Regl. 7393, art. c-1-1 dup2

Reglamento para Endosos de Planos de Infraestructura y Servidumbres para Facilidades de Telecomunicaciones y Televisión por Cable

Length: 5,434 wordsOfficial source

Cite as Reglamento Núm. 7393, Art. c-1-1 dup2

4" 3" 1 CONDUIT CLAMP 1-1/2" 5 6 PVC 4" 1/2" 15'-0" MIN. POLE 14" 4" 1/2" RIGID 2" GALV. STEEL 4 CURVE 90'-36(R) P.V.C. CONDUITS 1-1/2" 2-4" & 2-2" DIA SIDE VIEW 1/2" 1/2" N.T.S. 210 @ 8"C.C 40"LONG JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO TOP VIEW DETAIL PVC GIP H.T.S. : ADAPTER 16 6 Concrete Base GROUND LEVEL = GND WIRE SOLID MIN. 3'.0" TO DEVELOPMENT a GROUND ROD 5/8" 4 #3 @ 6" CC 4" Ø & 2" Ø 90° 36"R 2-4" & 2-2" Ø PVC SCH 26 CONDUITS 10" LONG PVC BEND ENCASED IN CONCRETE TO 2 #3 @ CC 48" LONG JUNCTION BOX TELECOMUNICATIONS RISER DETAIL WOOD POLE 30-5 OR SIMILAR Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. SECCION D EJEMPLOS Y DETALLES TÉCNICOS DE INSTALACIÓN DE CAJAS DE EMPALMES Ejemplos Típicos Instalación "Planting" y Aceras JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO Detalles Típicos de Cajas de Empalmes y terminación de conductos LOT MP-2 LOT NP-2 DRIVEWAY LOT MP-1 JAZMIN ST. LOT NP-1 SIDEWALK PLANTING STRIP TELECOMMUNICATIONS SPLICING BOXES JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO NOTE: TELECOMMUNICATIONS BOX COVER WILL BE FLUSH MOUNTED WITH PLANTING STRIP FREE OF DAMAGE AND SECURE TO PEDESTRIAN. TELECOMMUNICATIONS BOX PLANTING STRIP INSTALLATION DETAIL - TYPICAL SCALE: NTS Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. LOT MP-2 LOT NP-2 DRIVEWAY LOT MP-1 JAZMIN ST. LOT NP-1 SIDEWALK PLANTING STRIP TELECOMMUNICATIONS SPLICING BOXES JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO NOTE: TELECOMMUNICATIONS BOXES COVER WILL BE FLUSH MOUNTED WITH SIDEWALK FREE OF DAMAGE AND SECURE TO PEDESTRIAN. TELECOMMUNICATIONS BOX SIDEWALK INSTALLATION DETAIL - TYPICAL SCALE: NTS Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. 4'-8" 4'-0" ELEVATION NO.4 4-01" ## 4-01" 4-01" 482 4-01" 4-02" 14 4 4-02" 001 4-02" 4-02" 4'-8" 3'-10 2 4'-8" 3'-10-2 ELEVATION NO.1 SUMP PIT ELEVATION NO.2 4-04" + 4-04" 4-04" + 4-04" 4'-8" 4'-0" + 10" 10" I HUECO PARA ELEVATION NO.1 HUECO PARK ELEVATION NO.2 VARILLA DE GROUND 4'-0" VARILLA DE GROUND 4'-0" N/A reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se ELEVATION NO.3 4'-8" 4'-8" TOP VIEW 4'-0" 4" 2 4-01" ***8 4-01" INSERT ELEVATION NO.4 2-02" 8 * 2-02" O 4 8" 4'-8" 3'-10₂ⁿ de 4'-8" 3'-10-2" ON ELEVATION NO.1 ELEVATION NO.2 2-04" + 2-04" 10" 1'-0" 4'-8" 4'-0" 43 ELEVATION NO.3 ELEVATION NO.4 HUECO PARA 4'-0" 4'-0" HUECO PARA VARILLA DE GROUND VARILLA DE GROUND 4'-8" SIDE VIEW 4'-8" ELEVATION NO.3 FRAME & COVER 36"x36" (COV-100 & FRA-100) PRECAST COVER 36"x36" TOP VIEW TOLA N" PRECAST COVER 36"x36" SECTION A-A ITEM NO. Telecommunications 4' X 4' X 4' PRODUCT ID. Equal or similar to Power Poles PBTC002 (PB-01) Utility Splicing Box PAGE: To be installed in secondary distribution areas only Typical Detail R JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 1" 001"0 00 00 4" 1" 1" 4" 2" 4" 8" 2" 10" 2" 4" 8" 10" oo 8" 14 HOLES RACK 1""IT 14" :: 8" 6" 1" JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO REVISIONS DATE INITIALS 00 :: NOTES: 00 1. NOT TO BE USED IN MAIN DISTRIBUTION ROUTES. 2. FOR SINGLE RESIDENTIAL LIVING UNITS DEVELOPMENTS ONLY. TELECOMMUNICATIONS DISTRIBUTION BOX INTERIOR 4' X 4' X 4' LAYOUT 3. TO SERVE A MAXIMUM OF 8 SINGLE LIVING UNITS. (TYPICAL) Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. 