Regl. 9049, art. 107-117
DEMOLITION
Length: 2,715 wordsOfficial source
Cite as Reglamento Núm. 9049, Art. 107-117
[A]117.1 General. The code official shall order the owner or owner's authorized agent of any
premises on which is located any structure that in the code official's judgment is so old or
dilapidated, or has become so out of repair as to be dangerous, unsafe, insanitary or otherwise
unfit for human habitation of occupancy, and such that it is unreasonable to repair the structure,
to demolish and remove such structure; or if such structure is capable of being made safe by
repairs, to repair and make safe and sanitary or to demolish and remove to the owner's or the
826
owner's authorized agent's option; or where there has been a cessation of normal construction of
any structure for a period of more than two years, to demolish and remove such structure.
[A]117.2 Notices and orders. Notices and orders shall comply with Section 113.
[A]117.3 Failure to comply. If the owner or the owner's authorized agent of a premises fails to
comply with a demolition order within the time prescribed, the code official shall cause the
structure to be demolished and removed, either through an available public agency or by contract
or arrangement with private persons, and the cost of such demolition and removal shall be charged
against the real estate on which the structure is located and shall be a lien on such real estate.
[A]117.4 Salvage materials. Where any structure has been ordered demolished and removed, the
governing body or other designated officer under said contract or arrangement aforesaid shall have
the right to sell the salvage and valuable materials at the highest price obtainable. The net proceeds
of such sale, after deducting the expenses of such demolition and removal, shall be promptly
remitted with a report of such sale or transaction, including the items of expense and the amounts
deducted, for the person who is entitled thereto, subject to any order of a court. If such a surplus
does not remain to be turned over, the report shall so state.
CHAPTER 2 - DEFINITIONS
SECTION 201 - GENERAL
201.1 Scope. Unless otherwise expressly stated, the following words and terms shall, for the
purposes of this code, have the meanings shown in this chapter.
201.2 Interchangeability. Words used in the present tense include the future; words stated in the
masculine gender include the feminine and neuter; the singular number includes the plural and the
plural, the singular.
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined in
the other Puerto Rico Codes, such terms shall have the meanings ascribed to them in those codes.
201.4 Terms not defined. Where terms are not defined through the methods authorized by this
chapter, such terms shall have ordinarily accepted meanings such as the context implies.
SECTION 202 - GENERAL DEFINITIONS
[AJADDITION. An extension or increase in floor area, number of stories, or height of a building
or structure.
[AJADMINISTRATIVE JUDGE. The director of the Administrative Revisions Division, as
establish by Act 161-2009, as amended.
827
[AJALTERATION. Any construction or renovation to an existing structure other than a repair
or addition.
[AJAPPROVED. Acceptable to the code official.
[AJBUILDING. Any structure utilized or intended for supporting or sheltering any occupancy.
[A]BUILDING OFFICIAL. The Auxiliary Secretary of the Permits Management Office of the
Department of Economic Development and Commerce (OGPe-DDEC), or a duly authorized
representative.
[A]CHANGE OF OCCUPANCY. A change in the use of a building or a portion of a building that
results in any of the following:
1. A change of occupancy classification.
2. A change from one group to another group within an occupancy classification.
3. Any change in use within a group for which there is a change in application of the
requirements of this code.
[A]CODE OFFICIAL. The officer or other designated authority charged with the administration
and enforcement of this code.
[BS]DANGEROUS. Any building, structure or portion thereof that meets any of the conditions
described below shall be deemed dangerous:
1. The building or structure has collapsed, has partially collapsed, has moved off its
foundation, or lacks the necessary support of the ground.
2. There exists a significant risk of collapse, detachment or dislodgement of any portion,
member, appurtenance or ornamentation of the building or structure under service
loads.
[AJDEFERRED SUBMITTAL. Those portions of the design that are not submitted at the time
of the application and that are to be submitted to the code official within a specified period.
DESIGNATED INSPECTOR. An individual who is licensed to practice the profession of
Architecture or Engineering as defined by the provisions of the Act No. 173 of August12, 1988,
as amended, and according to with the provisions of Act No. 135 of June 15, 1967, as amended,
(Certification Law); appointed by the owner to make periodic inspections of the construction work
for which a permit was issued by the building official to ascertain compliance with the approved
construction documents and permit issued. The professional shall certify the required inspections
before the building official issue the certificate of occupancy.
[BS|DISPROPORTIONATE EARTHQUAKE DAMAGE. A condition of earthquake-related
damage where both of the following occur:
1. The 0.3-second spectral acceleration at the building site as estimated by the United States
828
Geological Survey for the earthquake in question is less than 40 percent of the mapped
acceleration parameter SS.
2. The vertical elements of the lateral force-resisting system have suffered damage such
that the lateral load carrying capacity of any story in any horizontal direction has been
reduced by more than 10 percent from its pre-damage condition.
