Regl. 7393, art. c-1-1 dup2
Reglamento para Endosos de Planos de Infraestructura y Servidumbres para Facilidades de Telecomunicaciones y Televisión por Cable
Length: 5,434 wordsOfficial source
Cite as Reglamento Núm. 7393, Art. c-1-1 dup2
4"
3"
1
CONDUIT
CLAMP
1-1/2"
5 6 PVC
4"
1/2"
15'-0"
MIN.
POLE
14"
4"
1/2"
RIGID
2"
GALV. STEEL
4 CURVE 90'-36(R) P.V.C.
CONDUITS
1-1/2"
2-4" & 2-2" DIA
SIDE VIEW
1/2"
1/2"
N.T.S.
210 @ 8"C.C
40"LONG
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
TOP VIEW DETAIL
PVC GIP
H.T.S.
:
ADAPTER
16
6
Concrete Base
GROUND LEVEL
=
GND WIRE SOLID
MIN.
3'.0"
TO DEVELOPMENT
a
GROUND ROD 5/8"
4 #3 @ 6" CC
4" Ø & 2" Ø 90° 36"R
2-4" & 2-2" Ø PVC SCH 26 CONDUITS
10" LONG
PVC BEND
ENCASED IN CONCRETE TO
2 #3 @ CC
48" LONG
JUNCTION BOX
TELECOMUNICATIONS RISER DETAIL
WOOD POLE 30-5 OR SIMILAR
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
SECCION D
EJEMPLOS Y DETALLES TÉCNICOS DE
INSTALACIÓN DE CAJAS DE EMPALMES
Ejemplos Típicos Instalación "Planting" y
Aceras
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
Detalles Típicos de Cajas de Empalmes y
terminación de conductos
LOT MP-2
LOT NP-2
DRIVEWAY
LOT MP-1
JAZMIN ST.
LOT NP-1
SIDEWALK
PLANTING STRIP
TELECOMMUNICATIONS
SPLICING BOXES
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
NOTE: TELECOMMUNICATIONS BOX COVER WILL BE
FLUSH MOUNTED WITH PLANTING STRIP FREE OF
DAMAGE AND SECURE TO PEDESTRIAN.
TELECOMMUNICATIONS BOX PLANTING
STRIP INSTALLATION DETAIL - TYPICAL
SCALE: NTS
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
LOT MP-2
LOT NP-2
DRIVEWAY
LOT MP-1
JAZMIN ST.
LOT NP-1
SIDEWALK
PLANTING STRIP
TELECOMMUNICATIONS
SPLICING BOXES
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
NOTE: TELECOMMUNICATIONS BOXES COVER WILL BE
FLUSH MOUNTED WITH SIDEWALK FREE OF DAMAGE AND
SECURE TO PEDESTRIAN.
TELECOMMUNICATIONS BOX SIDEWALK
INSTALLATION DETAIL - TYPICAL
SCALE: NTS
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
4'-8"
4'-0"
ELEVATION NO.4
4-01"
##
4-01"
4-01"
482
4-01"
4-02"
14
4
4-02"
001
4-02"
4-02"
4'-8" 3'-10 2
4'-8" 3'-10-2
ELEVATION NO.1
SUMP PIT
ELEVATION NO.2
4-04"
+
4-04"
4-04"
+
4-04"
4'-8" 4'-0"
+
10"
10"
I
HUECO PARA
ELEVATION NO.1
HUECO PARK
ELEVATION NO.2
VARILLA DE GROUND
4'-0"
VARILLA DE GROUND
4'-0"
N/A
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
ELEVATION NO.3
4'-8"
4'-8"
TOP VIEW
4'-0"
4"
2
4-01"
***8
4-01"
INSERT
ELEVATION NO.4
2-02"
8
*
2-02"
O
4
8"
4'-8" 3'-10₂ⁿ
de
4'-8" 3'-10-2"
ON ELEVATION NO.1
ELEVATION NO.2
2-04"
+
2-04"
10"
1'-0"
4'-8" 4'-0"
43
ELEVATION NO.3
ELEVATION NO.4
HUECO PARA
4'-0"
4'-0"
HUECO PARA
VARILLA DE GROUND
VARILLA DE GROUND
4'-8"
SIDE VIEW
4'-8"
ELEVATION NO.3
FRAME & COVER 36"x36"
(COV-100 & FRA-100)
PRECAST COVER 36"x36"
TOP VIEW
TOLA N"
PRECAST COVER 36"x36"
SECTION A-A
ITEM NO.
Telecommunications 4' X 4' X 4'
PRODUCT ID.
Equal or similar to Power Poles PBTC002 (PB-01)
Utility Splicing Box
PAGE:
To be installed in secondary distribution areas only
Typical Detail
R
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
1"
001"0
00
00
4"
1"
1"
4"
2"
4"
8"
2"
10"
2"
4"
8"
10"
oo
8"
14 HOLES RACK
1""IT
14"
::
8"
6"
1"
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
REVISIONS
DATE
INITIALS
00
::
NOTES:
00
1. NOT TO BE USED IN MAIN
DISTRIBUTION ROUTES.
2. FOR SINGLE RESIDENTIAL
LIVING UNITS
DEVELOPMENTS ONLY.
TELECOMMUNICATIONS DISTRIBUTION
BOX INTERIOR 4' X 4' X 4' LAYOUT
3. TO SERVE A MAXIMUM OF 8
SINGLE LIVING UNITS.