3-8 3'-0" 4 4-01 4-01" 5 5 2-02" 4-01" 5" 2-02" 4-01" ELEVATION NO.4 0000 10000 2-02" 0000 0000 100 too 2-02" 4 3'-0" 3'-0" + 3'-8" 3'-0" ELEVATION NO.1 ELEVATION NO.2 8-04" 8-04" is is + 4 4 ELEVATION NO.1 ELEVATION NO.2 3'-0" 3'-0" reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se 4 ELEVATION NO.3 3'-8" 3'-8" TOP VIEW 4-01" 4" 5" 3'-0" 4" 2-02 4-01" 0000 0000 3'-0' 100 2-02" 3'-0" ELEVATION NO.4 4 2-04 2-04" A A 4 3'-8" 3'-0" ELEVATION NO.1 ELEVATION NO.2 4 4 ELEVATION NO.3 ELEVATION NO.4 HUECO PARA VARILLA DE GROUND 3'-0" SIDE VIEW 3'-0" 3'-8" 3'-8" 4 ELEVATION NO.3 FRAME & COVER 36"x38" (COV-100 & FRA-100) PRECAST COVER 36"x36" PRECAST COVER 36"x36" TOP VIEW TOP VIEW TOLA A* PRECAST COVER 36"x36" SECTION A-A ITEM NO. Telecommunications 3' X 3' X 3' Equal or similar to Power Poles PBTC001 (PB-01) Distribution Splicing Box PRODUCT ID. To be installed in secondary distribution areas only Typical Detail PAGE: JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 1" 5" 1" 1" 2" 2" 4" 5" 2" 6" 2" 2" 6" 0000 14 HOLES RACK 12" 0000 . o 1" 5" JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 4" REVISIONS DATE INITIALS **** 0000 NOTES: 1. NOT TO BE USED IN MAIN DISTRIBUTION ROUTES. 2. FOR SINGLE RESIDENTIAL LIVING UNITS DEVELOPMENTS ONLY. TELECOMMUNICATIONS DISTRIBUTION BOX INTERIOR 3' X 3' X 3' LAYOUT 3. TO SERVE A MAXIMUM OF 8 SINGLE LIVING UNITS. (TYPICAL) Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. 7'-8" 6" 7'-0" 4-01" 4-01' does 4-01" 4-01" ELEVATION NO.4 8-02" 8-02 8-02" OOOO OOOO 0000 B-02' 4'-10" 3'-10-2" 3'-10-2" 12-04" 12-04" 5'-2" 4'-6" ELEVATION NO.1 + ELEVATION NO.2 100 SUMP PIT 10" 10" 4 ELEVATION NO.1 ELEVATION NO.2 (6)PULLING IRON 4'-6" 4'-6" reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se 5'-2" 5'-2" ELEVATION NO.3 SIDE VIEW TOP VIEW 7'-8" 12 8-01" 1'-0" INSERT **** INSERT 8-02' : 4'-10" 3'-10-2" 2'-0" 1'-4" 2'-2" 8-04 + $00 1'-6" A A 10" 10" 1'-0" 5'-2" 4 ELEVATION NO.3 ELEVATION NO.4 7'-0" 7'-0" 7'-8" 7'-8" STD. FRAME & COVER 42"x54" (COV-008 & FRA-008) PRECAST COVER TOP VIEW 7, APPROXIMATE WEIGHT: A) COVER: 1600 LBS. SIDE VIEW B) BOX: 6845 LBS. SECTION A-A TOTAL: 8445 LBS. ITEM NO. Telecommunications 7' X 4'-6" X 4' PRODUCT ID. Equal or similar to Power Poles PBTC003 (PB-00) Main Route Splicing Box PAGE: Designed for Side Walk Loading Typical Detail A JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 10" 8" 2" 1" 3" 1"->- 4" 4" ++ 2" 8" 8" 10" 2" 4" 6" 10" *4"+ 18" *6" 25 1/2" 2" PULLING IRON SUMP PIT 12" X 12" X 12 16 1/2" 84" 16 1/2" GROUND ROD 8'X 5/8" 25 1/2" 8" JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 1" 18 HOLES CABLE RACK REVISIONS DATE INITIALS NOTES: TO BE USED IN MAIN DISTRIBUTION ROUTES FOR: 1. SINGLE UNITS 2. WALK UPS 3. HIGH RISES COMMERCIAL TELECOMMUNICATIONS DISTRIBUTION & RESIDENCIAL 4. COMMERCIAL & BOX INTERIOR 7' X 4'-6" X 4' LAYOUT RESIDENTIAL DEV. (TYPICAL) Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. SECCION E EJEMPLOS Y DETALLES TÉCNICOS DE INSTALACIÓN DE "MANHOLES" Detalles Típicos de Cajas de Empalmes y JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO terminación de conductos Detalle Típico de "Frame / Cover" Notas Generales para "Manholes" de Telecomunicaciones 10 ELEVATION NO.4 10" 6 1'-0" 1'-0' 1'-0" 1'-0" DOD 000 1"-8" 3'-10- 1'-8" SUMP PIT 3'-10 6-02 5-02 6'-10" 6'-0" ELEVATION NO.1 ELEVATION NO.2 6-02 6-02" 7'-11" 7'-0" 4-04" 4-04" 4-04" 1-04" PULLING IRON (4) 3'-12- 1'-6" 3'-1½⁻ 1'-8" reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se 1"-2" 1'-2" 1'-0' 1'-0" ELEVATION