Regl. 6303, art. 7.1

5, select the value of Cₛ that corresponds to the peak area.

Length: 2,562 wordsOfficial source

Cite as Reglamento Núm. 6303, Art. 7.1

Calculate the concentration Cc in ppm, dry basis, of each organic in the sample as follows: EMTIC M-18 EMTIC NSPS Test Method Page 12 7.1.1.1.6 Flowmeter. 0 to 500-ml flow range; with manufacturer's calibration curve. 7.1.1.2 Sampling Procedure. To obtain a sample, assemble the sample train as shown in Figure 18-9. Leak check both the bag and the container. Connect the vacuum line from the needle valve to the Teflon sample line from the probe. Place the end of the probe at the centroid of the stack or at a point no closer to the walls than 1 m, and start the pump with the needle valve adjusted to yield a flow of 0.5 liter/minute. After allowing sufficient time to purge the line several times, connect the vacuum line to the bag, and evacuate until the rotameter indicates no flow. Then position the sample and vacuum lines for sampling, and begin the actual sampling, keeping the rate proportional to the stack velocity. As a precaution, direct the gas exiting the rotameter away from sampling personnel. At the end of the sample period, shut off the pump, disconnect the sample line from the bag, and disconnect the vacuum line from the bag container. Record the source temperature, barometric pressure, ambient temperature, sampling flow rate, and initial and final sampling time on the data sheet shown in Figure 18-10. Protect the Tedlar bag and its container from sunlight. When possible, perform the analysis within 2 hours of sample collection. 7.1.2 Direct Pump Sampling Procedure. Follow 7.1.1, except place the pump and needle valve between the probe and the bag. Use a pump and needle valve constructed of stainless steel or some other material not affected by the stack gas. Leak-check the system, and then purge with stack gas before connecting to the previously evacuated bag. 7.1.3 Explosion Risk Area Bag Sampling Procedure. Follow 7.1.1 except replace the pump with another evacuated can (see Figure 18-9a). Use this method whenever there is a possibility of an explosion due to pumps, heated probes, or other flame producing equipment. 7.1.4 Other Modified Bag Sampling Procedures. In the event that condensation is observed in the bag while collecting the sample and a direct interface system cannot be used, heat the bag during collection, and maintain it at a suitably elevated temperature during all subsequent operations. (NOTE: Take care to leak-check the system prior to the dilutions so as not to create a potentially explosive atmosphere.) As an alternative, collect the sample gas, and simultaneously dilute it in the Tedlar bag. In the first procedure, heat the box containing the sample bag to the source temperature, provided the components of the bag and the surrounding box can withstand this temperature. Then transport the bag as rapidly as possible to the analytical area while maintaining the heating, or cover the box with an insulating blanket. In the analytical area, keep the box heated to source temperature until analysis. Be sure that the method of heating the box and the control for the heating circuit are compatible with the safety restrictions required in each area. To use the second procedure, prefill the Tedlar bag with a known quantity of inert gas. Meter the inert gas into the bag according to the procedure for the preparation of gas concentration standards of volatile liquid materials (Section 6.2.2.2), but eliminate the midget impinger section. Take the partly filled bag to the source, and meter the source gas into the bag through heated sampling lines and a heated flowmeter, or Teflon positive displacement pump. Verify the dilution factors periodically through dilution and analysis of gases of known EMTIC M-18 EMTIC NSPS Test Method Page 11 tester may obtain audit cylinders by contacting: U.S. Environmental Protection Agency, Environmental Monitoring Systems Laboratory, Quality Assurance Division (MD-77), Research Triangle Park, North Carolina 27711. Audit cylinders obtained from a commercial gas manufacturer may be used provided that (a) the gas manufacturer certifies the audit cylinder in a manner similar to the procedure described in 40 CFR Part 61, Appendix B, Method 106, Section 5.2.3.1, and (b) the gas manufacturer obtains an independent analysis of the audit cylinders to verify this analysis. Independent analysis is defined as an analysis performed by an individual other than the individual who performs the gas manufacturer's analysis, while using calibration standards and analysis equipment different from those used for the gas manufacturer's analysis. Verification is complete and acceptable when the independent analysis concentration is within 5 percent of the gas manufacturer's concentration. 7. FINAL SAMPLING AND ANALYSIS PROCEDURE Considering safety (flame hazards) and the source conditions, select an appropriate sampling and analysis procedure (Section 7.1, 7.2, 7.3 or 7.4). In situations where a hydrogen flame is a hazard and no intrinsically safe GC is suitable, use the flexible bag collection technique or an adsorption technique. If the source temperature is below 100°C, and the organic concentrations are suitable for the detector to be used, use the direct interface method. If the source gases require dilution, use a dilution interface and either the bag sample or adsorption tubes. The choice between these two techniques will depend on the physical layout of the site, the source temperature, and the storage stability of the compounds if collected in the bag. Sample polar compounds by direct interfacing or dilution interfacing to prevent sample loss by adsorption on the bag. 7.1 Integrated Bag Sampling and Analysis. 