(TYPICAL)
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
3-8
3'-0"
4
4-01
4-01"
5
5
2-02"
4-01"
5"
2-02"
4-01"
ELEVATION NO.4
0000
10000
2-02"
0000
0000
100
too
2-02"
4
3'-0"
3'-0"
+
3'-8" 3'-0"
ELEVATION NO.1
ELEVATION NO.2
8-04"
8-04"
is
is
+
4
4
ELEVATION NO.1
ELEVATION NO.2
3'-0"
3'-0"
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
4
ELEVATION NO.3
3'-8"
3'-8"
TOP VIEW
4-01"
4"
5"
3'-0"
4"
2-02
4-01"
0000
0000
3'-0'
100
2-02"
3'-0"
ELEVATION NO.4
4
2-04
2-04"
A
A
4
3'-8" 3'-0"
ELEVATION NO.1
ELEVATION NO.2
4
4
ELEVATION NO.3
ELEVATION NO.4
HUECO PARA
VARILLA DE GROUND
3'-0"
SIDE VIEW
3'-0"
3'-8"
3'-8"
4
ELEVATION NO.3
FRAME & COVER 36"x38"
(COV-100 & FRA-100)
PRECAST COVER 36"x36"
PRECAST COVER 36"x36"
TOP VIEW
TOP VIEW
TOLA A*
PRECAST COVER 36"x36"
SECTION A-A
ITEM NO.
Telecommunications 3' X 3' X 3'
Equal or similar to Power Poles PBTC001 (PB-01)
Distribution Splicing Box
PRODUCT ID.
To be installed in secondary distribution areas only
Typical Detail
PAGE:
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
1"
5"
1"
1"
2"
2"
4"
5"
2"
6"
2"
2"
6"
0000
14 HOLES RACK
12"
0000
.
o
1"
5"
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
4"
REVISIONS
DATE
INITIALS
****
0000
NOTES:
1. NOT TO BE USED IN MAIN
DISTRIBUTION ROUTES.
2. FOR SINGLE RESIDENTIAL
LIVING UNITS
DEVELOPMENTS ONLY.
TELECOMMUNICATIONS DISTRIBUTION
BOX INTERIOR 3' X 3' X 3' LAYOUT
3. TO SERVE A MAXIMUM OF 8
SINGLE LIVING UNITS.
(TYPICAL)
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
7'-8"
6"
7'-0"
4-01"
4-01'
does
4-01"
4-01"
ELEVATION NO.4
8-02"
8-02
8-02"
OOOO
OOOO
0000
B-02'
4'-10" 3'-10-2"
3'-10-2"
12-04"
12-04"
5'-2" 4'-6"
ELEVATION NO.1
+
ELEVATION NO.2
100
SUMP PIT
10"
10"
4
ELEVATION NO.1
ELEVATION NO.2
(6)PULLING IRON
4'-6"
4'-6"
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
5'-2"
5'-2"
ELEVATION NO.3
SIDE VIEW
TOP VIEW
7'-8"
12
8-01"
1'-0"
INSERT
****
INSERT
8-02'
:
4'-10"
3'-10-2"
2'-0"
1'-4"
2'-2"
8-04
+
$00
1'-6"
A
A
10"
10"
1'-0"
5'-2"
4
ELEVATION NO.3
ELEVATION NO.4
7'-0"
7'-0"
7'-8"
7'-8"
STD. FRAME & COVER 42"x54"
(COV-008 & FRA-008)
PRECAST COVER
TOP VIEW
7,
APPROXIMATE WEIGHT:
A) COVER: 1600 LBS.
SIDE VIEW
B) BOX: 6845 LBS.
SECTION A-A
TOTAL: 8445 LBS.
ITEM NO.
Telecommunications 7' X 4'-6" X 4'
PRODUCT ID.
Equal or similar to Power Poles PBTC003 (PB-00)
Main Route Splicing Box
PAGE:
Designed for Side Walk Loading
Typical Detail
A
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
10"
8"
2"
1"
3"
1"->-
4"
4"
++
2"
8"
8"
10"
2"
4"
6"
10"
*4"+
18"
*6"
25 1/2"
2"
PULLING IRON
SUMP PIT
12" X 12" X 12
16 1/2"
84"
16 1/2"
GROUND ROD 8'X 5/8"
25 1/2"
8"
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
1"
18 HOLES CABLE RACK
REVISIONS
DATE
INITIALS
NOTES:
TO BE USED IN MAIN
DISTRIBUTION ROUTES FOR:
1. SINGLE UNITS
2. WALK UPS
3. HIGH RISES COMMERCIAL
TELECOMMUNICATIONS DISTRIBUTION
& RESIDENCIAL
4. COMMERCIAL &
BOX INTERIOR 7' X 4'-6" X 4' LAYOUT
RESIDENTIAL DEV.
(TYPICAL)
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
SECCION E
EJEMPLOS Y DETALLES TÉCNICOS DE
INSTALACIÓN DE "MANHOLES"
Detalles Típicos de Cajas de Empalmes y
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
terminación de conductos
Detalle Típico de "Frame / Cover"
Notas Generales para "Manholes" de
Telecomunicaciones
10
ELEVATION NO.4
10"
6
1'-0"
1'-0'
1'-0"
1'-0"
DOD
000
1"-8"
3'-10-
1'-8"
SUMP PIT
3'-10
6-02
5-02
6'-10" 6'-0"
ELEVATION NO.1
ELEVATION NO.2
6-02
6-02"
7'-11"
7'-0"
4-04"
4-04"
4-04"
1-04"
PULLING IRON (4)
3'-12-
1'-6"
3'-1½⁻
1'-8"
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
1"-2"
1'-2"
1'-0'
1'-0"
ELEVATION NO.3
6'-0"
ELEVATION NO.1
ELEVATION NO.2
6'-10"
6'-0"
5
6'-0"
6'-10"
6'-10"
TOP VIEW
10
10'
6
+
1'-0"
11-0"
+
MANHOLE FRAME & COVER U.S.