EQUIPMENT OR FIXTURE. Any plumbing, heating, electrical, ventilating, air conditioning,
refrigerating, and fire protection equipment, and elevators, dumbwaiters, escalators, boilers,
pressure vessels and other mechanical facilities or installations that are related to building services.
Equipment or fixture shall not include manufacturing, production, or process equipment, but shall
include connections from building service to process equipment.
[AJEXISTING BUILDING. A building erected prior to the date of adoption of the appropriate
code, or one for which a legal building permit has been issued.
[AJEXISTING STRUCTURE. A structure erected prior to the date of adoption of the appropriate
code, or one for which a legal building permit has been issued.
[AJFACILITY. All or any portion of buildings, structures, site improvements, elements and
pedestrian or vehicular routes located on a site.
[BS]FLOOD HAZARD AREA. The greater of the following two areas:
1. The area within a flood plain subject to a 1-percent or greater chance of flooding in any
year.
2. The area designated as a flood hazard area on a community's flood hazard map, or
otherwise legally designated.
GOVERNMENT
AGENCIES
WITH
JURISDICTION.
Defined
as
"Entidad Gubernamental Concernida" in the Joint Regulation.
[A]HISTORIC BUILDINGS OR PROPERTY. Any building or structure site, object, place,
location, district or zone, or collection of structures and their associated sites, deemed of
importance to the history, architecture or culture of an area by an appropriate local, state or
federal governmental jurisdiction and as defined by the "Reglamento Conjunto para la
Evaluación y Expedición de Permisos Relacionados al Desarrollo, Uso de Terrenos y Operación
de Negocios (Reglamento Conjunto), según la Ley Número 161 De 2009, según enmendada".
This includes historical buildings or properties:
1. Listed or certified as eligible for listing by the State Historic Preservation Officer or
the Keeper of the National Register of Historic Places, in the National Register of
Historic Places.
2. Designated as historic or having historic significance under an applicable state or local
law, ordinance or resolution.
829
3. Designated as historic or having historic significance by the Puerto Rico Planning
Board in the Register of Historic Places and Zones, Board of Directors of the Institute
of Puerto Rican Culture, and the Puerto Rico Legislative Assembly.
4. Certified as a contributing or eligible resource within a National Register, state
designated or locally designated historic district or zone.
(JOINT REGULATION) JOINT PERMITS REGULATIONS FOR THE EVALUATION
AND ISSUANCE OF PERMITS RELATED TO DEVELOPMENT, LAND USE AND
BUSINESS OPERATION. As defined in the "Reglamento Conjunto de Permisos para Obras de
Construcción y Uso de Terrenos de Puerto Rico, (Reglamento Conjunto)" as established by the
Act No. 161 of December 1, 2009, "Ley para la Reforma del Proceso de Permisos de Puerto Rico,
as amended".
[BINONCOMBUSTIBLE MATERIAL. A material that, under the conditions anticipated, will
not ignite or burn when subjected to fire or heat. Materials that pass ASTM E136 are considered
noncombustible materials.
(OGPe-DDEC) Permits Management Office: As defined in the Act 141, of July 10, 2018, "Ley
de Ejecución del Plan de Reorganización del Departamento de Desarrollo Económico y
Comercio".
PRIMARY FUNCTION. A primary function is a major activity for which the facility is intended.
Areas that contain a primary function include, but are not limited to, the customer services lobby
of a bank, the dining area of a cafeteria, the meeting rooms in a conference center, as well as offices
and other work areas in which the activities of the public accommodation or other private entity
using the facility are carried out. Mechanical rooms, boiler rooms, supply storage rooms, employee
lounges or locker rooms, janitorial closets, entrances, corridors and restrooms are not areas
containing a primary function.
(PRPB) PUERTO RICO PLANNING BOARD - Government Agency created by ACT No. 75
of June 1975 as amended, hereinafter PRPB. In addition, it is the State Agency Coordinator of the
National Flood Insurance Program.
[AJREGISTERED DESIGN PROFESSIONAL. An individual who is licensed to practice the
profession of architect or engineer as defined by the provisions of the Act No. 173 of August 12,
1988, as amended, and according to with the provisions of Act No. 135 of June 15, 1967, as
amended, (Certification Law); engaged by the owner to prepare the construction documents, make
application to the building official and obtain the required permit.
[AJREGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. A registered
design professional engaged by the owner or the owner's authorized agent to review and coordinate
certain aspects of the project, as determined by the code official, for compatibility with the design
of the building or structure, including submittal documents prepared by others, deferred submittal
documents and phased submittal documents.
REHABILITATION. Any work, as described by the categories of work defined herein,
830
undertaken in an existing building.
RELOCATABLE BUILDING. A partially or completely assembled building constructed and
designed to be reused multiple times and transported to different building sites.
[AJREPAIR. The reconstruction, replacement or renewal of any part of an existing building for
the purpose of its maintenance or to correct damage.
[BSJREROOFING. The process of recovering or replacing an existing roof covering. See "Roof
recover" and "Roof replacement."
