NAC 584.2261

Location of milking stalls and bulk tank.

Year: 2026Length: 139 wordsOfficial source

Cite as Nev. Admin. Code Sec. 584.2261

1. No milking stall may be closer than 3 feet to the wall of a milkhouse. The stall must have a stub wall which extends at least 5 feet above the floor for protection against splashes. No equipment may be installed in the passageway leading to the stall except the milk pump and releaser. If equipment is located in the passageway, a 3-foot walkway must be maintained in that passageway. 2. The bulk tank in the room used for the cooling and storing of milk must be located at least 30 inches from the walls on both sides and the rear of the tank, and the outlet of the tank must be at least 36 inches from the closest wall. A bulk tank may be bulkheaded into the milkhouse if the tank is designed for this type of installation.