NDAC 43-05-01-09
Well permit application requirements
Cite as N.D. Admin. Code ยง 43-05-01-09
1.
Following receipt of a storage facility permit, the storage operator shall obtain a permit to drill,
deepen, convert, operate, or, upon demonstration of mechanical integrity, reenter a previously
plugged and abandoned well for storage purposes.
2.
Application for permits to drill, deepen, convert, operate, or reenter a well must be submitted
on form 25 provided by the commission and must include at a minimum:
a.
An accurate plat certified by a registered surveyor showing the location of the proposed
injection or subsurface observation well. The plat must be drawn to the scale of one inch
[25.4 millimeters] equals one thousand feet [304.8 meters], unless otherwise directed by
the commission, and must show distances from the proposed well to the nearest facility
area boundary. The plat must show the latitude and longitude of the proposed well
location to the nearest tenth of a second. The plat must also show the location and status
of all other wells that have been drilled within one-fourth mile [402.34 meters], or any
other distance deemed necessary by the commission, of the proposed injection or
subsurface observation well;
b.
The drilling, completion, or conversion procedures for the proposed injection or
subsurface observation well;
c.
A well bore schematic showing the name, description, and depth of the storage
reservoirs and the depth of the deepest underground source of drinking water; a
description of the casing in the injection or subsurface observation well, or the proposed
casing program, including a full description of cement already in place or as proposed;
and the proposed method of testing casing before use of the injection well;
d.
A geophysical log, if available, through the storage reservoir to be penetrated by the
proposed injection well or if an injection or subsurface observation well is to be drilled, a
complete log through the reservoir from a nearby well is permissible. Such log must be
annotated to identify the estimated location of the base of the deepest underground
source of drinking water, showing the stratigraphic position and thickness of all confining
strata above the reservoirs and the stratigraphic position and thickness of the reservoir;
and
e.
The proposed pad layout, including cut and fill diagrams.
3.
Within thirty days after the conclusion of well drilling and completion activities, a permit
application shall be submitted to operate an injection well and must include at a minimum:
a.
A schematic diagram of the surface injection system and its appurtenances;
b.
A final well bore diagram showing the name, description, and depths of the storage
reservoir and the base of the deepest underground source of drinking water and a
diagram of the well depicting the casing, cementing, perforation, tubing, and plug and
packer records associated with the construction of the well;
c.
The well's complete dual induction or equivalent log through the storage reservoir. Such
a log shall be run prior to setting casing through the storage reservoir. Logs must be
annotated to identify the estimated location of the base of the deepest underground
source of drinking water, showing the stratigraphic position and thickness of all confining
strata above the storage reservoir and the reservoir's stratigraphic position and thickness
unless that information has been previously submitted. When approved in advance by
the commission, this information can be demonstrated with a dual induction or equivalent
log run in a nearby well or by such other method acceptable to the commission;
d.
An affidavit specifying the chemical constituents, their relative proportions and the
physical properties of the carbon dioxide stream, and the source of the carbon dioxide
stream;
e.
Proof that the long string of casing of the well is cemented adequately so that the carbon
dioxide is confined to the storage reservoirs. Such proof must be provided in the form of
a cement bond log or the results of a fluid movement study or such other method
specified by the commission;
f.
The results of a mechanical-integrity test, if applicable to well type, of the casing in
accordance with the pressure test requirements of this section if a test was run within
one calendar year preceding the request for a conversion permit for a previously drilled
well;
g.
The final area of review based on modeling, using data obtained during logging and
testing of the well and the formation, including any relevant updates on the geologic
structure and hydrogeologic properties of the proposed storage reservoir and overlying
formations;
h.
Information on the compatibility of the carbon dioxide stream with fluids in the injection
zone and minerals in both the injection and the confining zone, based on the results of
the formation testing program, and with the materials used to construct the well;
i.
The results of the formation testing program;
j.
The status of corrective action on wells in the area of review;
k.
All available logging and testing program data on the well;
l.
Any updates to the proposed area of review and corrective action plan, testing and
monitoring plan, injection well plugging plan, postinjection site care and facility closure
plan, and the emergency and remedial response plan, which are necessary to address
new information collected during logging and testing of the well; and
m.
Any other information that the commission requires.