Regl. 2438, art. 1926.750
Temporary Flooring: Skeleton
Cite as Reglamento Núm. 2438, Art. 1926.750
Steel Construction in Tiered Buildings as it
apppears published in Federal Register, Volume 39
Number 128 of July 2, 1974
1910 and 1926 - Recodification of Air Contaminant
Standards as it appears published in Federal Register
Volume 40, Number 107 of June 3, 1975
This adoption will be effective immediately after its
approval.
Given on this
9
of
October
Carll of 1978.
DEL
DEPARTMENT RECURSOS NTO TRADAD 00
Carlos S. Quirós
23847
CHAPTER XVII-OCCUPATIONAL SAFETY
AND HEALTH ADMINISTRATION, DE-
PARTMENT OF LABOR
Title 29-Labor
PART 1910-OCCUPATIONAL SAFETY
AND HEALTH STANDARDS
PART 1926-SAFETY AND HEALTH
REGULATIONS FOR CONSTRUCTION
Recodification of Air Contaminant
Standards
Correction
In FR Doc. 75-13809 appearing at page
23072, in the issue of Wednesday, May 28,
1975, in the third column on this page
23072, immediately after the fourteenth
line of the first complete paragraph insert the following: "with toxic substances
will be placed in".
FEDERAL REGISTER, VOL. 40, NO. 107-TUESDAY, JUNE 3, 1975
ments suggest th
The use of safety nets
be permitted as an alternative to the
installation of temporary floors.
In summary, the comments appear to
agree that employees engaged in skeleton steel erection should be protected
by the standard regardless of the equipment being used or the work activity
involved. Several persons recommend
the adoption of pertinent provisions of
ANSI Standard A10.13-1972, Safety Requirements for Steel Erection, covering
work operations involved in skeleton
steel erection, including the removal of
temporary floors. Also a few comments
suggest that parallel changes be made
24360
in $ 1926.750(b) (1) (ii) and § 1926.105
(a), It is argued that the proposal con-
Title 29-Labor
flicts with the 25-foot-height require-
CHAPTER XVII-OCCUPATIONAL SAFETY
ments in these two sections which in-
AND HEALTH ADMINISTRATION, DEvolve work places and potential fall dis-
PARTMENT OF LABOR
tances similar to those covered by the
proposal.
PART 1926-SAFETY AND HEALTH
REGULATIONS FOR CONSTRUCTION
Only three comments oppose the proposal. The objectors allege that the adop-
Temporary Flooring; Skeleton Steel
tion of the proposal would expose em-
Construction in Tiered Buildings
ployees to a greater risk of injury as a
On January 16, 1974, a notice was pubresult of a potential fall distance of 30
lished in the FEDERAL REGISTER (39 FR
feet, while the present standard allow's
2015) of a proposal to revise 29 CFR
a maximum fall distance of 25 feet. One
1926.750(b) (2) to require that where
comment contends that the proposal is
erection is being done by means of a
less stringent than codes or rules of some
crane operating on the ground, a tight
states and safety organizations.
and substantial floor be maintained
After careful consideration of the iswithin two stories or 30 feet, whichever
sues raised by the written comments. it is
is less, below and directly under that
concluded that the proposed amendment
portion of each tier of beams on which
should be adopted with modifications.
bolting, riveting, welding, or painting is
The contention that the coverage and
being done. The reason for the proposal
application of the standard is too rewas to allow for current designs in steel
strictive has merit. It is agreed that the
erection which involve the use of a
falling hazards to employees engaged in
greater depth of structural beam memsteel erection are similar regardless of
bers. The proposal was substantially
the type of equipment being used or the
based on the recommendations of the
work activity being performed. Further,
Advisory Committee on Construction
it is agreed that provisions covering the
Safety and Health.
removal of temporary floors are neces-
The notice invited interested persons
sary for the protection of employees. Accordingly, it has been decided to amend
to submit written data, views, and argu-
$ 1926.750(b) (2) in substantial conformments concerning the proposal. Interested persons were also afforded an
ity with a pertinent paragraph of ANSI
A10.13-1972, Safety Requirements for
opportunity to file objections to the proposed revision and to request a hearing
Steel Erection. Two closely similar paraon the objections. Many written comgraphs of the ANSI standard have been
pointed out. Both require some form of
ments were received in response to the
notice. The majority of the comments
protection "within two floors or 30 feet,
whichever is less
below a tier of
supported the adoption of the proposal
with some suggestions for changes. Sevbeams on which work is done. Both proeral objections to the adoption of the
vide expressly for the removal of planks.
proposal were received. However, no
However, $ 6.2 of the ANSI Standard rehearing has been requested.
quires a tight and substantial floor when
bolting, riveting, or welding is done, while
Several comments contend that the
§ 10.1.2 of the same standard requires "a
scope and application of the proposal is
floor or safety nets" for "any work,"
not broad enough to provide adequate
presumably any work other than bolting,
protection for all employees engaged in
riveting. or welding. The amended
skeleton steel construction. It is con-
§ 1926.750(b) (2) follows $ 6.2 of the ANSI
tended that the proposal does not cover
Standard, in requiring a substantial floor,
steel erection using derricks or tower
but expands the requirement to apply to
cranes, or cranes which are not operated
any work. When bolting, riveting, or
from the ground. Also, some comments
welding is done, a substantial floor is
state that the reference in the proposal
more appropriate than a safety net.
to bolting, riveting, welding or painting
Such a floor stops falling rivets, bolts,
operations unnecessarily excludes all
tools, and molten slag, and its planks
other operations or work activities involved in skeleton steel erection. Furare not cut, burned, or otherwise damther, it is pointed out that the proposal
aged as easily as the ropes of a safety
does not contain provisions for the renet. Also, a floor permits some work to be
moval of temporary floors. Some comperformed by employees while standing
EDERAL REGISTER, VOL. 39, NO. 128-TUESDAY, JULY 2, 1974
24361
RULES AND REGULATIONS
on the floor. Finally, a floor requirement
§