Regl. 6302, art. 405(b)(9)-5 dup2

of this specification: and was determined to be

Length: 600 wordsOfficial source

Cite as Reglamento Núm. 6302, Art. 405(b)(9)-5 dup2

acceptable under MIL-STD-105D procedures, acceptable quality level 1.0. The certificate of conformance must include the results of each test performed for the analyzer(s) sampled during the month the analyzer being installed was produced. 7. Performance Specification Verification Procedure Test each CEMS that conforms to the design specifications (Section 5.1) using the following procedures to determine conformance with the specifications of Table 1- 1. These tests are to be performed using the data recording system to be employed during monitoring. Prior approval from the Administrator is required if different data recording systems are used during the performance test and monitoring. 7.1 Preliminary Adjustments and Tests. Before installing the system on the stack, perform these steps or tests at the affected facility or in the manufacturer's laboratory. 7.1.1 Equipment Preparation. Set up and calibrate the CEMS for the monitor path length to be used in the installation as specified by the manufacturer's written instructions. For this specification, the mounting distance between the transmitter and receiver/reflector unit at the source must be measured prior to performing the calibrations (do not use distances from engineering drawings). If the CEMS has automatic path length adjustment, follow the manufacturer's instructions to adjust the signal output from the analyzer in order to yield results based on the emission outlet path length. Set the instrument and data recording system ranges so that maximum instrument output is within the span range specified in the applicable subpart. Align the instrument so that maximum system response is obtained during a zero (or upscale) check performed across the simulated monitor path length. As part of this alignment. include rotating the reflector unit (detector unit for single pass instruments) on its axis until the point of maximum instrument response is obtained. Follow the manufacturer's instructions to zero and span the instrument. Perform the zero alignment adjustment by balancing the response of the CEMS so that the simulated zero check coincides with the actual zero check performed across the simulated monitor path length. At this time. measure and record the indicated upscale calibration value. The calibration value reading must be within the required opacity range (Section 3.3). 7.1.2 Calibration Attenuator Selection. Based on the span value specified in the applicable subpart, select a minimum of three calibration attenuators (low, mid, and high range) using Table 1-2. If the system is operating with automatic path length compensation, calculate the attenuator values required to obtain a system response equivalent to the applicable values shown in Table 1-2; use Equation 1-1 for the conversion. A series of filters with nominal optical density (opacity) values of 0.1(20). 0.2(37), 0.3(50), 0.4(60), 0.5(68). 0.6(75), 0.7(80), 0.8(84), 0.9(88), and 1.0(90) are commercially available. Within this limitation of filter availability. select the calibration attenuators having the values given in Table 1-2 or having values closest to those calculated by Equation 1-1. D₁=D₂ (L₁/L₂) Eq. I-I TABLE 1-2-REQUIRED CALIBRATION ATTENUATOR VALUES (NOMINAL) Calibrated attenuator optical density Span value (percent (equivatent opacity in parenthesis)- opacity) D2 Low-range Mid-range High-range 40 0.05 (11) 0.1 (20) 0.2 (37) 50 0.1 (20) 0.2 (37) 0.3 (50) 60 0.1 (20) 0.2 (37) 0.3 (50) 70 0.1 (20) 0.3 (50) 0.4 (60) 80 0.1 (20) 0.3 (50) 0.6 (75) 90 0.1 (20) 0.4 (60) 0.7 (80) 100 0.1 (20) 0.4 (60) 0.9 (87.5) Where: D1=Nominal optical density value of required mid, low, or high range calibration attenuators. D₂=Desired attenuator optical density output value from Table 1-2 at the span required by the applicable subpart. Pt. 60, App. B, Spec. 1 L₁=Monitor path length. L₂=Emission outlet path length. 7.1.3 Attenuator Calibration. Select a laboratory calibration spectrophotometer meeting the specifications of
Regl. 6302, art. 405(b)(9)-5 dup2: of this specification: and was determined to be | Justis AI