NDAC 43-02-02-24
Method of plugging
Cite as N.D. Admin. Code ยง 43-02-02-24
All wells shall be plugged in a manner which will confine permanently all subsurface minerals, oil,
gas, and water in the separate strata originally containing them. This operation shall be accomplished
by the use of mud-laden fluid, cement, and plugs, used singly or in combination as may be approved by
the director. All casing strings shall be cut off at least three feet [91.44 centimeters] below the final
surface contour, and a cap shall be welded. Core or stratigraphic testholes drilled to or below sands
containing freshwater shall be plugged in accordance with the applicable provisions recited above. After
plugging, the site must be reclaimed pursuant to sections 43-02-02-14.1 and 43-02-02-24.2.