OAC 252:100-8-1.5
Stack height limitations
Cite as Okla. Admin. Code § 252:100-8-1.5
(a) Stack height exclusion. Air quality modeling or ambient impact evaluation shall exclude the
effect of that portion of the height of any stack which exceeds good engineering practice or the
effect of any other dispersion techniques.
(b) Determination of good engineering practice (GEP) stack height. GEP stack height shall
be the greater of:
(1) 65 meters, measured from the ground-level elevation at the base of the stack; or
(2) The height under either OAC 252:100-8-1.5(b)(2)(A) or (B):
(A) for stacks in existence on January 12, 1979 and for which the owner or
operator had obtained all applicable permits or approvals required under OAC
252:100-8 or 40 CFR Part 52, Hg = 2.5H, provided the owner or operator can
demonstrate that this equation was relied upon in establishing an emission
limitation;
(B) for all other stacks, Hg = H + 1.5L, where:
(i) Hg = good engineering practice stack height, measured from the
ground-level elevation at the base of the stack,
(ii) H = height of nearby structure(s) measured from the ground-level
elevation at the base of the stack,
(iii) L = lesser dimension (height or projected width) of nearby
structure(s), provided that the owner or operator may be required to verify
such GEP stack height by the use of a field study or fluid model as the
Executive Director shall determine; or
(3) The height demonstrated by a fluid model or a field study approved by the reviewing
agency, which ensures that the emissions from a stack do not result in excessive
12
concentrations of any air pollutant as a result of atmospheric downwash, wakes, or eddy
effects created by the source itself, nearby structures, or nearby terrain features.
(c) Nearby.
(1) For the formulae in OAC 252:100-8-1. 5(b)(2). A structure or terrain feature shall
be considered nearby if it is located within a distance of up to five times the lesser of the
height or the width of a structure, but not more than 0.5 miles (0.8 km).
(2) For demonstration in OAC 252:100-8-1. 5(b)(3).
(A) A structure or terrain feature shall be considered nearby if located at a
distance not greater than 0.5 mile (0.8 km), except that
(B) A portion of a terrain feature may be considered nearby if:
(i) It falls within a distance (not to exceed 2 miles) of up to 10 times the
maximum height (Ht) of the feature, and
(ii) At a distance of 0.5 mile, the height of such feature is at least 40 percent of the
GEP stack height determined by the formulae provided in OAC 252:100-8-
1.5(b)(2)(B) or 85.3 feet (26 meters), whichever is greater, as measured from the
base of the stack.
(3) Measurement of height of structure or terrain. The height of the structure or
terrain feature is measured from the ground-level elevation at the base of the stack.
(d) Excessive concentrations. When utilized for the purpose of determining GEP stack height
under OAC 252:100-8-1.5(b)(3), excessive concentrations shall be as follows:
(1) For sources seeking credit for stack height exceeding that calculated under OAC
252:100-8-1.5(b)(2), a maximum ground-level pollutant concentration from a stack due
in whole or part to downwash, wakes, and eddy effects produced by nearby structures or
nearby terrain features which is at least 40 percent in excess of the maximum
concentration experienced in the absence of such downwash, wakes, or eddy effects and
which, when combined with the impacts due to all sources, produces a concentration in
excess of ana national ambient air quality standard. For sources subject to the prevention
of significant deterioration program (Part 7 of this Subchapter or Federal 40 CFR 52.21),
the same criteria apply except that a concurrent exceedance of a prevention of significant
deterioration increment is experienced. In making demonstrations under this part, the
allowable emission rate shall conform to the new source performance standard that is
applicable to the source category unless the owner or operator can demonstrate that this
emission rate is infeasible. Where such demonstrations are approved by the Director, an
alternative emission rate shall be established in consultation with the owner or operator;
(2) For sources seeking credit after October l, 1983, for increases in existing stack heights
up to the heights established under OAC 252:100-8-1.5(b)(2) either:
(A) a maximum ground-level concentration due in whole or part to downwash,
wakes or eddy effects as specified in OAC 252:100-8-1.5(b)(2), except that the
emission rate specified by any applicable state implementation plan (or, in the
absence of such a limit, the actual emission rate) shall be used, or
(B) the actual presence of a local nuisance caused by the existing stack, as
determined by the Director; and
(3) For sources seeking credit after January 12, 1979 for a stack height determined under
OAC 252:100-8-1.5(b)(2) where the Director requires the use of a field study or fluid
model to verify GEP stack height, for sources seeking stack height credit after November
9, 1984 based on the aerodynamic influence of cooling towers, and for sources seeking
13
stack height credit after December 31, 1970 based on the aerodynamic influence of
structures not adequately represented by the formulae in OAC 252:100-8-1.5(b)(2), a
maximum ground-level concentration due in whole or part to downwash, wakes or eddy
effects that is at least 40 percent in excess of the maximum concentration experienced in
the absence of such downwash, wakes or eddy effects.
PART 9. MAJOR SOURCES AFFECTING NONATTAINMENT AREAS