Ohio Admin. Code 3745-51-22

Rule 3745-51-22. Characteristic of corrosivity

Last amended: 2021Year: 2026Length: 187 wordsOfficial source
119.03 (A) A waste exhibits the characteristic of corrosivity if a representative sample of the waste has either of the following properties: (1) The waste is aqueous and has a pH less than or equal to two or greater than or equal to 12.5, as determined by a pH meter using method 9040C in "Test Methods for Evaluating Solid Waste, Physical/Chemical Methods" U.S. EPA publication SW-846. (2) The waste is a liquid and corrodes steel (SAE 1020) at a rate greater than 6.35 millimeters (0.25 inch) per year at a test temperature of fifty-five degrees Celsius (one hundred thirty degrees Fahrenheit) as determined by method 1110A in "Test Methods for Evaluating Solid Waste, Physical/Chemical Methods" U.S. EPA publication SW-846. (B) A waste that exhibits the characteristic of corrosivity has the EPA hazardous waste number of D002. [Comment: For dates of non-regulatory government publications, publications of recognized organizations and associations, federal rules, and federal statutory provisions referenced in this rule, see rule 3745-50-11 of the Administrative Code titled "Incorporated by reference."] Last updated September 29, 2021 at 8:44 AM Supplemental Information Authorized By: 3734.12 Amplifies: 3734.12 6/26/2021 10/31/2015