Regl. 1277, art. 207.7
Reglamento General de Seguridad e Higiene Industrial, Cap. IV -- Ascensores de personas. No incluido en el Ãndice bajo Ley 149 de 12 dic, 2005
Cite as Reglamento Núm. 1277, Art. 207.7
Rated Load.
Passenger and freight elevators may be used, where
necessary, to carry one-piece loads greater than their
rated load provided they are designed, installed and
operated to conform to the following requirements:
a. A locking device shall be provided which will
hold the car at any landing independently of
the hoisting ropes while the car is being loaded or unloaded.
b. The locking device shall be so designed that
it cannot be unlocked unless and until the
entire weight of the car and load is suspended
on the ropes.
c.A removable wrench or other device shall be
provided to operate the locking device.
d. The locking device shall be so designed that
USAS, A17.1
the locking bars will be automatically with-
Ibid
drawn should they come in contact with the