INSERT
000
###
FOUNDRY CAT. NO. USF-639
2'-5"
3'-102
6-02
3'-10)
FINISH GRADING
6-02"
+
8'-9'
1'-4
7'-0"
10"
4-04"
4-04"
#3 REBAR
2'-3'he"
@9" LONG
VARIES
1'-8"
1'-0"
3'-1'2'
3'-12-
1'-2"
1'-0"
5"
3'-2"
5"
ELEVATION NO.3
ELEVATION NO.4
MANHOLE COVER
6'-0"
6'-0"
NOT TO SCALE
6'-10"
SIDE VIEW
6'-10"
ITEM NO
Telecommunications 6' X 6' X 7'
PRODUCT ID
Equal or similar to Power Poles MH-TC001 (MH-00)
Manhole
PAGE
For use in all areas exposed to vehicular traffic
Typical Detail
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
1/8"
1"
1-1/4
7.30
2047-387
1"
N/W
28-3/6*
CAÇ
CACIONES
1/8
27"
1-7/8"
3/1-1
IONES
SEE DETAIL "&"
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
10"
VENT OPENINGS
DIA.
<<<<<<<<<<<<<<<<<<<<<<<<<
JRTPR
JR
LETTERS DETAIL
36"
(TYPICAL)
25/22"
62-12"
FRAME SIDE VIEW
ROUND -
COVER TOP VIEW
-
1,2/9
-
1/32"
7/5
DETAIL A
I-1/I
VENT OPENINGS
DIA.
DIA.
FRAME TOP VIEW
COVER BOTTON VIEW
SECTION
REVISIONS
DATE
INITIALS
TELECOMMUNICATIONS MANHOLE
FRAME & COVER DETAILS
(TYPICAL)
A
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
GENERAL NOTES FOR TELECOMMUNICATIONS MANHOLES
1. STRUCTURAL DESIGN MUST FOLLOW LOCAL CONSTRUCTION
CODES AND REQUIREMENTS.
2. END BELLS (PVC SCH-40) TO BE POSITIONING AS INDICATED IN
PROJECT PLANS.
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
3. PULLING IRONS WILL BE LOCATED IN THE OPPOSITE SIDE OF
END BELLS.
4. MANUFACTURER WILL PROVIDE THREE 3/4" Ø PVC CONDUIT FOR
GROUNDING REQUIREMENTS.
5. SUMP PIT TO BE LOCATED AS SHOWN ON PRINTS.
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
SECCION F
EJEMPLOS Y DIAGRAMAS TÍPICOS
Ejemplos Típicos de Diagramas Monolneales
Ejemplos Típicos de "Riser Diagrams" CATV
Edificios Residenciales
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO o RICO
Ejemplos Típicos de "Riser Diagrams" Teléfono
Edificios Residenciales
Ejemplos Típicos de "Riser Diagrams" CATV y
Teléfono Walk-ups
4" X 4" X 2 1/8" (min) Junction
Box for Service Wire Connection
NOTES:
1. IN RESIDENTIAL LIVING UNITS, THE KITCHEN, LIVING ROOM
AND EACH BEDROOM SHALL BE PROVIDED WITH
MAIN
OTHER
TWO INDEPENDENT OUTLETS FOR TELEPHONE AND CATV
LIVING ROOM
KITCHEN
BEDROOM
BEDROOMS
SERVICE.
Tel.
2. THE INTERIOR RESIDENTIAL TELECOMMUNICATIONS
1T
2T
3T
NT
SERVICE CONDUITS SHALL HAVE A MINIMUM OF 3/4" UNLESS
ANOTHER DIAMETER IS SPECIFIED IN THE DRAWINGS.
1" 0 PVC
TO POINT OF
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detailes incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
3. ALL INTERIOR OUTLETS SHALL BE 4" X 2" X 2 1/8",
I"
METALLIC WITH PLASTIC COVER AND "FISHWIRE".
3-4"
3-4"
3-4"
CONNECTION
18"
8' X 5/8" GROUND ROD
1 #6 AWG THW SOLID, 3/4
Ø
PVC
SCH
40
LEGEND
4" X 4" X 2 1/8" (min) Junction
Box for Service Wire Connection
TELEPHONE OUTLET LIVING ROOM
1T
MAIN
OTHER
LIVING ROOM
KITCHEN
BEDROOM
BEDROOMS
TELEPHONE OUTLET KITCHEN
1" Ø
2T
To Point of
CATV
1C
2C
3C
NT
Connection
TELEPHONE OUTLET 1ST BEDROOM
3T
TELEPHONE OUTLETS OTHER
1"0
3-4"
3-4"O
3-4"Ø
18"
NT
BEDROOMS
1C
CATV OUTLET LIVING ROOM
8' X 5/8" GROUND ROD
2C
CATV OUTLET KITCHEN
1 #6 AWG THW SOLID, 3/4
Ø
PVC SCH 40
3C
CATV OUTLET 1ST BEDROOM
MONOLINEAL DIAGRAM
NT
CATV OUTLETS OTHER BEDROOMS
INTERIOR TELEPHONE AND CATV
DISTRIBUTION - SINGLE LIVING UNIT
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
36" X 24" x 6"
TELEPHONE CABINET
NOTES:
1. IN RESIDENTIAL LIVING UNITS, THE KITCHEN, LIVING ROOM
AND EACH BEDROOM SHALL BE PROVIDED WITH
MAIN
OTHER
LIVING ROOM
TWO INDEPENDENT OUTLETS FOR TELEPHONE AND CATV
KITCHEN
BEDROOM
BEDROOMS
SERVICE.
