Parking devices shall conform to the following requirements: 1. They shall be machanically or electrically operated. 2. They shall be so designed and installed that friction or sticking or the breaking of any spring used in the device will not permit opening or unlocking a door when the car is outside the landing zone of that floor. 3. Springs, where used, shall be of the restrained compression type which will prevent separation of parts in case the spring breaks 45 I I TEXTO EN ESPAÑOL 3. El interruptor será del tipo de retroceso por el muelle de presión continua y será accionado por una cerradura de tipo cilíndrico que tenga no menos de cinco (5) clavijas O una combinación de cinco (5) discos con una llave removible solo cuando el interruptor este en su posición de desconectado. La cerradura no podrá ser operada por ninguna llave que opere cerraduras O dispositivos usados para otros fines en el edificio. La llave estará disponible y será usada solamente por el inspector, el encargado de la conservación del equipo y el hombre de servicio.