Regl. 5293, art. 520-44(a)-31

0, Note 3 of Notes to Ampacity Tables of 0 to 2000 Volts shall

Last amended: 1993Length: 126 wordsOfficial source

Cite as Reglamento Núm. 5293, Art. 520-44(a)-31

be permitted. 550-23. Mobile Home Service Equipment. (a) Service Equipment. The mobile home service equipment shall be located adjacent to the mobile home and not mounted in or on the mobile home. The service equipment shall be located in sight from and not more than 30 feet (9.14 m) from the exterior wall of the mobile home it serves. Exception No. 1: The service equipment shall be permitted to be located elsewhere on the premises, provided that all of the following conditions are met: a. A disconnecting means suitable for service equipment is located in sight from and not more than 30 feet (9.14 m) from the exterior wall of the mobile home it serves. b. Grounding at the disconnecting means shall be in accordance with