TTC
2. THE INTERIOR RESIDENTIAL TELECOMMUNICATIONS
1T
2T
3T
NT
SERVICE CONDUITS SHALL HAVE A MINIMUM OF 3/4" UNLESS
ANOTHER DIAMETER IS SPECIFIED IN THE DRAWINGS.
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
4" 0 PVC
3. OUTLET DIRECTLY CONNECTED TO TELECOMMUNICATIONS
TO POINT OF
1"
3-4"
3-4"
3-4"
CABINETS SHALL BE 4" X 4" X 2 1/8" (MIN), ALL OTHER
CONNECTION
18"
OUTLETS SHALL BE 4" X 2" X 2 1/8".
8' X 5/8" GROUND ROD
1 #6 AWG THW SOLID, 3/4
PVC SCH 40
LEGEND
36" X 24" X 6"
CATV CABINET
TELEPHONE OUTLET LIVING ROOM
OTHER
1T
MAIN
BEDROOMS
LIVING ROOM
KITCHEN
BEDROOM
2" 0 PVC
(4"X2"X21/8")
TELEPHONE OUTLET KITCHEN
TO POINT OF
2T
CONECTION
CATV
1C
2C
3C
NT
TELEPHONE OUTLET 1ST BEDROOM
3T
TELEPHONE OUTLETS OTHER
1"0
3-4"
3-4" V
3-4"
18"
NT
BEDROOMS
1C
CATV OUTLET LIVING ROOM
8' X 5/8" GROUND ROD
1 #6 AWG THW SOLID, 3/4 Ø PVC SCH 40
2C
CATV OUTLET KITCHEN
3C
CATV OUTLET 1ST BEDROOM
MONOLINEAL DIAGRAM
NT
CATV OUTLETS OTHER BEDROOMS
INTERIOR TELEPHONE AND CATV DISTRIBUTION
HIGH RISE & WALK-UPS SINGLE LIVING UNITS
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
Building Roof
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
CATV
CATV
CATV
CATV
CATV
CATV
DATV
DATV
CATV
CATV
APARTMENTS
APARTMENTS
Floor Level
5-1"0
5-10
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
APARTMENTS
APARTMENTS
Floor Level
5-1"
5-1 Ø
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
CATV
CATV
CATV
CATV
CATV
2-2"
CATV
CATV
CATV
CATV
CATV
APARTMENTS
APARTMENTS
Floor Level
5-1"0
5-1 Ø
#1
#2
#3
#4
#5
#6
#7
#8
#8
#10
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
APARTMENTS
APARTMENTS
Floor Level
5-1" 0
5-1
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
CATV
CATV
CATV
CATV
CATV
2-2"
CATV
CATV
CATV
CATV
DATV
APARTMENTS
APARTMENTS
Floor Level
2-1" 0
5-1" 0
5-1"
1-1" Ø
GUARD
MAIN CATV CABINET
CATV
CATV
MCATV
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
ADMIN OFFICE
CATV
CATV
CATV
CATV
COMMUNAL AREA
GROUND LEVEL
1 #6 AWG THW SOLID
LEGEND
24"
8'X5/8" GROUND ROD
CATV
36" x 30" X 6" METAL
TO TELECOMMUNICATIONS
DISTRIBUTION BOX
CABINET W/3/4" PLYWOOD
BACKBOARD
2-2"
4" X 4" X 2-1/8" FLUSH
NOTES:
CATV
MOUNTED WALL CATV
1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM
OUTLET W/COVER PLATE
SHALL BE PROVIDED WITH DUTLETS FOR CATV
SERVICE.
4" X 2" X 2-1/8" FLUSH MOUNTED
CATV
WALL CATV OUTLET W/COVER
2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF
PLATE
3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN
DRAWINGS.
REVISIONS
DATE
INITIALS
INTERIOR CATV 20 OR LESS APTS
3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS
CABINETS SHALL BE 4" X 4" X 2-1/8" [MIN], ALL OTHER
DISTRIBUTION RISER DIAGRAM
OUTLETS SHALL BE 4" X 2" X 2-1/8".
