Regl. 5293, art. 110-34(e)-725

REMOTE-CONTROL, SIGNALING CIRCUITS

Last amended: 1993Length: 102 wordsOfficial source

Cite as Reglamento Núm. 5293, Art. 110-34(e)-725

70-753 720-4, Conductors. Conductors shall not be smaller than No. 12 copper or equivalent. Conductors for appliance branch circuits supplying more than one appliance or appliance receptacle shall not be smaller than No. 10 copper or equivalent. 720-5. Lampholders. Standard lampholders having a rating of not less than 660 watts shall be used. 720-6. Receptacle Rating. Receptacles shall have a rating of not less than 15 amperes. 720-7. Receptacles Required. Receptacles of not less than 20-ampere rating shall be provided in kitchens, laundries, and other locations where portable appliances are likely to be used. 720-8. Overcurrent Protection. Overcurrent protection shall comply with
Regl. 5293, art. 110-34(e)-725: REMOTE-CONTROL, SIGNALING CIRCUITS | Justis AI