NO.3 6'-0" ELEVATION NO.1 ELEVATION NO.2 6'-10" 6'-0" 5 6'-0" 6'-10" 6'-10" TOP VIEW 10 10' 6 + 1'-0" 11-0" + MANHOLE FRAME & COVER U.S. INSERT 000 ### FOUNDRY CAT. NO. USF-639 2'-5" 3'-102 6-02 3'-10) FINISH GRADING 6-02" + 8'-9' 1'-4 7'-0" 10" 4-04" 4-04" #3 REBAR 2'-3'he" @9" LONG VARIES 1'-8" 1'-0" 3'-1'2' 3'-12- 1'-2" 1'-0" 5" 3'-2" 5" ELEVATION NO.3 ELEVATION NO.4 MANHOLE COVER 6'-0" 6'-0" NOT TO SCALE 6'-10" SIDE VIEW 6'-10" ITEM NO Telecommunications 6' X 6' X 7' PRODUCT ID Equal or similar to Power Poles MH-TC001 (MH-00) Manhole PAGE For use in all areas exposed to vehicular traffic Typical Detail JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 1/8" 1" 1-1/4 7.30 2047-387 1" N/W 28-3/6* CAÇ CACIONES 1/8 27" 1-7/8" 3/1-1 IONES SEE DETAIL "&" reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se 10" VENT OPENINGS DIA. <<<<<<<<<<<<<<<<<<<<<<<<< JRTPR JR LETTERS DETAIL 36" (TYPICAL) 25/22" 62-12" FRAME SIDE VIEW ROUND - COVER TOP VIEW - 1,2/9 - 1/32" 7/5 DETAIL A I-1/I VENT OPENINGS DIA. DIA. FRAME TOP VIEW COVER BOTTON VIEW SECTION REVISIONS DATE INITIALS TELECOMMUNICATIONS MANHOLE FRAME & COVER DETAILS (TYPICAL) A JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO GENERAL NOTES FOR TELECOMMUNICATIONS MANHOLES 1. STRUCTURAL DESIGN MUST FOLLOW LOCAL CONSTRUCTION CODES AND REQUIREMENTS. 2. END BELLS (PVC SCH-40) TO BE POSITIONING AS INDICATED IN PROJECT PLANS. reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se 3. PULLING IRONS WILL BE LOCATED IN THE OPPOSITE SIDE OF END BELLS. 4. MANUFACTURER WILL PROVIDE THREE 3/4" Ø PVC CONDUIT FOR GROUNDING REQUIREMENTS. 5. SUMP PIT TO BE LOCATED AS SHOWN ON PRINTS. JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO SECCION F EJEMPLOS Y DIAGRAMAS TÍPICOS Ejemplos Típicos de Diagramas Monolneales Ejemplos Típicos de "Riser Diagrams" CATV Edificios Residenciales JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO o RICO Ejemplos Típicos de "Riser Diagrams" Teléfono Edificios Residenciales Ejemplos Típicos de "Riser Diagrams" CATV y Teléfono Walk-ups 4" X 4" X 2 1/8" (min) Junction Box for Service Wire Connection NOTES: 1. IN RESIDENTIAL LIVING UNITS, THE KITCHEN, LIVING ROOM AND EACH BEDROOM SHALL BE PROVIDED WITH MAIN OTHER TWO INDEPENDENT OUTLETS FOR TELEPHONE AND CATV LIVING ROOM KITCHEN BEDROOM BEDROOMS SERVICE. Tel. 2. THE INTERIOR RESIDENTIAL TELECOMMUNICATIONS 1T 2T 3T NT SERVICE CONDUITS SHALL HAVE A MINIMUM OF 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN THE DRAWINGS. 1" 0 PVC TO POINT OF reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detailes incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se 3. ALL INTERIOR OUTLETS SHALL BE 4" X 2" X 2 1/8", I" METALLIC WITH PLASTIC COVER AND "FISHWIRE". 3-4" 3-4" 3-4" CONNECTION 18" 8' X 5/8" GROUND ROD 1 #6 AWG THW SOLID, 3/4 Ø PVC SCH 40 LEGEND 4" X 4" X 2 1/8" (min) Junction Box for Service Wire Connection TELEPHONE OUTLET LIVING ROOM 1T MAIN OTHER LIVING ROOM KITCHEN BEDROOM BEDROOMS TELEPHONE OUTLET KITCHEN 1" Ø 2T To Point of CATV 1C 2C 3C NT Connection TELEPHONE OUTLET 1ST BEDROOM 3T TELEPHONE OUTLETS OTHER 1"0 3-4" 3-4"O 3-4"Ø 18" NT BEDROOMS 1C CATV OUTLET LIVING ROOM 8' X 5/8" GROUND ROD 2C CATV OUTLET KITCHEN 1 #6 AWG THW SOLID, 3/4 Ø PVC SCH 40 3C CATV OUTLET 1ST BEDROOM MONOLINEAL DIAGRAM NT CATV OUTLETS OTHER BEDROOMS INTERIOR TELEPHONE AND CATV DISTRIBUTION - SINGLE LIVING UNIT JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 36" X 24" x 6" TELEPHONE CABINET NOTES: 1. IN RESIDENTIAL LIVING UNITS, THE KITCHEN, LIVING