RESIDENTIAL BLDG. (TYPICAL)
4. THE MINIMUM SIZE FOR CATV CABINETS SHALL BE
36" X 30"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Building Roal
APARTMENTS
APARTMENTS
#1
#2
#3
#4
#5
#6
#7
#8
#9 #10 #11 #12 #13 #14 #15 #16
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
Floor Level
8-1" Ø
8-1 0
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
#16
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
DATV
Floor Level
8-1" 0
8-1
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
#16
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
Floor Level
8-1"
8-1 0
#1
#2
#3
#4
#5
#6
#7
#8
#9 #10 #11 #12 #13 #14 #15 #16
CATV
CATV
DATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
Floor Level
8-1"
8-1 0
#1
#2
#3
#4
#5
#6
#7
#8
#9 #10 #11 #12 #13 #14 #15 #16
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATY
CATV
CAT
CATV
CATV
CATV
CATV
CATV
2-2"
Roor Level
4-1"0
8-1" 0
8-1" 0
3-1" 0
GUARD
MAIN CATV CABINET
CATV
CATV
MCATV
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
ADMIN OFFICE
CATV
CATV
CATV
DATV
COMMUNAL AREA
GROUND LEVEL
1 #6 AWG THW SOLID
24"
8' X 5/8" GROUND ROD
LEGEND
CATV
36" X 30" X 6" METAL
TO TELECOMMUNICATIONS
CABINET W/ 3/4" PLYWOOD
DISTRIBUTION BOX
BACKBOARD
2-2"
4" X 4" X2-1/8" FLUSH
NOTES:
CATV
MOUNTED WALL CATV
1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM
OUTLET W/COVER PLATE
SHALL BE PROVIDED WITH OUTLETS FOR CATV
SERVICE.
4" X 2" X 2-1/8" FLUSH MOUNTED
ALT. 1
CATV
WALL CATV OUTLET W/COVER
2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF
PLATE
3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN
DRAWINGS.
REVISIONS
DATE
INITIALS
INTERIOR CATV-MORE THAN 20
3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS
CABINETS SHALL BE 4" X 4" X 2-1/8" [MIN], ALL OTHER
APTS DISTRIBUTION RISER DIAGRAM
OUTLETS SHALL BE 4" X 2" X 2-1/8".
RESIDENTIAL BLDG. (TYPICAL)
4. THE MINIMUM SIZE FOR CATV CABINETS SHALL BE
36" X 30"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Building Roof
APARTMENTS
APARTMENTS
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATY
8-1" 0
7-1" 0
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
CATV
CATV
CATV
CATV
CATY
CATV
CATV
CATV
CATV
CATV
CATV
CATV
DATY
CATV
CATV
CATV
CATV
7-1"0
#1
#2
#3
#4
#5
#6
#7
#8 #9 #10 #11 #12 #13 #14 #15
CATV
CATV
CATV
CATY
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
7-1"0
#1
#2
#3
#4
#5
#6
#7
#8 #9 #10 #11 #12 #13 #14 #15
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATY
CATV
CATV
CATV
2-2" 0
#1
#2
#3
#4
#5
#6
#7
#8
#9 #10 #11 #12 #13 #14 #15 #16
CATV
CATV
CATV
CATV
CATY
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
CATV
MAIN CATV CABINET
8-1"0
ADMIN OFFICE
GUARD
COMMUNAL AREA
5-1"
CATV
CATV
CATY
MCATV
CATV
DATV
CATV
3-1" D
GROUND LEVEL
1 #6 AWG THW SOLID
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
8' X 5/8" GROUND ROD
24"
2-2" D
LEGEND
CATV
36" X 30" X 6" METAL
CABINET W/ 3/4" PLYWOOD
BACKBOARD
NOTES:
4" X 4" X 2-1/8" FLUSH
CATV
MOUNTED WALL CATV
1. THE KITCHEN. LIVING ROOM AND EACH BEDROOM
OUTLET W/COVER PLATE
SHALL BE PROVIDED WITH OUTLETS FOR CATV
SERVICE
4" X 2" X 2-1/8" FLUSH MOUNTED
2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF
ALT. 2
CATV
WALL CATV OUTLET W/COVER
PLATE
3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN
DRAWINGS.
REVISIONS
DATE
INITIALS
3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS
INTERIOR CATV MORE THAN 20
CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER
APTS DISTRIBUTION RISER DIAGRAM
OUTLETS SHALL BE 4" X 2" X 2-1/8".
4. THE MINIMUM SIZE FOR CATV CABINETS SHALL BE
RESIDENTIAL BLDG. (TYPICAL)
36" X 30"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
ROOF
PENTHOUSE
SECOND LEVEL
APT.
APT.2
APT.3
APT.4
APT.5
APT.6
APT.
APT.8
PENTHOUSE
2-1"0
2-1"0
2-1"0
2-1"0
FIRST LEVEL
CATV
CATV
APT.1 APT.2
APT.3
APT.4
APT.5
APT.6
APT.7
APT.8
2-1"
9TH. LEVEL
2-1"0
2-1"0
2-1"0
APT.1 APT.2
APT.3
APT.4
APT.5
APT.6
APT.7
APT.8
2-1"D
2-1"0
BTH. LEVEL
2-1"0
2-1"0
2-2"0
2-2"0
APT.1 APT.2
APT.3
APT.4
APT.5
APT.6
APT.7
APT.8
2-1"D
2-1"0
2-1"0
2-1"0
2ND. LEVEL
CATV
CATV
APT.1
APT.2
APT.3
APT.4
APT.5
APT.6
APT.7
APT.8
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
2-1"D
2-1"0
2-10
2-1"0
1ST LEVEL
2-2"0
2-2"0
SEE: ONE LINE
DIAGRAM DETAIL
CATV GABINET
ADMINISTRATION
36° x 30° X 6* MIN.
