Regl. 9049, art. 107-4.1
and Section 6.1 Table 10.
Length: 7,430 wordsOfficial source
Cite as Reglamento Núm. 9049, Art. 107-4.1
[BS]POSITIVE ROOF DRAINAGE. The drainage condition in which consideration has been
made for all loading deflections of the roof deck, and additional slope has been provided to ensure
drainage of the roof within 48 hours of precipitation.
[BEJPOWER-ASSISTED DOOR. Swinging door which opens by reduced pushing or pulling
force on the door-operating hardware. The door closes automatically after the pushing or pulling
force is released and functions with decreased forces. See "Low-energy power-operated door" and
"Power-operated door."
[BE]POWER-OPERATED DOOR. Swinging, sliding, or folding door which opens
automatically when approached by a pedestrian or opens automatically upon an action by a
pedestrian. The door closes automatically and includes provisions such as presence sensors to
prevent entrapment. See "Low energy power-operated door" and "Power-assisted door."
96
[BS]PREFABRICATED WOOD I-JOIST. Structural member manufactured using sawn or
structural composite lumber flanges and wood structural panel webs bonded together with exterior
exposure adhesives, which forms an "I" cross-sectional shape.
[BS]PRESTRESSED MASONRY. Masonry in which internal stresses have been introduced to
counteract potential tensile stresses in masonry resulting from applied loads.
[BG]PRIMARY STRUCTURAL FRAME. The primary structural frame shall include all of the
following structural members:
1. The columns.
2. Structural members having direct connections to the columns, including girders, beams,
trusses and spandrels.
3. Members of the floor construction and roof construction having direct connections to
the columns.
4. Bracing members that are essential to the vertical stability of the primary structural frame
under gravity loading shall be considered part of the primary structural frame whether
or not the bracing member carries gravity loads.
[BG]PRIVATE GARAGE. A building or portion of a building in which motor vehicles used by
the owner or tenants of the building or buildings on the premises are stored or kept, without
provisions for repairing or servicing such vehicles for profit.
[BG]PROSCENIUM WALL. The wall that separates the stage from the auditorium or assembly
seating area.
PSYCHIATRIC HOSPITALS. See "Hospitals."
[BE]PUBLIC ENTRANCE. An entrance that is not a service entrance or a restricted entrance.
[A]PUBLIC WAY. A street, alley or other parcel of land open to the outside air leading to a street,
that has been deeded, dedicated or otherwise permanently appropriated to the public for public use
and which has a clear width and height of not less than 10 feet (3048 mm).
[BE]PUBLIC-USE AREAS. Interior or exterior rooms or spaces that are made available to the
general public.
(PRPB) PUERTO RICO PLANNING BOARD. Government Agency created by ACT No. 75
of June 1975 as amended, hereinafter PRPB. In addition, it is the State Agency Coordinator of
the National Flood Insurance Program.
[F]PYROPHORIC. A chemical with an auto-ignition temperature in air, at or below a
temperature of 130°F (54.4°C).
97
[F]PYROTECHNIC COMPOSITION. A chemical mixture that produces visible light displays
or sounds through a self-propagating, heat-releasing chemical reaction which is initiated by
ignition.
[BF]RADIANT BARRIER. A material having a low-emittance surface of 0.1 or less installed in
building assemblies.
[BE]RAMP. A walking surface that has a running slope steeper than one unit vertical in 20 units
horizontal (5-percent slope).
RAMP, EXIT ACCESS. See "Exit access ramp."
RAMP, EXTERIOR EXIT. See "Exterior exit ramp."
RAMP, INTERIOR EXIT. See "Interior exit ramp."
[BG]RAMP-ACCESS OPEN PARKING GARAGES. Open parking garages employing a
series of continuously rising floors or a series of interconnecting ramps between floors permitting
the movement of vehicles under their own power from and to the street level.
[A]RECORD DRAWINGS. Drawings ("as builts") that document the location of all devices,
appliances, wiring sequences, wiring methods and connections of the components of a fire alarm
system as installed.
