Regl. 1277, art. 206.4 dup2
Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el índice bajo Ley 149 de 12 dic, 2005
Cite as Reglamento Núm. 1277, Art. 206.4 dup2
Mechanism Switches.
206.4 - Where Required.
206.4a
A switch shall be provided on the speed governor
and operated by the over-speed action of the governor
when used with type B and C car safeties of elevators
having a rated speed exceeding one hundred fifty (150)
feet per minute. A switch shall be provided on the
speed governor when used a counterweight safety for
any car speed.
Every car safety shall be provided with a switch
operated by the car safety mechanism when the safety
is applied.
These switches shall, when operated, remove power
from the driving machine motor and brake before or at
the time of application of the safety.
206.4b - Setting of speed-governor overspeed switches.
206.4b
The setting of the car speed-governor overspeed
switch shall conform to the following:
1. For rated speeds more than one hundred fifty
(150) feet per minute, up to and including
TEXTO EN ESPAÑOL
69
La desviación o pandeo máximo permisible de las
piezas en las armazones y plataformas de los carros
basado en la carga estática a la cual serán sometidos
no será mayor de lo siguiente:
a. Cabezales 1/960 de la luz.
b. Tablonaje 1/960 de la luz.
C. Soportes (largueros), según lo determinado
en la Parte XII, Sección 1201, Regla 1201.5(c).
d. Para piezas del armazón de la plataforma,
1/960 de la luz.
NOTA: Los límites de las desviaciones señaladas en
esta regla son aplicables independientemente
USAS, A17.1
del tipo de acero u otro metal usado.