OFFICE
GROUND LEVEL
CATV
GUARD COMUNAL
1-1"0
AREA
2-1"0
1#6 TO GROUNDING
ELECTRODE SYSTEM
24"
2-20
2-2"0
ALT. 3
PROJECT TELECOMMUNICATION
POINT OF CONNECTION
REVISIONS
DATE
INITIALS
INTERIOR RISER DIAGRAM
HIGH RISE BUILDING CATV
RESIDENTIAL (TYPICAL)
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Building Roof
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
APARTMENTS
APARTMENTS
Floor Level
5-1" 0
5-1 0
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
TTC
APARTMENTS
APARTMENTS
Floor Level
5-1" 0
5-1 Ø
#1
#2
#3
#4
#5
#6 #7 #8 #9 #10
2-2" 01
APARTMENTS
APARTMENTS
Floor Level
5-1" 0
5-1 Ø
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
TTC
APARTMENTS
APARTMENTS
Floor Level
5-1"
5-1 0
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
2-2"
APARTMENTS
APARTMENTS
Floor Level
2-1" 0
5-1" 0
5-1" 0
1-1" 0
GUARD
8' X 3/4" WOOD
PANEL BOARD
MTTC
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
ADMIN OFFICE
COMMUNAL AREA
GROUND LEVEL
1 #6 AWG THW SOLID
LEGEND
24"
8'X5/8" GROUND ROD
36" X 24" X 6" METAL
TTC
TO TELECOMMUNICATIONS
CABINET W/3/4" PLYWOOD
DISTRIBUTION BOX
BACKBOARD
2-4"0
4" X 4" X 2-1/8" FLUSH
NOTES:
MOUNTED WALL TELEPHONE
1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM
OUTLET W/COVER PLATE
SHALL BE PROVIDED WITH OUTLETS FOR TELEPHONE
4" X 2" X 2-1/8" FLUSH MOUNTED
SERVICE.
WALL TELEPHONE OUTLET W/COVER
2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF
PLATE
3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN
DRAWINGS.
REVISIONS
DATE
INITIALS
INTERIOR TEL. 20 OR LESS APTS
3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS
CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER
DISTRIBUTION RISER DIAGRAM
OUTLETS SHALL BE 4" X 2" X 2-1/8".
RESIDENTIAL BLDG. (TYPICAL)
4. THE MINIMUM SIZE FOR TELEPHONE CABINETS SHALL BE
36" X 24" X 6" AND SHALL SERVE NO MORE THAN 20 UNITS.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Building Roof
APARTMENTS
APARTMENTS
#1 #2 #3 #4 #5 #6 #7
#8 #9 #10 #11 #12 #13 #14 #15
8-1" 0
7-1".
#8 #9 #10 #11 #12 #13 #14 #15
TTC
#1 #2 #3 #4 #5 #6 #7
TTC
7-1"
#8 #9 #10 #11 #12 #13 #14 #15
#1 #2 #3 #4 #5 #6 #7
7-1" 0
#1 #2 #3 #4 #5 #6 #7
#8 #9 #10 #11 #12 #13 #14 #15
TTC
TTC
2-2" 0
#1 #2 #3 #4 #5 #6 #7 #8
#9 #10 #11 #12 #13 #14 #15 #16
TTC
WOOD PANNEL
8-1"0
ADMIN OFFICE
GUARD
COMMUNAL AREA
5-1" Ø
MTTC
3-1" 0
GROUND LEVEL
1 #6 AWG THW SOLID
8'X 5/8" GROUND ROD
24"
2-2"0
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
LEGEND
TTC
36" X 24" X 6" METAL
CABINET W/ 3/4" PLYWOOD
BACKBOARD
4" X 4" X 2-1/8" FLUSH
NOTES:
MOUNTED WALL TELEPHONE
1. THE KITCHEN. LIVING ROOM AND EACH BEDROOM
OUTLET W/COVER PLATE
SHALL BE PROVIDED WITH OUTLETS FOR TELEPHONE
SERVICE
4" X 2" X 2-1/8" FLUSH MOUNTED
2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF
ALT. 1
WALL TELEPHONE OUTLET W/COVER
PLATE
3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN
DRAWINGS.
REVISIONS
DATE
INITIALS
INTERIOR TEL. MORE THAN 20
3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS
CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER
APTS DISTRIBUTION RISER DIAGRAM
OUTLETS SHALL BE 4" X 2" X2-1/8".
RESIDENTIAL BLDG. (TYPICAL)
4. THE MINIMUM SIZE FOR TELEPHONE CABINETS SHALL BE
36" X 24"X 6" AND SHALL SERVE NO MORE THAN 20 UNITS.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Buikling Roof
#1 #2 #3 #4 #5 #6 #7 #8
#9 #10 #11 #12 #13 #14 #15 #16
TTC
Roor Level
8-1" 0
B-1
#1 #2 #3 #4 #5 #6 #7 #8
#9 #10 #11 #12 #13 #14 #15 #16
TTC
Floor Level
8-1"
8-1 0
#1 #2 #3 #4 #5 #6 #7 #8
#9 #10 #11 #12 #13 #14 #15 #16
TTC
Floor Level
8-1" 0
8-1
#1 #2 #3 #4 #5 #6 #7 #8
#9 #10 #11 #12 #13 #14 #15 #16
TTC
Floor Level
8-1"
8-1
#1 #2 #3 #4 #5 #6 #7 #8
#9 #10 #11 #12 #13 #14 #15 #16
2-2"0
Floor Level
4-1" 0
8-1"
8-1"0
3-1" 0
GUARD
8' X X 3/4" WOOD
PANEL BOARD
MTTC
ADMIN OFFICE
COMMUNAL AREA
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
GROUND LEVEL
1 #6 AWG THW SOLID
LEGEND
24"
8' X 5/8" GROUND ROD
36" X 24" X 6" METAL
TO TELECOMMUNICATIONS
TTC
DISTRIBUTION BOX
CABINET W/3/4" PLYWOOD
BACKBOARD
2-4"0
NOTES:
4" X 4" X 2-1/8" FLUSH
MOUNTED WALL TELEPHONE
1. THE KITCHEN, LIVING ROOM AND EACH BEDROOM
OUTLET W/COVER PLATE
SHALL BE PROVIDED WITH OUTLETS FOR TELEPHONE
SERVICE.
