Regl. 1279, art. 1000.1c
Reglamento General de Seguridad e Higiene Industrial, Cap. VI -- Montacargas de Trabajadores. No incluido en el Ãndice bajo la Ley Núm. 149 de 12 dic, 2005
Cite as Reglamento Núm. 1279, Art. 1000.1c
Guide rails, except those of elevators equipped
with: oller or other type guiding members. not requiring
lubrication, should be kept well lubricated; but an
excess of lubricant should be avoided.
Rails on which a lubricant is used should be
cleaned down at least once a year. Where necessary,
a non-flammable or high-flash-point solvent should
be used to remove excess lubricant, lint, and dirt
which will accumulate on them, and which presents a
hazard in case of fire in the hoistway.
Where sliding-type safeties are used it is important that guide-rails lubricant, or prelubricated or
impregnated guide-shoe gibs where used, be of a type
recommended by the manufacturer of the elevator which
will not reduce the holding power of the car safety
(See Part II, Section 205, Rule 205.16.)
Rust-preventive compounds such as paint, mixtures
of graphite and oil, and similar coatings should not
be used as they may interfere with and in many cases
will prevent proper operation of the car safety.
Some substances may even cause complete failure of the
safety to function. If it is considered necessary
for any reason to use any of these substances, the
manufacturer of the elevator should be consulted before
applying it.
1000.1d - Oil Buffers