Regl. 5293, art. 110-3(b)

Resolución 2535: adopta el Código Eléctrico Nacional, versión 1993. (Sustituye el Anejo A del Reglamento 4435)

Last amended: 1993Length: 755 wordsOfficial source

Cite as Reglamento Núm. 5293, Art. 110-3(b)

(FPN No. 1): The word "block" as used in this article means a square or portion of a city, town, or village enclosed by streets and including the alleys so enclosed, but not any street. The word "premises" as used in this article means the land and buildings of a user located on the user side of the utility-user network point of demarcation. (FPN No. 2): The word "exposed" as used in this article means that the circuit is in such a position that, in case of failure of supports or insulation, contact with another circuit may result. (FPN No. 3): On a circuit not exposed to accidental contact with power conductors, providing a listed primary protector in accordance with this article will help protect against other hazards, such as lightning and above-normal voltages induced by fault currents on power circuits in proximity to the communications circuit. (FPN No. 4): Interbuilding circuits are considered to have a lightning exposure unless one or more of the following conditions exist: 1. Circuits in large metropolitan areas where buildings are close together and sufficiently high to intercept lightning. 2. Interbuilding cable runs of 140 feet (42.7 m) or less, directly buried or in underground conduit, where a continuous metallic cable shield or a continuous metallic conduit containing the cable is bonded to each building grounding electrode system. 3. Areas having an average of five or fewer thunderstorm days per year and earth resistivity of less than 100 ohm-meters. Such areas are found along the Pacific coast. (1) Fuseless Primary Protectors. Fuseless-type primary protectors shall be permitted under any of the following conditions: a. Where conductors enter a building through a cable with grounded metallic sheath member(s) and if the conductors in the cable safely fuse on all currents greater than the current-carrying capacity of the primary protector and of the primary protector grounding conductor. ARTICLE 800 - COMMUNICATIONS CIRCUITS 70-795 b. Where insulated conductors in accordance with Section 800-12(a) are used to extend circuits to a building from a cable with effectively grounded metallic sheath member(s) and if the conductors in the cable or cable stub, or the connections between the insulated conductors and the exposed plant, safely fuse on all currents greater than the current-carrying capacity of the primary protector, or the associated insulated conductors and of the primary protector grounding conductor. c. Where insulated conductors in accordance with Section 800-12(a) or (b) are used to extend circuits to a building from other than a cable with metallic sheath member(s) if (1) the primary protector is listed for this purpose, and (2) the connections of the insulated conductors to the exposed plant or the conductors of the exposed plant safely fuse on all currents greater than the current-carrying capacity of the primary protector, or the associated insulated conductors and of the primary protector grounding conductor. d. Where insulated conductors in accordance with Section 800-12(a) are used to extend circuits aerially to a building from an unexposed buried or underground circuit. e. Where insulated conductors in accordance with Section 800-12(a) are used to extend circuits to a building from cable with effectively grounded metallic sheath member(s) and if (1) the combination of the primary protector and insulated conductors is listed for this purpose, and (2) the insulated conductors safely fuse on all currents greater than the current-carrying capacity of the primary protector and of the primary protector grounding conductor. (FPN): Effectively grounded means intentionally connected to earth through a ground connection or connections of sufficiently low impedance and having sufficient current-carrying capacity to prevent the buildup of voltages that may result in undue hazard to connected equipment or to persons. (2) Fused Primary Protectors. Where the requirements listed under items a through e above are not met, fused-type primary protectors shall be used. Fused-type primary protectors shall consist of an arrester connected between each line conductor and ground, a fuse in series with each line conductor, and an appropriate mounting arrangement. Primary protector terminals shall be marked to indicate line, instrument, and ground, as applicable. (b) Location. The primary protector shall be located in, on, or immediately adjacent to the structure or building served and as close as practicable to the point at which the exposed conductors enter or attach. For purposes of this section, the point at which the exposed conductors enter shall be considered to be the point of emergence through an exterior wall, a concrete floor slab, or from a rigid metal conduit or an intermediate metal conduit grounded to an electrode in accordance with
Regl. 5293, art. 110-3(b): Resolución 2535: adopta el Código Eléctrico Nacional, versión 1993. (Sustituye el Anejo A del Reglamento 4435) | Justis AI