ROOM AND EACH BEDROOM SHALL BE PROVIDED WITH MAIN OTHER LIVING ROOM TWO INDEPENDENT OUTLETS FOR TELEPHONE AND CATV KITCHEN BEDROOM BEDROOMS SERVICE. TTC 2. THE INTERIOR RESIDENTIAL TELECOMMUNICATIONS 1T 2T 3T NT SERVICE CONDUITS SHALL HAVE A MINIMUM OF 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN THE DRAWINGS. reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se 4" 0 PVC 3. OUTLET DIRECTLY CONNECTED TO TELECOMMUNICATIONS TO POINT OF 1" 3-4" 3-4" 3-4" CABINETS SHALL BE 4" X 4" X 2 1/8" (MIN), ALL OTHER CONNECTION 18" OUTLETS SHALL BE 4" X 2" X 2 1/8". 8' X 5/8" GROUND ROD 1 #6 AWG THW SOLID, 3/4 PVC SCH 40 LEGEND 36" X 24" X 6" CATV CABINET TELEPHONE OUTLET LIVING ROOM OTHER 1T MAIN BEDROOMS LIVING ROOM KITCHEN BEDROOM 2" 0 PVC (4"X2"X21/8") TELEPHONE OUTLET KITCHEN TO POINT OF 2T CONECTION CATV 1C 2C 3C NT TELEPHONE OUTLET 1ST BEDROOM 3T TELEPHONE OUTLETS OTHER 1"0 3-4" 3-4" V 3-4" 18" NT BEDROOMS 1C CATV OUTLET LIVING ROOM 8' X 5/8" GROUND ROD 1 #6 AWG THW SOLID, 3/4 Ø PVC SCH 40 2C CATV OUTLET KITCHEN 3C CATV OUTLET 1ST BEDROOM MONOLINEAL DIAGRAM NT CATV OUTLETS OTHER BEDROOMS INTERIOR TELEPHONE AND CATV DISTRIBUTION HIGH RISE & WALK-UPS SINGLE LIVING UNITS JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO Building Roof #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 CATV CATV CATV CATV CATV CATV DATV DATV CATV CATV APARTMENTS APARTMENTS Floor Level 5-1"0 5-10 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV APARTMENTS APARTMENTS Floor Level 5-1" 5-1 Ø #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 CATV CATV CATV CATV CATV 2-2" CATV CATV CATV CATV CATV APARTMENTS APARTMENTS Floor Level 5-1"0 5-1 Ø #1 #2 #3 #4 #5 #6 #7 #8 #8 #10 CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV APARTMENTS APARTMENTS Floor Level 5-1" 0 5-1 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 CATV CATV CATV CATV CATV 2-2" CATV CATV CATV CATV DATV APARTMENTS APARTMENTS Floor Level 2-1" 0 5-1" 0 5-1" 1-1" Ø GUARD MAIN CATV CABINET CATV CATV MCATV JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO ADMIN OFFICE CATV CATV CATV CATV COMMUNAL AREA GROUND LEVEL 1 #6 AWG THW SOLID LEGEND 24" 8'X5/8" GROUND ROD CATV 36" x 30" X 6" METAL TO TELECOMMUNICATIONS DISTRIBUTION BOX CABINET W/3/4" PLYWOOD BACKBOARD 2-2" 4" X 4" X 2-1/8" FLUSH NOTES: CATV MOUNTED WALL CATV 1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM OUTLET W/COVER PLATE SHALL BE PROVIDED WITH DUTLETS FOR CATV SERVICE. 4" X 2" X 2-1/8" FLUSH MOUNTED CATV WALL CATV OUTLET W/COVER 2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF PLATE 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN DRAWINGS. REVISIONS DATE INITIALS INTERIOR CATV 20 OR LESS APTS 3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS CABINETS SHALL BE 4" X 4" X 2-1/8" [MIN], ALL OTHER DISTRIBUTION RISER DIAGRAM OUTLETS SHALL BE 4" X 2" X 2-1/8". RESIDENTIAL BLDG. (TYPICAL) 4. THE MINIMUM SIZE FOR CATV CABINETS SHALL BE 36" X 30"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Building Roal APARTMENTS APARTMENTS #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV Floor Level 8-1" Ø 8-1 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV DATV Floor Level 8-1" 0 8-1 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV Floor Level 8-1" 8-1 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 CATV CATV DATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV Floor Level 8-1" 8-1 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 CATV CATV CATV CATV CATV CATV CATV CATV CATY CATV CAT