Regl. 1277, art. 111.8a dup2
Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el Ãndice bajo Ley 149 de 12 dic, 2005
Cite as Reglamento Núm. 1277, Art. 111.8a dup2
Interlocks.
Hoistway doors shall be considered to be in the
closed position under the following conditions.
1. For horizontally sliding or swinging doors,
or vertically sliding counterweighted doors:
a. Only when the leading edge of the
door is within four (4) inches of the
nearest face of the jamb or when the
door panels of bi-parting type doors
are within four (4) inches of contact
with each other, provided that:
(1) The car is being operated
USAS, A17.1
from within the car only.
Ibid
(2) The doors are of the horizontally sliding type.
(3) The doors are power closed
or equipped with doors closers
(4) The hoistway-door interlock is
provided with means to lock
35
TEXTO EN ESPAÑOL
Excepción: Los artÃculos 4 y 5 son aplicables solamente cuando la leva de retroceso de un
dispositivo inmovilizador sea requerido
(Vea Regla 111.3c y la definición 3.31d)
Ibid