7.1.1 Evacuated Container Sampling Procedure. In this procedure, the bags are filled by evacuating the rigid air-tight container holding the bags. Use a field sample data sheet as shown in Figure 18-10. Collect triplicate sample from each sample location. 7.1.1.1 Apparatus. 7.1.1.1.1 Probe. Stainless steel, Pyrex glass, or Teflon tubing probe, according to the duct temperature, with 6.4-mm OD Teflon tubing of sufficient length to connect to the sample bag. Use stainless steel or Teflon unions to connect probe and sample line. 7.1.1.1.2 Quick Connects. Male (2) and female (2) of stainless steel construction. 7.1.1.1.3 Needle Valve. To control gas flow. 7.1.1.1.4 Pump. Leakless Teflon-coated diaphragm-type pump or equivalent. To deliver at least 1 liter/min. 7.1.1.1.5 Charcoal Adsorption Tube. Tube filled with activated charcoal, with glass wool plugs at each end, to adsorb organic vapors. EMTIC M-18 EMTIC NSPS Test Method Page 10 20°C may be used. Calculate each organic standard concentration, Cₛ in ppm as follows: L (24.055x106) C₈ = =6.24x10⁴ LVPTₘ 293 Pₘ Y 1000 MVₘYPₘ Eq. 18-4 760 where: Lv = Liquid volume of organic injected, µl = Liquid organic density as determined, g/ml. M = Molecular weight of organic, g/g-mole. 24.055 = Ideal gas molar volume at 293 °K and 760 mm Hg, liters/g-mole. 10⁶ = conversion to ppm. 1000 = Conversion factor, µl/ml. 6.3 Preparation of Calibration Curves. Establish proper GC conditions, then flush the sampling loop for 30 seconds at a rate of 100 ml/min. Allow the sample loop pressure to equilibrate to atmospheric pressure, and activate the injection valve. Record the standard concentration, attenuator factor, injection time, chart speed, retention time, peak area, sample loop temperature, column temperature, and carrier gas flow rate. Repeat the standard injection until two consecutive injections give area counts within 5 percent of their average. The average value multiplied by the attenuator factor is then the calibration area value for the concentration. Repeat this procedure for each standard. Prepare a graphical plot of concentration (Cₛ) versus the calibration area values. Perform a regression analysis, and draw the least square line. 6.4 Relative Response Factors. The calibration curve generated from the standards for a single organic can usually be related to each of the individual GC response curves that are developed in the laboratory for all the compounds in the source. In the field, standards for that single organic can then be used to "calibrate" the GC for all the organics present. This procedure should first be confirmed in the laboratory by preparing and analyzing calibration standards containing multiple organic compounds. 6.5 Quality Assurance for Laboratory Procedures. Immediately after the preparation of the calibration curves and prior to the presurvey sample analysis, the analysis audit described in 40 CFR Part 61, Appendix C, Procedure 2: "Procedure for Field Auditing GC Analysis," " should be performed. The information required to document the analysis of the audit samples has been included on the example data sheets shown in Figures 18-3 and 18-7. the audit analyses should agree with the audit concentrations within 10 percent. When available, the EMTIC M-18 EMTIC NSPS Test Method Page 9 where: Gv = Gas volume or organic compound injected, ml. 10⁶ = Conversion to ppm. Pₛ = Absolute pressure of syringe before injection, mm Hg. Ts = Absolute temperature of syringe before injection, °K. Vₘ = Gas volume indicated by dry gas meter, liters. Y = Dry gas meter calibration factor, dimensionless. Pₘ = Absolute pressure of dry gas meter, mm Hg. Tₘ = Absolute temperature of dry gas meter, °K. 1000 = Conversion factor, ml/liter. 6.2.2.2 Liquid Injection Technique. Use the equipment shown in Figure 18-8. Calibrate the dry gas meter as described in Section 6.2.2.1 with a set test meter or a spirometer. Use a water manometer for the pressure gauge and glass, Teflon, brass, or stainless steel for all connections. Connect a valve to the inlet of the 50-liter Tedlar bag. To prepare the standards, assemble the equipment as shown in Figure 18-8, and leak-check the system. Completely evacuate the bag. Fill the bag with hydrocarbon-free air, and evacuate the bag again. Close the inlet valve. Turn on the hot plate, and allow the water to reach boiling. Connect the bag to the impinger outlet. Record the initial meter reading, open the bag inlet valve, and open the cylinder. Adjust the rate so that the bag will be completely filled in approximately 15 minutes. Record meter pressure and temperature, and local barometric pressure. Allow the liquid organic to equilibrate to room temperature. Fill the 1.0- or 10-microliter syringe to the desired liquid volume with the organic. Place the syringe needle into the impinger inlet using the septum provided, and inject the liquid into the