Regl. 1277, art. 111.1c

Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005

Last amended: 2005Length: 92 wordsOfficial source

Cite as Reglamento Núm. 1277, Art. 111.1c

Hoistway doors shall be provided with hoistway unit system hoistway door combination mechanical locks and electric contacts. Exception: Hoistway door interlocks shall be provided at landings where the bottom of the door opening is less than twenty four (24) inches above the floor other than the followings: (1) Undercounter dumbwaiters (2) **Dumbwaiters not accesible to the general public where the load is handled on wheel trucks. (3) At landings where the landing sill is within five (5) feet of the bottom of the pit. 111.1d - For Hand Elevators and Hand Dumbwaiters
Regl. 1277, art. 111.1c: Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005 | Justis AI