4" X 2" X 2-1/8" FLUSH MOUNTED
2. THE INTERIOR CONDUITS SHALL HAVE A MINIMUM OF
ALT. 2
WALL TELEPHONE OUTLET W/COVER
PLATE
3/4" UNLESS ANOTHER DIAMETER IS SPECIFIED IN
DRAWINGS.
REVISIONS
DATE
INITIALS
3. OUTLES DIRECTLY CONNECTED TO TELECOMMUNICATIONS
INTERIOR TEL. - MORE THAN 20
CABINETS SHALL BE 4" X 4" X 2-1/8" (MIN), ALL OTHER
APTS DISTRIBUTION RISER DIAGRAM
OUTLETS SHALL BE 4" X 2" X2-1/8".
4. THE MINIMUM SIZE FOR TELEPHONE CABINETS SHALL BE
RESIDENTIAL BLDG. (TYPICAL)
36" X 24" X 6" AND SHALL SERVE NO MORE THAN 20 UNITS.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
ROOF
PENTHOUSE
SECOND LEVEL
APT.
APT.2
APT.3
APT.4
APT.5
APT.8
APT.7
APT.8
2-1"0
2-1*0
2-1"0
PENTHOUSE
2-1"0
TTC
TTC
FIRST LEVEL
APT.1 APT.2
APT.3 APT.4
APT.5 APT.6
APT.7
APT.8
2-1"0
2-10
2-1*0
2-1"0
4TH. LEVEL
APT.1 APT.2
APT.3
APT.4
APT.5
APT.6
APT.7
APT.8
2-1"0
2-1"0
2-1"0
2-1"
3RD. LEVEL
2-2"0
2-2"0
APT.1 APT.2
APT.3
APT.4
APT.5
APT.6
APT.7
APT.8
2-1"0
2-1"0
2-1"0
2.10
2ND. LEVEL
TTC
TTC
APT.1 APT.2
APT.3
APT.4
APT.5
APT.6
APT.7
APT.8
2-1*0
2-10
2-1"0
2-1*0
1ST LEVEL
2-2"0
2-2"0
SEE: ONE LINE
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
DIAGRAM DETAIL
PARKING
ADMINISTRATION
OFFICE
M
GROUND LEVEL
1-1"0
GUARD
COMUNAL
AREA
2-1"0
1#6 TO GROUNDING
ELECTRODE SYSTEM
24"
2-4"0
2-2"0
PROJECT TELECOMMUNICATION
ALT. 3
POINT OF CONNECTION
TELEPHONE INTERIOR RISER DETAIL
HIGH RISE BUILDING RESIDENTIAL
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Road
APT. 1 APT.2
APT.3
APT.4
APT.1 APT.2
APT.3 APT.4
I1
Fifth Level
2-1"0
2-1"0
2-1"0
2-1"0
CATV
TTC
APT.1 APT.2
APT.3 APT.4 APT.1 APT.2
APT.3 APT.4
Fourth Level
2-1"0
2-1"0
2-1"0
2-1"0
APT.1 APT.2
APT.3 APT.4 APT.1 APT.2
APT.3 APT.4
$
11
11
Third Level
2-1"0
2-1"0
2-1*0
2-1"0
2-2"0
2-2*0
APT.1 APT.2
APT.3 APT.4 APT.1 APT.2
APT.3 APT.4
1
X
$
Second Level
2-1"0
2-1"0
2-1"0
2-1"0
CATV
APT.2
TTC
APT.1
APT.3
APT.4
APT.1
APT.2
APT.3 APT.4
If
First Level
2-1"0
2-1*0
2-1"0
2-1"0
36" X 30" X 6' MIN
CABINET
SEE ONE LINE DIAGRAM
SEE ONE LINE DIAGRAM
2-2"0
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
24"
11#6 AWG THW SOLID
2-2"D
E
TELECOMMUNICATIONS
2-4"0
DISTRIBUTION BOX
REVISIONS
DATE
INITIALS
INTERIOR RISER DIAGRAM
WALK-UPS (TYPICAL)
CATV TELEPHONE
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
BLDG #3
BLDG #2
BLDG #1
TEL
TEL
TEL
TEL
TEL
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos-con con fines ilustrativos. La JRTPR se
2-4"0
TEL
4-4"0
2-2" 0
2-2" 0
2 4"0
2-4"0
SPLICING BOX
BLDG #4
SPLICING BOX
7' X 4' 6" X 4'
TO POINT OF CONECTION
7' X 4' 6" X 4"
TEL
4-4"0
2-4"0
TEL
TELEPHONE INFRAESTRUCTURE
W-UPS DIAGRAM (TYPICAL)
A
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
BLDG #2
BLDG #1
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
CTC
CTC
CTC
CTC
1-2" ø PVC
1-2" 0 PVC
BLDG. # 3
CTC
1-2"0
1-2"0
-2-2" 0
1-2" 0 PVC
1-2"0 PVC
2-2' Ø PVC
2-2" 0->
2-2" 0 PVC
POINT OF CONNECTION
CTC
CATV INFRAESTRUCTURE
W-UPS DIAGRAM (TYPICAL)
A
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
SECCION G
DETALLES TÍPICOS GABINETES
Tabla de Requerimientos
Detalles Típicos Paneles de Distribución
Edificios Comerciales
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
Detalles Típicos Gabinetes en Metal
TELECOMMUNICATIONS ROOMS