CATV CATV CATV CATV CATV 2-2" Roor Level 4-1"0 8-1" 0 8-1" 0 3-1" 0 GUARD MAIN CATV CABINET CATV CATV MCATV JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO ADMIN OFFICE CATV CATV CATV DATV COMMUNAL AREA GROUND LEVEL 1 #6 AWG THW SOLID 24" 8' X 5/8" GROUND ROD LEGEND CATV 36" X 30" X 6" METAL TO TELECOMMUNICATIONS CABINET W/ 3/4" PLYWOOD DISTRIBUTION BOX BACKBOARD 2-2" 4" X 4" X2-1/8" FLUSH NOTES: CATV MOUNTED WALL CATV 1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM OUTLET W/COVER PLATE SHALL BE PROVIDED WITH OUTLETS FOR CATV SERVICE. 4" X 2" X 2-1/8" FLUSH MOUNTED ALT. 1 CATV WALL CATV OUTLET W/COVER 2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF PLATE 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN DRAWINGS. REVISIONS DATE INITIALS INTERIOR CATV-MORE THAN 20 3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS CABINETS SHALL BE 4" X 4" X 2-1/8" [MIN], ALL OTHER APTS DISTRIBUTION RISER DIAGRAM OUTLETS SHALL BE 4" X 2" X 2-1/8". RESIDENTIAL BLDG. (TYPICAL) 4. THE MINIMUM SIZE FOR CATV CABINETS SHALL BE 36" X 30"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Building Roof APARTMENTS APARTMENTS #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATY 8-1" 0 7-1" 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 CATV CATV CATV CATV CATY CATV CATV CATV CATV CATV CATV CATV DATY CATV CATV CATV CATV 7-1"0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 CATV CATV CATV CATY CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV 7-1"0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATY CATV CATV CATV 2-2" 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 CATV CATV CATV CATV CATY CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV CATV MAIN CATV CABINET 8-1"0 ADMIN OFFICE GUARD COMMUNAL AREA 5-1" CATV CATV CATY MCATV CATV DATV CATV 3-1" D GROUND LEVEL 1 #6 AWG THW SOLID JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 8' X 5/8" GROUND ROD 24" 2-2" D LEGEND CATV 36" X 30" X 6" METAL CABINET W/ 3/4" PLYWOOD BACKBOARD NOTES: 4" X 4" X 2-1/8" FLUSH CATV MOUNTED WALL CATV 1. THE KITCHEN. LIVING ROOM AND EACH BEDROOM OUTLET W/COVER PLATE SHALL BE PROVIDED WITH OUTLETS FOR CATV SERVICE 4" X 2" X 2-1/8" FLUSH MOUNTED 2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF ALT. 2 CATV WALL CATV OUTLET W/COVER PLATE 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN DRAWINGS. REVISIONS DATE INITIALS 3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS INTERIOR CATV MORE THAN 20 CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER APTS DISTRIBUTION RISER DIAGRAM OUTLETS SHALL BE 4" X 2" X 2-1/8". 4. THE MINIMUM SIZE FOR CATV CABINETS SHALL BE RESIDENTIAL BLDG. (TYPICAL) 36" X 30"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. ROOF PENTHOUSE SECOND LEVEL APT. APT.2 APT.3 APT.4 APT.5 APT.6 APT. APT.8 PENTHOUSE 2-1"0 2-1"0 2-1"0 2-1"0 FIRST LEVEL CATV CATV APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 2-1" 9TH. LEVEL 2-1"0 2-1"0 2-1"0 APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 2-1"D 2-1"0 BTH. LEVEL 2-1"0 2-1"0 2-2"0 2-2"0 APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 2-1"D 2-1"0 2-1"0 2-1"0 2ND. LEVEL CATV CATV APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 2-1"D 2-1"0 2-10 2-1"0 1ST LEVEL 2-2"0 2-2"0 SEE: ONE LINE DIAGRAM DETAIL CATV GABINET ADMINISTRATION 36° x 30° X 6* MIN. OFFICE GROUND LEVEL CATV GUARD COMUNAL 1-1"0 AREA 2-1"0 1#6 TO GROUNDING ELECTRODE SYSTEM 24" 2-20 2-2"0 ALT. 3 PROJECT TELECOMMUNICATION POINT OF CONNECTION REVISIONS DATE INITIALS INTERIOR RISER