. When assembling instruments used for
body art procedures, the operator shall wear disposable medical gloves and use medically
recognized techniques to ensure that the instruments and gloves are not contaminated.
7.
All inks, dyes, pigments, needles, and equipment shall be specifically manufactured for
performing body art procedures and shall be used according to manufacturer's instructions.
The mixing of approved inks, dyes, or pigments or their dilution with potable water is
acceptable. Immediately before a tattoo is applied, the quantity of the dye to be used shall be
transferred from the dye bottle and placed into single-use paper cups or plastic cups. Upon
completion of the tattoo, these single cups or cups and their contents shall be discarded.