OAC 252:606-6-90
Effluent monitoring where permit limitations are not required
Cite as Okla. Admin. Code § 252:606-6-90
Where the discharge is new or where the C95 concentration does not exhibit reasonable
potential and less than ten data points are available to characterize an effluent distribution, effluent
monitoring for a limited period may be required so that reasonable potential may be reevaluated.
(1) Existing discharges. C95(M) is determined according to Equation I-9. C95(M) is used in
place of C95 in the various reasonable potential equations, and if reasonable potential is
exhibited using C95(M), effluent monitoring is required as a permit condition. The monitoring
frequency must be sufficient to provide at least ten data points over a period of three months
to one year.
(2) New discharges. C95(M) is determined based on the estimated maximum effluent
concentration for a substance according to Equation I-9. If reasonable potential is exhibited
using C95(M), effluent monitoring is required as a permit condition in the same manner as for
existing discharges.