Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el Ãndice bajo Ley 149 de 12 dic, 2005
Cite as Reglamento Núm. 1277, Art. 111.8b
bination Mechanical Lock and Electric Contacts,
or with Hoistway-Door Electric Contacts.
Hoistway-doors provided with hoistway-door combination mechanical locks and electric contacts, and
hoistway doors provided with hoistway door electric
contacts, shall be considered to be in the closed
position under the following conditions:
1. For horizontally sliding or swinging doors,
when the clear open space between the leading edge of the door and the nearest face
of the door jamb does not exceed two (2)
inches.
2. For vertically counterweighted doors,
when the clear open space between the
- 38 -
ENGLISH TEXT
leading edge of the door and the landing
sill does not exceed two (2) inches.
3. For center-opening bi-parting horizontally
sliding doors or bi-parting vertically sliding counterbalanced doors, when the door
panels are within two (2) inches of contact
with each other.
4. For center-opening horizontally swinging
doors, when the clear open space between
each panel and its jamb does not exceed two
(2) inches; provided that if a hoistwaydoor electric contact is used on the door
panel which open last (See Section 111,