14.7.4.26 NMAC
Lintels
A. General. Lintels of wood or concrete are allowed. The bearing length of any lintel shall not be reduced by an angled or splayed window or door opening. Other lintel designs are accepted providing that engineering is submitted for review by the building official. B. Wood lintels. When an engineerโs drawing and seal is not provided for lintels, all wood lintels shall conform to Table 5 and have a fiber stress rating of at least 850 psi. Table 5 CEB WALL WOOD LINTEL SCHEDULE MINIMUM FIBER STRESS 850 PSI Wall Width Max. Span Size Bearing length on earth wall Load Capacity 10โ 4'-0โ 10โ x 6โ 12โ 860 PLF 6'-0โ 10โ x 8โ 12โ 1020 PLF 8'-0โ 10โ x 10โ 18โ 1150 PLF 10'-0โ 10โ x 12โ 24โ 1000 PLF 12'-0โ 10โ x 14โ 24โ 1000 PLF 12โ 4'-0โ 10โ x 6โ 12โ 860 PLF 6'-0โ 10โ x 8โ 12โ 1020 PLF 8'-0โ 10โ x 10โ 18โ 1150 PLF 10'-0โ 10โ x 12โ 24โ 1000 PLF 12'-0โ 10โ x 14โ 24โ 1000 PLF 14โ 14โ 4'-0โ 12โ x 6โ 12โ 950 PLF 6'-0โ 12โ x 8โ 12โ 1150 PLF 8'-0โ 12โ x 10โ 18โ 1300 PLF 10'-0โ 12โ x 12โ 24โ 1300 PLF 14.7.4 NMAC 14 12'-0โ 12โ x 14โ 24โ 1200 PLF C. Concrete lintels. When an engineerโs drawing and seal is not provided for lintels, all concrete lintels shall conform to table 6 and have a minimum strength of 3000 psi. Table 6 CEB WALL CONCRETE LINTEL SCHEDULE MIN. 3000 psi Maximum Span Minimum depth* Reinforcing Maximum Capacity per linear foot Bearing length on earth wall Less than 6' - 0" 8โ 2 - # 4 1500 lbs. 12โ 6' - 0" to 10'- 0" 12โ 3 - # 5 1500 lbs. 18โ 11' - 0" to 16'- 0" 16โ 3 - # 6 1500 lbs. 24โ * SIZE Wall width X depth of lintel