DIAGRAM HIGH RISE BUILDING CATV RESIDENTIAL (TYPICAL) Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Building Roof #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 APARTMENTS APARTMENTS Floor Level 5-1" 0 5-1 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 TTC APARTMENTS APARTMENTS Floor Level 5-1" 0 5-1 Ø #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 2-2" 01 APARTMENTS APARTMENTS Floor Level 5-1" 0 5-1 Ø #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 TTC APARTMENTS APARTMENTS Floor Level 5-1" 5-1 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 2-2" APARTMENTS APARTMENTS Floor Level 2-1" 0 5-1" 0 5-1" 0 1-1" 0 GUARD 8' X 3/4" WOOD PANEL BOARD MTTC JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO ADMIN OFFICE COMMUNAL AREA GROUND LEVEL 1 #6 AWG THW SOLID LEGEND 24" 8'X5/8" GROUND ROD 36" X 24" X 6" METAL TTC TO TELECOMMUNICATIONS CABINET W/3/4" PLYWOOD DISTRIBUTION BOX BACKBOARD 2-4"0 4" X 4" X 2-1/8" FLUSH NOTES: MOUNTED WALL TELEPHONE 1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM OUTLET W/COVER PLATE SHALL BE PROVIDED WITH OUTLETS FOR TELEPHONE 4" X 2" X 2-1/8" FLUSH MOUNTED SERVICE. WALL TELEPHONE OUTLET W/COVER 2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF PLATE 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN DRAWINGS. REVISIONS DATE INITIALS INTERIOR TEL. 20 OR LESS APTS 3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER DISTRIBUTION RISER DIAGRAM OUTLETS SHALL BE 4" X 2" X 2-1/8". RESIDENTIAL BLDG. (TYPICAL) 4. THE MINIMUM SIZE FOR TELEPHONE CABINETS SHALL BE 36" X 24" X 6" AND SHALL SERVE NO MORE THAN 20 UNITS. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Building Roof APARTMENTS APARTMENTS #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 8-1" 0 7-1". #8 #9 #10 #11 #12 #13 #14 #15 TTC #1 #2 #3 #4 #5 #6 #7 TTC 7-1" #8 #9 #10 #11 #12 #13 #14 #15 #1 #2 #3 #4 #5 #6 #7 7-1" 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 TTC TTC 2-2" 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 TTC WOOD PANNEL 8-1"0 ADMIN OFFICE GUARD COMMUNAL AREA 5-1" Ø MTTC 3-1" 0 GROUND LEVEL 1 #6 AWG THW SOLID 8'X 5/8" GROUND ROD 24" 2-2"0 JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO LEGEND TTC 36" X 24" X 6" METAL CABINET W/ 3/4" PLYWOOD BACKBOARD 4" X 4" X 2-1/8" FLUSH NOTES: MOUNTED WALL TELEPHONE 1. THE KITCHEN. LIVING ROOM AND EACH BEDROOM OUTLET W/COVER PLATE SHALL BE PROVIDED WITH OUTLETS FOR TELEPHONE SERVICE 4" X 2" X 2-1/8" FLUSH MOUNTED 2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF ALT. 1 WALL TELEPHONE OUTLET W/COVER PLATE 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN DRAWINGS. REVISIONS DATE INITIALS INTERIOR TEL. MORE THAN 20 3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER APTS DISTRIBUTION RISER DIAGRAM OUTLETS SHALL BE 4" X 2" X2-1/8". RESIDENTIAL BLDG. (TYPICAL) 4. THE MINIMUM SIZE FOR TELEPHONE CABINETS SHALL BE 36" X 24"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Buikling Roof #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 TTC Roor Level 8-1" 0 B-1 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 TTC Floor Level 8-1" 8-1 0 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 TTC Floor Level 8-1" 0 8-1 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 TTC Floor Level 8-1" 8-1 #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16 2-2"0 Floor Level 4-1" 0 8-1" 8-1"0 3-1" 0 GUARD 8' X X 3/4" WOOD PANEL BOARD MTTC ADMIN OFFICE COMMUNAL AREA JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO GROUND LEVEL 1 #6 AWG THW SOLID LEGEND 24" 8' X 5/8" GROUND ROD 36" X 24" X 6" METAL TO TELECOMMUNICATIONS TTC DISTRIBUTION BOX CABINET W/3/4" PLYWOOD BACKBOARD 2-4"0 NOTES: 4" X 4" X 2-1/8" FLUSH MOUNTED WALL TELEPHONE 1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM OUTLET W/COVER PLATE SHALL BE PROVIDED WITH OUTLETS FOR TELEPHONE SERVICE. 