1603.1.4 Wind design data. The following information related to wind loads shall be shown,
regardless of whether wind loads govern the design of the lateral force-resisting system of the
structure:
1. Basic design wind speed, V, miles per hour and allowable stress design wind speed, Vāād,
as determined in accordance with Section 1609.3.1.
2. Risk category.
3. Wind exposure. Applicable wind direction if more than one wind exposure is utilized.
4. Applicable internal pressure coefficient.
125
5. Design wind pressures to be used for exterior component and cladding materials not
specifically designed by the registered design professional responsible for the design
of the structure, psf (kN/m2), shall be coordinated and approved by the designer of