Regl. 5293, art. 501-6(b)-511
COMMERCIAL GARAGES,
Cite as Reglamento Núm. 5293, Art. 501-6(b)-511
REPAIR AND STORAGE
511-1. Scope. These occupancies shall include locations used for service
and repair operations in connection with self-propelled vehicles (including
passenger automobiles, buses, trucks, tractors, etc.) in which volatile flammable liquids are used for fuel or power.
511-2. Locations. Areas in which flammable fuel is transferred to vehicle
fuel tanks shall conform to Article 514. Parking garages used for parking or
storage and where no repair work is done except exchange of parts and
routine maintenance requiring no use of electrical equipment, open flame,
welding, or the use of volatile flammable liquids are not classified, but they
shall be adequately ventilated to carry off the exhaust fumes of the
engines.
(FPN): For further information, see Parking Structures, NFPA 88A-1991, and
Repair Garages, NFPA 88B-1991.
511-3. Class I Locations. Classification under Article 500.
(a) Up to a Level of 18 Inches (457 mm) Above the Floor. For each
floor, the entire area up to a level of 18 inches (457 mm) above the floor
shall be considered to be a Class I, Division 2 location except where the
enforcing agency determines that there is mechanical ventilation providing
a minimum of four air changes per hour.
(b) Any Pit or Depression Below Floor Level. Any pit or depression
below floor level shall be considered to be a Class I, Division 1 location
which shall extend up to said floor level, except that any pit or depression
in which six air changes per hour are exhausted at the floor level of the pit
shall be permitted to be judged by the enforcing agency to be a Class I,
Division 2 location.
Exception: Lubrication and service rooms without dispensing shall be
classified in accordance with Table 514-2.
(c) Areas Adjacent to Defined Locations or with Positive Pressure Ventilation. Areas adjacent to defined locations in which flammable vapors are
not likely to be released, such as stock rooms, switchboard rooms, and
70-504
NATIONAL ELECTRICAL CODE
other similar locations, shall not be classified where mechanically ventilated at a rate of four or more air changes per hour or where effectively cut
off by walls or partitions.
(d) Adjacent Areas by Special Permission. Adjacent areas that by reason of ventilation, air pressure differentials, or physical spacing are such
that, in the opinion of the authority enforcing this Code, no ignition hazard
exists shall be classified as nonhazardous.
(e) Fuel Dispensing Units. Where fuel dispensing units (other than liquid petroleum gas, which is prohibited) are located within buildings, the
requirements of Article 514 shall govern.
Where mechanical ventilation is provided in the dispensing area, the
controls shall be interlocked so that the dispenser cannot operate without
ventilation as prescribed in Section 500-5(b).
(f) Portable Lighting Equipment. Portable lighting equipment shall be
equipped with handle, lampholder, hook, and substantial guard attached to
the lampholder or handle. All exterior surfaces that might come in contact
with battery terminals, wiring terminals, or other objects shall be of nonconducting material or shall be effectively protected with insulation. Lampholders shall be of unswitched type and shall not provide means for plug-in
of attachment plugs. The outer shell shall be of molded composition or
other suitable material. Unless the lamp and its cord are supported or
arranged in such a manner that they cannot be used in the locations classified in Section 511-3, they shall be of a type approved for Class I, Division 1 locations.
511-4. Wiring and Equipment in Class I Locations. Within Class I locations as defined in Section 511-3, wiring and equipment shall conform to
applicable provisions of Article 501. Raceways embedded in a masonry
wall or buried beneath a floor shall be considered to be within the Class I
location above the floor if any connections or extensions lead into or
through such areas.
511-5. Sealing. Approved seals conforming to the requirements of Section 501-5 shall be provided, and Section 501-5(b)(2) shall apply to horizontal as well as vertical boundaries of the defined Class I locations.
511-6. Wiring in Spaces Above Class I Locations.
(a) Fixed Wiring Above Class I Locations. All fixed wiring above Class
I locations shall be in metal raceways, rigid nonmetallic conduit, electrical
nonmetallic tubing, flexible metal conduit, liquidtight flexible metal conduit, or liquidtight flexible nonmetallic conduit or shall be Type MC, MI,
manufactured wiring systems, SNM, or PLTC cable in accordance with