[BF]REFLECTIVE PLASTIC CORE INSULATION. An insulation material packaged in rolls,
that is less than 1/2 inch (12.7 mm) thick, with not less than one exterior low-emittance surface
(0.1 or less) and a core material containing voids or cells.
[AJREGISTERED DESIGN PROFESSIONAL An individual who is licensed to practice the
profession of architect or engineer as defined by the provisions of the Act No. 173 of August 12,
1988, as amended, and according to with the provisions of Act No. 135 of June 15, 1967, as
amended, (Certification Law); engaged by the owner to prepare the construction documents, make
application to the building official and obtain the required permit.
[AJREGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. A registered
design professional engaged by the owner or the owner's authorized agent to review and
coordinate certain aspects of the project, as determined by the building official, for compatibility
with the design of the building or structure, including submittal documents prepared by others,
deferred submittal documents and phased submittal documents.
[BG]RELIGIOUS WORSHIP, PLACE OF. A building or portion thereof intended for the
performance of religious services.
[AJRELOCATABLE BUILDING. A partially or completely assembled building constructed and
designed to be reused multiple times and transported to different building sites.
98
[A]REPAIR. The reconstruction, replacement or renewal of any part of an existing building for
the purpose of its maintenance or to correct damage.
[BG]REPAIR GARAGE. A building, structure or portion thereof used for servicing or repairing
motor vehicles.
[BS]REROOFING. The process of recovering or replacing an existing roof covering. See "Roof
recover" and "Roof replacement."
[BG]RESIDENTIAL AIRCRAFT HANGAR. An accessory building less than 2,000 square feet
(186 m2) and 20 feet (6096 mm) in building height constructed on a one- or two-family property
where aircraft are stored. Such use will be considered as a residential accessory use incidental to
the dwelling.
[BS]RESISTANCE FACTOR. A factor that accounts for deviations of the actual strength from
the nominal strength and the manner and consequences of failure (also called "strength reduction
factor").
[BE]RESTRICTED ENTRANCE. An entrance that is made available for common use on a
controlled basis, but not public use, and that is not a service entrance.
[BG]RETRACTABLE AWNING. A retractable awning is a cover with a frame that retracts
against a building or other structure to which it is entirely supported.
[BS]RISK CATEGORY. A categorization of buildings and other structures for determination of
flood, wind, snow, ice and earthquake loads based on the risk associated with unacceptable
performance.
[BSJRISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND
MOTION RESPONSE ACCELERATIONS. The most severe earthquake effects considered by
this code, determined for the orientation that results in the largest maximum response to horizontal
ground motions and with adjustment for targeted risk.
[BS]ROOF ASSEMBLY (For application to Chapter 15 only). A system designed to provide
weather protection and resistance to design loads. The system consists of a roof covering and roof
deck or a single component serving as both the roof covering and the roof deck. A roof assembly
can include an underlayment, a thermal barrier, insulation or a vapor retarder.
[BS]ROOF COATING. A fluid-applied, adhered coating used for roof maintenance or roof
repair, or as a component of a roof covering system or roof assembly.
[BS]ROOF COVERING. The covering applied to the roof deck for weather resistance, fire
classification or appearance.
ROOF COVERING SYSTEM. See "Roof assembly."
99
[BS]ROOF DECK. The flat or sloped surface constructed on top of the exterior walls of a building
or other supports for the purpose of enclosing the story below, or sheltering an area, to protect it
from the elements, not including its supporting members or vertical supports.
ROOF DRAINAGE, POSITIVE. See "Positive roof drainage."
[BS]ROOF RECOVER. The process of installing an additional roof covering over a prepared
existing roof covering without removing the existing roof covering.
[BS]ROOF REPAIR. Reconstruction or renewal of any part of an existing roof for the purposes
of its maintenance.
[BS]ROOF REPLACEMENT. The process of removing the existing roof covering, repairing
any damaged substrate and installing a new roof covering.