4" X 2" X 2-1/8" FLUSH MOUNTED 2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF ALT. 2 WALL TELEPHONE OUTLET W/COVER PLATE 3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN DRAWINGS. REVISIONS DATE INITIALS 3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS INTERIOR TEL. - MORE THAN 20 CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER APTS DISTRIBUTION RISER DIAGRAM OUTLETS SHALL BE 4" X 2" X2-1/8". 4. THE MINIMUM SIZE FOR TELEPHONE CABINETS SHALL BE RESIDENTIAL BLDG. (TYPICAL) 36" X 24" X 6" AND SHALL SERVE NO MORE THAN 20 UNITS. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. ROOF PENTHOUSE SECOND LEVEL APT. APT.2 APT.3 APT.4 APT.5 APT.8 APT.7 APT.8 2-1"0 2-1*0 2-1"0 PENTHOUSE 2-1"0 TTC TTC FIRST LEVEL APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 2-1"0 2-10 2-1*0 2-1"0 4TH. LEVEL APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 2-1"0 2-1"0 2-1"0 2-1" 3RD. LEVEL 2-2"0 2-2"0 APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 2-1"0 2-1"0 2-1"0 2.10 2ND. LEVEL TTC TTC APT.1 APT.2 APT.3 APT.4 APT.5 APT.6 APT.7 APT.8 2-1*0 2-10 2-1"0 2-1*0 1ST LEVEL 2-2"0 2-2"0 SEE: ONE LINE JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO DIAGRAM DETAIL PARKING ADMINISTRATION OFFICE M GROUND LEVEL 1-1"0 GUARD COMUNAL AREA 2-1"0 1#6 TO GROUNDING ELECTRODE SYSTEM 24" 2-4"0 2-2"0 PROJECT TELECOMMUNICATION ALT. 3 POINT OF CONNECTION TELEPHONE INTERIOR RISER DETAIL HIGH RISE BUILDING RESIDENTIAL Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Road APT. 1 APT.2 APT.3 APT.4 APT.1 APT.2 APT.3 APT.4 I1 Fifth Level 2-1"0 2-1"0 2-1"0 2-1"0 CATV TTC APT.1 APT.2 APT.3 APT.4 APT.1 APT.2 APT.3 APT.4 Fourth Level 2-1"0 2-1"0 2-1"0 2-1"0 APT.1 APT.2 APT.3 APT.4 APT.1 APT.2 APT.3 APT.4 $ 11 11 Third Level 2-1"0 2-1"0 2-1*0 2-1"0 2-2"0 2-2*0 APT.1 APT.2 APT.3 APT.4 APT.1 APT.2 APT.3 APT.4 1 X $ Second Level 2-1"0 2-1"0 2-1"0 2-1"0 CATV APT.2 TTC APT.1 APT.3 APT.4 APT.1 APT.2 APT.3 APT.4 If First Level 2-1"0 2-1*0 2-1"0 2-1"0 36" X 30" X 6' MIN CABINET SEE ONE LINE DIAGRAM SEE ONE LINE DIAGRAM 2-2"0 JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 24" 11#6 AWG THW SOLID 2-2"D E TELECOMMUNICATIONS 2-4"0 DISTRIBUTION BOX REVISIONS DATE INITIALS INTERIOR RISER DIAGRAM WALK-UPS (TYPICAL) CATV TELEPHONE Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. BLDG #3 BLDG #2 BLDG #1 TEL TEL TEL TEL TEL reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos-con con fines ilustrativos. La JRTPR se 2-4"0 TEL 4-4"0 2-2" 0 2-2" 0 2 4"0 2-4"0 SPLICING BOX BLDG #4 SPLICING BOX 7' X 4' 6" X 4' TO POINT OF CONECTION 7' X 4' 6" X 4" TEL 4-4"0 2-4"0 TEL TELEPHONE INFRAESTRUCTURE W-UPS DIAGRAM (TYPICAL) A JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO BLDG #2 BLDG #1 reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se CTC CTC CTC CTC 1-2" ø PVC 1-2" 0 PVC BLDG. # 3 CTC 1-2"0 1-2"0 -2-2" 0 1-2" 0 PVC 1-2"0 PVC 2-2' Ø PVC 2-2" 0-> 2-2" 0 PVC POINT OF CONNECTION CTC CATV INFRAESTRUCTURE W-UPS DIAGRAM (TYPICAL) A JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO SECCION G DETALLES TÍPICOS GABINETES Tabla de Requerimientos Detalles Típicos Paneles de Distribución Edificios Comerciales JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO