Regl. 1277, art. 111.6b-111.6b

Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005

Last amended: 2005Length: 135 wordsOfficial source

Cite as Reglamento Núm. 1277, Art. 111.6b-111.6b

111.6b Aprobación, Inspección y Pruebas. Cada tipo y modelo de inmovilizador para puertas de pozo, combinación de enclavador mecânico y - 32 - ENGLISH TEXT electric contact, and hoistway-door and car-door or gate electric contact which has succesfully passed the tests specified in Part IX, Section 903, and which conforms to the applicable provisions of this code, shall be approved for use by the enforcing authority. Interlock switches which have not the engineering test requirements of Part IX, Section 903, and which have been approved by the enforcing authority, may be installed in connection with existing approved doorclosers and the combination door-closer and interlock switch approved as an interlock by the enforcing authority without additional tests, provided the combination door closer and interlock switch are installed and adjusted to conform to all the requirements of
Regl. 1277, art. 111.6b-111.6b: Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005 | Justis AI