flowing air stream. Use a needle of sufficient length to permit injection of the liquid below the air inlet branch of the tee. Remove the syringe. When the bag is filled, stop the pump, and close the bag inlet valve. Record the final meter reading, temperature, and pressure. Disconnect the bag from the impinger outlet, and either set it aside for at least 1 hour, or massage the bag to insure complete mixing. Measure the solvent liquid density at room temperature by accurately weighing a known volume of the material on an analytical balance to the nearest 1.0 milligram. A ground-glass stoppered 25-ml volumetric flask or a glass-stoppered specific gravity bottle is suitable for weighing. Calculate the result in terms of g/ml. As an alternative, literature values of the density of the liquid at EMTIC M-18 EMTIC NSPS Test Method Page 8 Eq. 18-2 where: 106 = Conversion to ppm. X = Mole or volume fraction of the organic in the calibration gas to be diluted. qc1 = Flow rate of the calibration gas to be diluted in stage 1. 9c2 = Flow rate of the calibration gas to be diluted in stage 2. qd1 = Flow rate of diluent gas in stage 1. qd2 = Flow rate of diluent gas in stage 2. Further details of the calibration methods for flowmeters and the dilution system can be found in Citation 21 in the Bibliography. 6.2.2 Preparation of Standards from Volatile Materials. Record all data shown on Figure 18-3. 6.2.2.1 Gas Injection Technique. This procedure is applicable to organic compounds that exist entirely as a gas at ambient conditions. Evacuate a 10- liter Tedlar bag that has passed a leak-check (see Section 7.1), and meter in 5.0 liters of air or nitrogen through a dry gas meter that has been calibrated in a manner consistent with the procedure described in Section 5.1.1 of Method 5. While the bag is filling use a 0.5-ml syringe to inject a known quantity of "pure" gas of the organic compound through the wall of the bag, or through a septum-capped tee at the bag inlet. Withdraw the syringe needle, and immediately cover the resulting hole with a piece of masking tape. In a like manner, prepare dilutions having other concentrations. Prepare a minimum of three concentrations. Prepare a minimum of three concentrations. Place each bag on a smooth surface, and alternately depress opposite sides of the bag 50 times to mix the gases. Record the average meter temperature and pressure, the gas volume and the barometric pressure. Record the syringe temperature and pressure before injection. Calculate each organic- standard concentration Cₛ in ppm as follows: 293 P₈ = G, Y x 293 10⁶ 760 Ts Pₘ 760 1000 Eq. 18-3 = Vₘ Y EMTIC M-18 EMTIC NSPS Test Method Page 7 procedures. 6.2.1 Preparation of Standards from High Concentration Cylinder Standards. Obtain enough high concentration cylinder standards to represent all the organic compounds expected in the source samples. Use these high concentration standards to prepare lower concentration standards by dilution, as shown by Figures 18-5 and 18-6. To prepare the diluted calibration samples, calibrated rotameters are normally used to meter both the high concentration calibration gas and the diluent gas. Other types of flowmeters and commercially available dilution systems can also be used. Calibrate each flowmeter before use by placing it between the diluent gas supply and suitably sized bubble meter, spirometer, or wet test meter. Record all data shown on Figure 18-4. While it is desirable to calibrate the cylinder gas flowmeter with cylinder gas, the available quantity and cost may preclude it. The error introduced by using the diluent gas for calibration is insignificant for gas mixtures of up to 1,000 to 2,000 ppm of each organic component. Once the flowmeters are calibrated, connect the flowmeters to the calibration and diluent gas supplies using 6-mm Teflon tubing. Connect the outlet side of the flowmeters through a connector to a leak-free Tedlar bag as shown in Figure 18-5. (See Section 7.1 for bag leak-check procedures.) Adjust the gas flow to provide the desired dilution, and fill the bag with sufficient gas for GC calibration. Be careful not to overfill and cause the bag to apply additional pressure on the dilution system. Record the flow rates of both flowmeters, and the laboratory temperature and atmospheric pressure. Calculate the concentration Cs in ppm of each organic in the diluted gas as follows: Cₛ = 10⁶ qc (X + qd qc) Eq. 18-1 where: 10⁶ = Conversion to ppm. X = Mole or volume fraction of the organic in the calibration gas to be diluted. qc = Flow rate of the calibration gas to be diluted. qd = Diluent gas flow rate. Single-stage dilutions should be used to prepare calibration mixtures up to about 1:20 dilution factor. For greater dilutions, a double dilution system is recommended, as shown in Figure 18-6. Fill the Tedlar bag with the dilute gas from the second stage. Record the laboratory temperature, barometric pressure, and static pressure readings. Correct the flow reading for temperature and pressure. Calculate the concentration C₈ in ppm of the organic in the final gas mixture as follows: EMTIC M-18 EMTIC NSPS Test Method Page 6 analytical procedures. 6.1.2 Preliminary GC Adjustment. Using the standards and column obtained in
Regl. 6303, art. 7.1: 5, select the value of Cₛ that corresponds to the peak area. | Justis AI