Regl. 9049, art. 107-1006
NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
Length: 399 wordsOfficial source
Cite as Reglamento Núm. 9049, Art. 107-1006
TABLE 1006.2.1
SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
MAXIMUM COMMON PATH OF EGRESS
TRAVEL DISTANCE(feet)
MAXIMUM
Without Sprinkler
OCCUPANCY
OCCUPANT
System
With Sprinkler
LOAD OF SPACE
(feet)
System
Occupant Load
(feet)
OL ≤ 30
OL > 30
Aᶜ, E, M
49
75
75
75ª
B
49
100
75
100ᵃ
F
49
75
75
100ᵃ
H-1, H-2, H-3
3
NP
NP
25ᵇ
H-4, H-5
10
NP
NP
75ᵇ
I-1, I-2ᵈ, I-4
10
NP
NP
75ª
I-3
10
NP
NP
100ᵃ
R-1
10
NP
NP
75ª
R-2
30
75
NP
125ᵃ
R-3ᵉ
20
75
NP
125 a, g
R-4ᵉ
20
NP
NP
125ᵃ, g
Sf
29
100
75
100ᵃ
U
49
100
75
75ª
For SI: 1 foot 304.8 mm.
NP = Not Permitted.
a.
Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. See Section 903 for occupancies where automatic sprinkler systems are
permitted in accordance with Section 903.3.1.2.
b.
Group H occupancies equipped throughout with an automatic sprinkler system in accordance with Section 903.2.5.
c.
For a room or space used for assembly purposes having fixed seating, see Section 1029.8.
d.
For the travel distance limitations in Group I-2, see Section 407.4.
e.
The common path of egress travel distance shall only apply in a Group R-3 occupancy located in a mixed occupancy building.
f.
The length of common path of egress travel distance in a Group S-2 open parking garage shall be not more than 100 feet.
on
For the travel distance limitations in Groups R-3 and R-4 equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.3, see Section 1006.2.2.6
120
TABLE 1006.3.3(1)
STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
MAXIMUM
MAXIMUM
NUMBER OF
COMMON
STORY
OCCUPANCY
DWELLING
PATH OF
UNITS PER
TRAVEL
STORY
DISTANCE
Basement, first, second, third, or
R-2 a, b
4 dwelling units
125 feet
fourth story above grade plane
Fifth story above grade plane and
NP
NA
NA
higher
For SI: 1 foot 3048 mm.
NP = Not Permitted.
NA = Not Applicable.
a.
Buildings classified as Group R-2 equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2 and provided with emergency escape and rescue
openings in accordance with Section 1030.
b.
This table is used for R-2 occupancies consisting of dwelling units. For R-2 occupancies consisting of sleeping units, use Table 1006.3.3(2).