[BS]RISK CATEGORY. A categorization of buildings and other structures for determination of
flood, wind, snow, ice and earthquake loads based on the risk associated with unacceptable
performance, as provided in Section 1604.5 of the Puerto Rico Building Code.
[BS]ROOF COATING. A fluid-applied adhered coating used for roof maintenance, roof repair,
or as a component of a roof covering system or roof assembly.
[BS]ROOF RECOVER. The process of installing an additional roof covering over a prepared
existing roof covering without removing the existing roof covering.
[BS]ROOF REPAIR. Reconstruction or renewal of any part of an existing roof for the purpose of
correcting damage or restoring the predamage condition.
[BS]ROOF REPLACEMENT. The process of removing the existing roof covering, repairing any
damaged substrate and installing a new roof covering.
[BS]SEISMIC FORCES. The loads, forces and requirements prescribed herein, related to the
response of the building to earthquake motions, to be used in the analysis and design of the
structure and its components. Seismic forces are considered either full or reduced, as provided in
Chapter 3.
[BS]SUBSTANTIAL DAMAGE. For the purpose of determining compliance with the flood
provisions of this code, damage of any origin sustained by a structure whereby the cost of restoring
the structure to its before-damaged condition would equal or exceed 50 percent of the market value
of the structure before the damage occurred.
[BS]SUBSTANTIAL IMPROVEMENT. For the purpose of determining compliance with the
flood provisions of this code, any repair, alteration, addition, or improvement of a building or
structure, the cost of which equals or exceeds 50 percent of the market value of the structure, before
the improvement or repair is started. If the structure has sustained substantial damage, any repairs
are considered substantial improvement regardless of the actual repair work performed. The term
does not, however, include either of the following:
1. Any project for improvement of a building required to correct existing health, sanitary,
or safety code violations identified by the code official and that is the minimum
831
necessary to ensure safe living conditions.
2. Any alteration of a historic structure, provided that the alteration will not preclude the
structure's continued designation as a historic structure.
[BS]SUBSTANTIAL STRUCTURAL ALTERATION.
An alteration in which the gravity load-carrying structural elements altered within a 5-year period
support more than 30 percent of the total floor and roof area of the building or structure. The areas
to be counted toward the 30 percent shall include mezzanines, penthouses, and in-filled courts and
shafts tributary to the altered structural elements.
[BS]SUBSTANTIAL STRUCTURAL DAMAGE. A condition where any of the following
apply:
1. The vertical elements of the lateral force-resisting system have suffered damage such
that the lateral load carrying capacity of any story in any horizontal direction has been
reduced by more than 33 percent from its predamage condition.
2. The capacity of any vertical component carrying gravity load, or any group of such
components, that has a tributary area more than 30 percent of the total area of the
structure's floor(s) and roof(s) has been reduced more than 20 percent from its
predamage condition, and the remaining capacity of such affected elements, with respect
to all dead and live loads, is less than 75 percent of that required by the Puerto Rico
Building Code for new buildings of similar structure, purpose and location.
3. The capacity of any structural component carrying snow load, or any group of such
components, that supports more than 30 percent of the roof area of similar construction
has been reduced more than 20 percent from its predamage condition, and the remaining
capacity with respect to dead, live and snow loads is less than 75 percent of that required
by the Puerto Rico Building Code for new buildings of similar structure, purpose and
location.
TECHNICALLY INFEASIBLE. An alteration of a facility that has little likelihood of being
accomplished because the existing structural conditions require the removal or alteration of a loadbearing member that is an essential part of the structural frame, or because other existing physical
or site constraints prohibit modification or addition of elements, spaces or features which are in
full and strict compliance with the minimum requirements for new construction and which are
necessary to provide accessibility.
TEMPORARY POWER. The code official is authorized to give permission to temporarily
supply and use power in part of an electric installation before such installation has been fully
completed and the final certificate of completion has been issued. The part covered by the
temporary certificate shall comply with the requirements specified for temporary lighting, heat or
power in NFPA 70 and the Puerto Rico Electric Power Authority's Reglamento Complementario
al Código Eléctrico Nacional (Complementary Code). In case of a conflict between the
Complementary Code and the NFPA 70, the Complementary Code will prevail.
832
UNSAFE. Buildings, structures or equipment that are unsanitary, or that are deficient due to
inadequate means of egress facilities, inadequate light and ventilation, or that constitute a fire
hazard, or in which the structure or individual structural members meet the definition of
"Dangerous," or that are otherwise dangerous to human life or the public welfare, or that involve
illegal or improper occupancy or inadequate maintenance shall be deemed unsafe. A vacant
structure that is not secured against entry shall be deemed unsafe.
WORK AREA. That portion or portions of a building consisting of all reconfigured spaces as
indicated on the construction documents. Work area excludes other portions of the building where
incidental work entailed by the intended work must be performed and portions of the building
where work not initially intended by the owner is specifically required by this code.
CHAPTER 3 - PROVISIONS FOR ALL COMPLIANCE
METHODS.
No amendments
CHAPTER 4 - REPAIRS