Regl. 1277, art. 111.1a
Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005
Cite as Reglamento Núm. 1277, Art. 111.1a
Hoistway doors shall be equipped with
hoistway unit system hoistway-door interlocks.
111. 1b - For power freight elevators. The hoistway doors will be provided with an interlock
hoistway unit system.
Exceptions
(1) Hoistway-unit system combination mechanical locks and electric contacts may be used for
manually opened vertically sliding counterweighted or vertically sliding biparting counterbalanced
doors under the following conditions:
(a) Elevators with a travel of fifteen
(15) feet or less. For the top
landing door and for any door
whose sill is located not more
than four (4) feet below the
sill of the top landing door.
(b) Elevators with any travel.
For any door whose sill is within
five (5) feet of the bottom of
the pit.
(2) Combination mechanical locks and electric
contacts may be used on the door at the
bottom landing of sidewalk elevators
(See Part IV, Section 401, Rule 401.5b)