3. The car door or gate shall be equipped with a re-opening device conforming with the requirements of Rule 112.5. 4. A momentary-pressure type switch shall be provided in the car and at each landing, which, when operated, shall cause the car door or gate and the hoistway door at the landing to stop or to stop and re-open. 5. The average closing speed shall not exceed one (1) foot per second for a vertically sliding counterweighted hoistway door or for each panel of a bi-parting counterbalanced hoistway door or car gate, and shall not exceed two (2) feet per second for a vertically sliding-counterweighted car door or gate.