[BG]ROOF VENTILATION. The natural or mechanical process of supplying conditioned or
unconditioned air to, or removing such air from, attics, cathedral ceilings or other enclosed spaces
over which a roof assembly is installed.
[BG]ROOFTOP STRUCTURE. A structure erected on top of the roof deck or on top of any part
of a building.
[BS]RUNNING BOND. The placement of masonry units such that head joints in successive
courses are horizontally offset at least one-quarter the unit length.
[BG]SALLYPORT. A security vestibule with two or more doors or gates where the intended
purpose is to prevent continuous and unobstructed passage by allowing the release of only one
door or gate at a time.
[BE]SCISSOR STAIRWAY. Two interlocking stairways providing two separate paths of egress
located within one exit enclosure.
[BS]SCUPPER. An opening in a wall or parapet that allows water to drain from a roof.
[BG]SECONDARY MEMBERS. The following structural members shall be considered
secondary members and not part of the primary structural frame:
1. Structural members not having direct connections to the columns.
2. Members of the floor construction and roof construction not having direct connections
to the columns.
3. Bracing members other than those that are part of the primary structural frame.
[BS]SEISMIC DESIGN CATEGORY. A classification assigned to a structure based on its risk
category and the severity of the design earthquake ground motion at the site.
100
[BS]SEISMIC FORCE-RESISTING SYSTEM. That part of the structural system that has been
considered in the design to provide the required resistance to the prescribed seismic forces.
[BF]SELF-CLOSING. As applied to a fire door or other opening protective, means equipped
with a device that will ensure closing after having been opened.
[BE]SELF-LUMINOUS. Illuminated by a self-contained power source, other than batteries, and
operated independently of external power sources.
SELF-PRESERVATION, INCAPABLE OF. See "Incapable of self-preservation."
[BG]SELF-SERVICE STORAGE FACILITY. Real property designed and used for the purpose
of renting or leasing individual storage spaces to customers for the purpose of storing and removing
personal property on a self-service basis.
[F]SERVICE CORRIDOR. A fully enclosed passage used for transporting HPM and purposes
other than required means of egress.
[BE]SERVICE ENTRANCE. An entrance intended primarily for delivery of goods or services.
[BF]SHAFT. An enclosed space extending through one or more stories of a building, connecting
vertical openings in successive floors, or floors and roof.
[BF]SHAFT ENCLOSURE. The walls or construction forming the boundaries of a shaft.
[BS]SHALLOW FOUNDATION. A shallow foundation is an individual or strip footing, a mat
foundation, a slab-on-grade foundation or a similar foundation element.
[BS]SHEAR WALL (for Chapter 23). A wall designed to resist lateral forces parallel to the
plane of a wall.
Shear wall, perforated. A wood structural panel sheathed wall with openings, that has not
been specifically designed and detailed for force transfer around openings.
Shear wall segment, perforated. A section of shear wall with full-height sheathing that
meets the height-to-width ratio limits of Section 4.3.4 of AWC SDPWS.
[BS]SHINGLE FASHION. A method of installing roof or wall coverings, water-resistive
barriers, flashing or other building components such that upper layers of material are placed
overlapping lower layers of material to provide for drainage via gravity and moisture control.
[BS]SINGLE-PLY MEMBRANE. A roofing membrane that is field applied using one layer of
membrane material (either homogeneous or composite) rather than multiple layers.
101
[FJSINGLE-STATION SMOKE ALARM. An assembly incorporating the detector, the control
equipment and the alarm-sounding device in one unit, operated from a power supply either in the
unit or obtained at the point of installation.
[BG]SITE. A parcel of land bounded by a lot line or a designated portion of a public right-of-way.
[BS]SITE CLASS. A classification assigned to a site based on the types of soils present and their
engineering properties as defined in Section 1613.3.2.
[BS]SITE COEFFICIENTS. The values of Fa and Fv indicated in Tables 1613.3.3(1) and
1613.3.3(2), respectively.
