Regl. 9049, art. 107-1006 dup2

NUMBER OF EXITS AND EXIT ACCESS DOORWAYS

Length: 401 wordsOfficial source

Cite as Reglamento Núm. 9049, Art. 107-1006 dup2

[BE] TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE(feet) MAXIMUM Without Sprinkler OCCUPANCY OCCUPANT System With Sprinkler LOAD OF SPACE (feet) System Occupant Load (feet) OL ≤ 30 OL > 30 Aᶜ, E, M 49 75 75 75ª B 49 100 75 100ᵃ F 49 75 75 100ᵃ H-1, H-2, H-3 3 NP NP 25ᵇ H-4, H-5 10 NP NP 75ᵇ I-1, I-2ᵈ, I-4 10 NP NP 75ª I-3 10 NP NP 100ᵃ R-1 10 NP NP 75ª R-2 30 75 NP 125ᵃ R-3ᵉ 20 75 NP 125 a, g R-4ᵉ 20 NP NP 125ᵃ, g Sf 29 100 75 100ᵃ U 49 100 75 75ª For SI: 1 foot = 304.8 mm. NP = Not Permitted. b. Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. See Section 903 for occupancies where automatic sprinkler systems are permitted in accordance with Section 903.3.1.2. c. Group H occupancies equipped throughout with an automatic sprinkler system in accordance with Section 903.2.5. d. For a room or space used for assembly purposes having fixed seating, see Section 1029.8. e. For the travel distance limitations in Group I-2, see Section 407.4. f. The common path of egress travel distance shall only apply in a Group R-3 occupancy located in a mixed occupancy building. on The length of common path of egress travel distance in a Group S-2 open parking garage shall be not more than 100 feet. h. For the travel distance limitations in Groups R-3 and R-4 equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.3, see Section 1006.2.2.6 729 [BE]TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES MAXIMUM MAXIMUM NUMBER OF COMMON PATH OF STORY OCCUPANCY DWELLING UNITS TRAVEL PER STORY DISTANCE Basement, first, second, third, or R-2 a, b 4 dwelling units 125 feet fourth story above grade plane Fifth story above grade plane and NP NA NA higher For SI: 1 foot 3048 mm. NP = Not Permitted. NA = Not Applicable. b. Buildings classified as Group R-2 equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2 and provided with emergency escape and rescue openings in accordance with Section 1030. c. This table is used for R-2 occupancies consisting of dwelling units. For R-2 occupancies consisting of sleeping units, use Table 1006.3.3(2).
Regl. 9049, art. 107-1006 dup2: NUMBER OF EXITS AND EXIT ACCESS DOORWAYS | Justis AI