OAC 252:641-3-4
Soil profile description test method
Cite as Okla. Admin. Code § 252:641-3-4
(a) Test hole requirements. Test holes may be augered borings, continuous core borings, or
excavated pits.
(1) Borings. If borings are used, three test holes shall be placed in the proposed dispersal
site at the approximate corners of an isosceles triangle having two (2) sides fifty feet (50') long
and one side seventy-five feet (75') long. If the dispersal field will cover an area larger than ten
thousand square feet (10,000 ft2), then one additional test hole shall be used for each additional
five thousand square feet (5,000 ft2). Additional test holes shall not be placed within fifty feet
of any other test hole and shall be located between fifty to seventy-five feet (50-75') from one
8
of the other test holes. The DEQ may approve or require alternative configurations. Borings
shall allow for the classification of the soil in six-inch intervals and shall be bored to a
minimum depth of forty-eight inches (48") or until one of the following is encountered first:
(A) a layer that is impervious to boring;
(B) a six-inch interval classified as a Group 5 soil; or
(C) water saturated soil.
(2) Pits. If excavated pits are used, three (3) pits shall be placed in the proposed dispersal
site at the approximate corners of an isosceles triangle having two (2) sides fifty feet (50') long
and one side seventy-five feet (75') long. If the dispersal field will cover an area larger than ten
thousand square feet (10,000 ft2), then one additional test hole shall be used for each additional
five thousand square feet (5,000 ft2). Additional test holes shall not be placed within fifty feet
of any other test hole and shall be located between fifty to seventy-five feet (50'-75') from one
of the other test holes. The DEQ may approve or require alternative configurations. Pits shall:
(A) have a depth of a minimum of forty-eight inches (48"), unless rock or water saturated
soil is encountered at a shallower depth;
(B) be a minimum of thirty-six inches (36") wide and sixty inches (60") long; and
(C) have one end sloped or stepped to allow for entry.
(b) Identification of limiting layers. The shallowest limiting layer encountered in the test holes
shall be the limiting layer for the entire dispersal site. The following are considered limiting layers
and shall be identified by depth on DEQ Form 641-581SP, "Report for On-Site Sewage
Treatment:"
(1) a layer that is impervious to boring;
(2) a six-inch interval classified as a Group 5 soil; and
(3) water saturated soil.
(c) Verifying limiting layers using pits. Limiting layers may be verified using an excavated
pit. The results of the pit(s) shall override the results of borings completed in the same proposed
dispersal site.
(d) Classifying soil intervals. For each test hole, the soil group for each six-inch interval
between the surface and the bottom of the test hole shall be identified using the guidelines found
in the "DEQ/OSU Soil Classification Manual" and classified as one of the soil groups in Appendix
B.
(e) Determining the soil group for the separation range. The soil group for the separation
range establishes the required vertical separation between the dispersed effluent and the limiting
layer. The separation range consists of the three (3) six-inch intervals above the interval containing
a limiting layer or, if no limiting layer was identified, the separation range shall be the three (3)
six-inch intervals above the bottom of the test hole. To determine the soil group for the separation
range:
(1) Select the test hole in the dispersal site with the lowest clay content in the separation range;
and
(2) Identify and record the most prevalent soil group in the separation range for that test hole.
(f) Identifying dispersal field options. Based on the soil group identified in (e) of this Section,
use Appendix A, Figure 1 to identify suitable dispersal fields along with their minimum separations
distances from the limiting layer.
(g) Sizing the dispersal field(s). Each suitable dispersal field shall be sized as follows:
(1) Determining sizing range. Select the test hole in the dispersal site with the highest clay
9
content in the sizing range for the chosen dispersal field. The applicable sizing range for each
type of dispersal field is as follows:
(A) Conventional subsurface absorption fields. The sizing range for conventional
subsurface absorption fields is the three (3) six-inch intervals between twelve inches (12")
and thirty inches (30").
(B) Low pressure dosing fields. The sizing range for low pressure dosing fields is the
three (3) six-inch intervals between twelve inches (12") and thirty inches (30").
(C) ET/A fields. The sizing range for ET/A fields is the three (3) six-inch intervals
between twelve inches (12") and thirty inches (30").
(D) Shallow extended subsurface absorption fields. The sizing range for shallow
extended subsurface absorption fields is the three (3) six-inch intervals between six inches
(6") and twenty-four inches (24").
(E) Drip irrigation fields. The sizing range for drip irrigation fields is the three (3) six-
inch intervals between ground level and eighteen inches (18").
(F) Spray irrigation fields. The sizing range for spray irrigation fields is the three (3)
six-inch intervals between ground level and eighteen inches (18").
(2) Identifying soil group in sizing range. Determine the most prevalent soil group in the
sizing range for the test hole selected in (1) of this subsection;
(3) Sizing dispersal field. Based on the soil group identified in (2) of this subsection, size
the dispersal field using the charts in Appendix H, Figures 3 and 5-22; and
(4) Sizing additional dispersal field options. Repeat (1) through (3) of this subsection for
each dispersal field option.
(h) Information to be reported. After completion of the soil profile, the soil profiler shall
submit an accurate, completed DEQ Form 641-581SP to the local DEQ office.The following
information must be reported to DEQ on DEQ Form 641-581SP, "Report for On-Site Sewage
Treatment":
(1) Property owner's name(s);
(2) Address or finding directions for property;
(3) Legal description of property including block and lot number when available;
(4) Lot size in square feet or acres;
(5) Whether the system will be an individual or small public on-site sewage treatment system;
(6) The estimated or actual average daily flow for the system as certified on DEQ Form 641-
581 Cert "Certification Documentation Form";
(7) Whether the water supply for the property is public or private;
(8) The location of each test hole (identified from two fixed reference points);
(9) The soil group for each six-inch interval between ground level and the bottom of each test
hole in the proposed dispersal field;
(10) The depth and description of any soil impervious to boring or water saturated soil layer in
each test hole located in the proposed dispersal field;
(11) Depth of limiting layer for entire dispersal field;
(12) The test hole number used to identify the separation range and the soil group of the
separation range in the proposed dispersal field;
(13) For each suitable dispersal fields or system(s) identified provide the following:
(A) the test hole number used to determine the sizing range;
(B) the soil group of the sizing range; and
10
(C) the minimum sizing and installation criteria for the dispersal field or system;
(14) The name, signature and registration number of the person conducting the soil profile
description;
(15) The date the soil profile description was conducted; and
(16) Check box indicating whether or not dispersal field will be located in Zone 1 of a water
body protection area.
SUBCHAPTER 5. BUILDING SEWER AND COLLECTION SYSTEMS