WITH PLYWOOD PANELS
8' X 4' X 3/4"
TELEPHONE PANELS
CATV PANELS
THIRD LEVEL
CAPPED
CAPPED
FLOOR
2-4" 0
2-2" 0
SECOND LEVEL
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
CAPPED
CAPPED
FLOOR
2-4" 0
2-2" 0
MAIN TELEPHONE
MAIN CATV
PANEL
PANEL
FIRST LEVEL
CAPPED
CAPPED
FLOOR
3 4" 0 PVC
2 2" Ø PVC
TO TELECOMMUNICATION
POINT OF CONNECTION
TELECOMMUNICATIONS ROOMS
INTERCONNECTION COMMERCIAL
BUILDINGS (TYPICAL)
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
6"
30"/24"
PLYWOOD PANEL 3/4"
36"
1" Ø CONDUITS (MIN)
2 COND. 4" 0
PVC SCH 26 (MIN)
CATV/TELEPHONE CABINET
NTS
30"/24"
6"
PLYWOOD PANEL 3/4"
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
36"
1" Ø CONDUITS (MIN)
2 COND. 2" Ø
PVC SCH 26 (MIN)
CATV/TELEPHONE CABINETS
CABINETS WILL BE EQUIPPED WITH A S/4" PLYWOOD
BACKBOARD, A HINGED DOOR WITH LATCH AND KEY
AND SHALL HAVE COMPLETE FRONTAL ACCESS. THE
CABINETS SHALL ALSO PROVIDE FOR THE PROPER
BONDING AND GROUNDING OF THE
TELECOMMUNICATIONS FACILITIES.
REVISIONS
DATE
INITIALS
METAL CABINETS WALL MOUNTED
CONDUITS TERMINATIONS
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
o
RAINTIGHT
30"/24"
6"
COVER
o
o
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
HANDLE
HANDLE
36"
PADLOCK
HINGED
DOOR
PADLOCK
SIDE VIEW
ISOMETRIC VIEW
AS REQUIRED
FRONT VIEW
SPECIFICATIONS:
1. CABINET MUST COMPLY WITH NEMA SPECIFICATIONS.
2. MATERIAL CLEANED AND DEGREASED PRIOR TO PAINT.
3. FINISH: ANSI #61 DRY. 155E115-U GRAY POLYESTER
POWDER COATING.
4. FLUSH WITH PLYWOOD BACKBOARD 3/4" THICK
5. MATERIAL TO #12 GALVANIZE STEEL 304
6. MINIMUN STANDARDS TO NEMA TYPE 2
DESIGNATION SPECIFICATIONS.
REVISIONS
DATE
INITIALS
METAL CABINET WALL
MOUNTED SPECIFICATIONS
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
EXTERIOR WALL METALLIC
INTERIOR METALLIC
BOXES 4" X 4" X 2-1/8"
BOXES 4" X 2" X 2-1/8"
INTERIOR METALLIC
3/4" 0
3/4" 0
BOXES 4" X 2" X 2-1/8"
3/4"0 CONDUIT FOR
COMMON GROUND
3/4" 0
1" Ø CONDUIT TO TELEPHONE
DISTRIBUTION BOX
1" Ø CONDUIT TO CATV
DISTRIBUTION POINT
IN PLANTING STRIP
OUTER WALL
TYPICAL
EXTERIOR METALLIC
BOX 4" X 4" X 2-1/8"
RIGHT OF WAY
24" TO 30"
INSIDE FINISHED FLOOR
16"
6"
TELEPHONE
2-1"0 PVC. 14"
DISTRIBUTION
3/4" 0 FOR
BOX
GND WIRE
TO CATV DISTRIBUTION
POINT IN PLANTING STRIP
NOTE:
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
60"
TWO 4" X 2" X 2-1/8" METALLIC BOXES FOR
TELEPHONE AND CATV SERVICE WILL BE
INSTALLED IN EACH BEDROOM, KITCHEN AND
LIVING ROOM, CONNECTED TO THE
CORRESPONDING SYSTEM WITH A 3/4" Ø CONDUITS.
TELECOMMUNICATIONS
METALLIC BOXES &
INDIVIDUAL CONDUITS DETAIL
Los detalles incluidos en los Apéndices son ejemplos con fines ilustrativos. La JRTPR se
reserva el derecho de enmendar los mismos conforme las necesidades del servicio.
SECCION H
FORMULARIOS
Forma JRTPR F-101 Solicitud de Servicios para
Endoso
Forma JRTPR F-102 Solicitud de Endoso de
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
Obras Construidas
Forma JRTPR F-103 Solicitud de Asignación de
Infraestructura
Forma JRTPR F-104 Solicitud de Endoso A
Proyectos de Relocalizacion de Infraestructura
SECCION I
MODELOS DE ESCRITURA
Escritura Modelo Proyecto Comercial
JUNTA REGLAMENTADORA DE TELECOMUNICACIONES DE PUERTO RICO
Escritura Modelo Proyecto Urbanizació y Walk-ups