OAC 310:257-9-47
Backflow prevention
Cite as Okla. Admin. Code § 310:257-9-47
(a) P Except as specified in (b) through (d) of this Section, a direct connection may not exist
between the sewage system and a drain originating from equipment in which food, portable
equipment, or utensils are placed.
(b) Subsection (a) of this Section does not apply to floor drains that originate in refrigerated
spaces that are constructed as an integral part of the building.
(c) If allowed by law, a warewashing machine may have a direct connection between its waste
outlet and a floor drain when the machine is located within 1.5 m (5 feet) of a trapped floor drain
and the machine outlet is connected to the inlet side of a properly vented floor drain trap.
(d) If allowed by law, a warewashing or culinary sink may have a direct connection.