OAC 310:257-11-6
Floor carpeting, restrictions and installation
Cite as Okla. Admin. Code § 310:257-11-6
(a) A floor covering such as carpeting or similar material may not be installed as a floor covering
in food preparation areas, walk-in refrigerators, warewashing areas, toilet room areas where
handwashing lavatories, toilets, and urinals are located, refuse storage rooms, or other areas
where the floor is subject to moisture, flushing, or spray cleaning methods.
(b) If carpeting is installed as a floor covering in areas other than those specified under (a) of this
Section, it shall be:
(1) Securely attached to the floor with a durable mastic, by using a stretch and tack method,
or by another method; and
(2) Installed tightly against the wall under the coving or installed away from the wall with a
space between the carpet and the wall and with the edges of the carpet secured by metal
stripping or some other means.
OAC 310:257
OKLAHOMA STATE DEPARTMENT OF HEALTH
Page | 109