Regl. 1279, art. 105.2b
Reglamento General de Seguridad e Higiene Industrial, Cap. VI -- Montacargas de Trabajadores. No incluido en el Ãndice bajo la Ley Núm. 149 de 12 dic, 2005
Cite as Reglamento Núm. 1279, Art. 105.2b
and Sheaves Not Located Directly Over the Hoistway.
For machines and sheaves located below or at
the sides of the hoistway, the foundation for the
machine and sheave beams and their supports shall
be designed to withstand the following loads:
1. The foundation shall support the total
weight of the machine, sheaves and other equipment,
and the floor if any.
2. The sheave beams and the foundation bolts
shall withstand twice the vertical components of
the tensions in all hoisting ropes passing over
sheaves or drums of the foundation or beams, less
the weight of the machine or sheaves.
3. The sheave beams and the foundation bolts
shall withstand twice the horizontal component, if
any, of the tensions in all hoisting rope passing
over sheaves or drums on the foundation or beams.
4. The foundation shall withstand twice the
overturning moment, if any, developed by the tensions in all the hoisting ropes passing over sheaves
or drums on the foundation beams.