Regl. 9049, art. 107-1004 dup2
OCCUPANT LOAD
Length: 147 wordsOfficial source
Cite as Reglamento Núm. 9049, Art. 107-1004 dup2
[BE]1004.7 Outdoor areas. Yards, patios, occupied roofs, courts and similar outdoor areas
accessible to and usable by the building occupants shall be provided with means of egress as
required by this chapter. The occupant load of such outdoor areas shall be assigned by the
registered design professional and the fire code official in accordance with the anticipated use.
Where outdoor areas are to be used by persons in addition to the occupants of the building, and
the path of egress travel from the outdoor areas passes through the building, means of egress
requirements for the building shall be based on the sum of the occupant loads of the building plus
the outdoor areas.
Exceptions:
1. Outdoor areas used exclusively for service of the building need only have one means of
egress.
2. Both outdoor areas associated with Group R-3 and individual dwelling units of Group
R-2.
728