Regl. 1277, art. 111.3

Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005

Last amended: 2005Length: 106 wordsOfficial source

Cite as Reglamento Núm. 1277, Art. 111.3

111.3a - Operation of the Driving Machine with a 111.3a hoistway door unlocked or not in the close position. Operation of the driving machine when a hoistway door is unlocked or not in the closed position (See Rule 111.8) is permissible under the following conditions: 1. By a car-leveling or truck-zoning device (See Part II, Section 210, Rule 210.1e). 2. By a combination hoistway access switch and operating device (See Rule 111.10). 3. When a hoistway access switch is operated (See Rule 111.10). 19 - TEXTO EN ESPAÑOL puertas de corredera horizontales o de vaivên (Vea Sección 110, Regla 110.5) serán provistas con inmovilizadores mecánicos independientes.
Regl. 1277, art. 111.3: Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005 | Justis AI