NDAC 62-04-02-07
Protection of pipes
Cite as N.D. Admin. Code ยง 62-04-02-07
1.
Breakage. Pipes passing under or through walls shall be protected from breakage. Any
plumbing pipe passing under a footing or through a foundation wall shall be provided with a
relieving arch; or there shall be built into the masonry wall an iron-pipe sleeve two pipe sizes
greater than the pipe passing through; or equivalent protection shall be provided as may be
approved in writing by the administrative authority.
2.
Corrosion. Pipe subject to corrosion by passing through or under corrosive fill, such as, but
not limited to, cinders, concrete, or other corrosive material, shall be protected against
external corrosion by protective coating, wrapping, or other means which will resist such
corrosion.
3.
Cutting or notching. Any structural member weakened or impaired by cutting, notching, or
otherwise, shall be reinforced, repaired, or replaced, so as to be left in a safe structural
condition in accordance with the requirements of the building code or as required by the
proper administrative authority.