Detalles Típicos Gabinetes en Metal TELECOMMUNICATIONS ROOMS WITH PLYWOOD PANELS 8' X 4' X 3/4" TELEPHONE PANELS CATV PANELS THIRD LEVEL CAPPED CAPPED FLOOR 2-4" 0 2-2" 0 SECOND LEVEL JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO CAPPED CAPPED FLOOR 2-4" 0 2-2" 0 MAIN TELEPHONE MAIN CATV PANEL PANEL FIRST LEVEL CAPPED CAPPED FLOOR 3 4" 0 PVC 2 2" Ø PVC TO TELECOMMUNICATION POINT OF CONNECTION TELECOMMUNICATIONS ROOMS INTERCONNECTION COMMERCIAL BUILDINGS (TYPICAL) Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. 6" 30"/24" PLYWOOD PANEL 3/4" 36" 1" Ø CONDUITS (MIN) 2 COND. 4" 0 PVC SCH 26 (MIN) CATV/TELEPHONE CABINET NTS 30"/24" 6" PLYWOOD PANEL 3/4" JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 36" 1" Ø CONDUITS (MIN) 2 COND. 2" Ø PVC SCH 26 (MIN) CATV/TELEPHONE CABINETS CABINETS WILL BE EQUIPPED WITH A S/4" PLYWOOD BACKBOARD, A HINGED DOOR WITH LATCH AND KEY AND SHALL HAVE COMPLETE FRONTAL ACCESS. THE CABINETS SHALL ALSO PROVIDE FOR THE PROPER BONDING AND GROUNDING OF THE TELECOMMUNICATIONS FACILITIES. REVISIONS DATE INITIALS METAL CABINETS WALL MOUNTED CONDUITS TERMINATIONS Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. o RAINTIGHT 30"/24" 6" COVER o o reserva el derecho de enmendar los mismos conforme las necesidades del servicio. Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se HANDLE HANDLE 36" PADLOCK HINGED DOOR PADLOCK SIDE VIEW ISOMETRIC VIEW AS REQUIRED FRONT VIEW SPECIFICATIONS: 1. CABINET MUST COMPLY WITH NEMA SPECIFICATIONS. 2. MATERIAL CLEANED AND DEGREASED PRIOR TO PAINT. 3. FINISH: ANSI #61 DRY. 155E115-U GRAY POLYESTER POWDER COATING. 4. FLUSH WITH PLYWOOD BACKBOARD 3/4" THICK 5. MATERIAL TO #12 GALVANIZE STEEL 304 6. MINIMUN STANDARDS TO NEMA TYPE 2 DESIGNATION SPECIFICATIONS. REVISIONS DATE INITIALS METAL CABINET WALL MOUNTED SPECIFICATIONS JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO EXTERIOR WALL METALLIC INTERIOR METALLIC BOXES 4" X 4" X 2-1/8" BOXES 4" X 2" X 2-1/8" INTERIOR METALLIC 3/4" 0 3/4" 0 BOXES 4" X 2" X 2-1/8" 3/4"0 CONDUIT FOR COMMON GROUND 3/4" 0 1" Ø CONDUIT TO TELEPHONE DISTRIBUTION BOX 1" Ø CONDUIT TO CATV DISTRIBUTION POINT IN PLANTING STRIP OUTER WALL TYPICAL EXTERIOR METALLIC BOX 4" X 4" X 2-1/8" RIGHT OF WAY 24" TO 30" INSIDE FINISHED FLOOR 16" 6" TELEPHONE 2-1"0 PVC. 14" DISTRIBUTION 3/4" 0 FOR BOX GND WIRE TO CATV DISTRIBUTION POINT IN PLANTING STRIP NOTE: JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO 60" TWO 4" X 2" X 2-1/8" METALLIC BOXES FOR TELEPHONE AND CATV SERVICE WILL BE INSTALLED IN EACH BEDROOM, KITCHEN AND LIVING ROOM, CONNECTED TO THE CORRESPONDING SYSTEM WITH A 3/4" Ø CONDUITS. TELECOMMUNICATIONS METALLIC BOXES & INDIVIDUAL CONDUITS DETAIL Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se reserva el derecho de enmendar los mismos conforme las necesidades del servicio. SECCION H FORMULARIOS Forma JRTPR F-101 Solicitud de Servicios para Endoso Forma JRTPR F-102 Solicitud de Endoso de JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO Obras Construidas Forma JRTPR F-103 Solicitud de Asignación de Infraestructura Forma JRTPR F-104 Solicitud de Endoso A Proyectos de Relocalizacion de Infraestructura SECCION I MODELOS DE ESCRITURA Escritura Modelo Proyecto Comercial JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO Escritura Modelo Proyecto Urbanizació y Walk-ups
Regl. 7393, art. c-1-1 dup2: Reglamento para Endosos de Planos de Infraestructura y Servidumbres para Facilidades de Telecomunicaciones y Televisión por Cable | Justis AI