OCCUPANT LOAD
Length: 147 wordsOfficial source
Cite as Reglamento Núm. 9049, Art. 107-1004
1004.7 Outdoor areas. Yards, patios, occupied roofs, courts and similar outdoor areas accessible
to and usable by the building occupants shall be provided with means of egress as required by this
chapter. The occupant load of such outdoor areas shall be assigned by the registered design
professional and the fire code official in accordance with the anticipated use. Where outdoor areas
are to be used by persons in addition to the occupants of the building, and the path of egress travel
from the outdoor areas passes through the building, means of egress requirements for the building
shall be based on the sum of the occupant loads of the building plus the outdoor areas.
Exceptions:
1. Outdoor areas used exclusively for service of the building need only have one means of
egress.
2. Both outdoor areas associated with Group R-3 and individual dwelling units of Group R-2.