[BG]SITE-FABRICATED STRETCH SYSTEM. A system, fabricated on site and intended for
acoustical, tackable or aesthetic purposes, that is composed of three elements:
1. A frame (constructed of plastic, wood, metal or other material) used to hold fabric in
place.
2. A core material (infill, with the correct properties for the application).
3. An outside layer, composed of a textile, fabric or vinyl, that is stretched taut and held in
place by tension or mechanical fasteners via the frame.
[BS]SKYLIGHT, UNIT. A factory-assembled, glazed fenestration unit, containing one panel of
glazing material that allows for natural lighting through an opening in the roof assembly while
preserving the weather-resistant barrier of the roof.
[BS]SKYLIGHTS AND SLOPED GLAZING. Glass or other transparent or translucent glazing
material installed at a slope of 15 degrees (0.26 rad) or more from vertical. Unit skylights, tubular
daylighting devices, glazing materials, solariums, sunrooms, roofs and sloped walls are included
in this definition.
[A]SLEEPING UNIT. A single unit that provides rooms or spaces for one or more persons,
includes permanent provisions for sleeping and can include provisions for living, eating and either
sanitation or kitchen facilities but not both. Such rooms and spaces that are also part of a dwelling
unit are not sleeping units.
[F]SMOKE ALARM. A single- or multiple-station alarm responsive to smoke. See "Multiplestation smoke alarm" and "Single-station smoke alarm."
[BF]SMOKE BARRIER. A continuous membrane, either vertical or horizontal, such as a wall,
floor or ceiling assembly, that is designed and constructed to restrict the movement of smoke.
[BG]SMOKE COMPARTMENT. A space within a building enclosed by smoke barriers on all
sides, including the top and bottom.
102
[BF]SMOKE DAMPER. A listed device installed in ducts and air transfer openings designed to
resist the passage of smoke. The device is installed to operate automatically, controlled by a smoke
detection system, and where required, is capable of being positioned from a fire command center.
[F]SMOKE DETECTOR. A listed device that senses visible or invisible particles of combustion.
[BF]SMOKE PARTITION. A wall assembly that extends from the top of the foundation or floor
below to the underside of the floor or roof sheathing, deck or slab above or to the underside of the
ceiling above where the ceiling membrane is constructed to limit the transfer of smoke.
[BF]SMOKE-DEVELOPED INDEX. A comparative measure, expressed as a dimensionless
number, derived from measurements of smoke obscuration versus time for a material tested in
accordance with ASTM E84.
[BFJSMOKEPROOF ENCLOSURE. An exit stairway or ramp designed and constructed so that
the movement of the products of combustion produced by a fire occurring in any part of the
building into the enclosure is limited.
[BE]SMOKE-PROTECTED ASSEMBLY SEATING. Seating served by means of egress that
is not subject to smoke accumulation within or under a structure for a specified design time by
means of passive design or by mechanical ventilation.
[BG]SOFT CONTAINED PLAY EQUIPMENT STRUCTURE. A children's play structure
containing one or more components where the user enters a play environment that utilizes pliable
materials.
[F]SOLID. A material that has a melting point, decomposes or sublimes at a temperature greater
than 68°F (20°C).
[BG]SPECIAL AMUSEMENT BUILDING. A special amusement building is any temporary or
permanent building or portion thereof that is occupied for amusement, entertainment or
educational purposes and that contains a device or system that conveys passengers or provides a
walkway along, around or over a course in any direction so arranged that the means of egress path
is not readily apparent due to visual or audio distractions or is intentionally confounded or is not
readily available because of the nature of the attraction or mode of conveyance through the
building or structure.
[BS]SPECIAL FLOOD HAZARD AREA. The land area subject to flood hazards and shown on
a Flood Insurance Rate Map or other flood hazard map as Zone A, AE, A1-30, A99, AR, AO, AH,
V, VO, VE or V1-30.
[BS]SPECIAL INSPECTION. Inspection of construction requiring the expertise of an approved
special inspector in order to ensure compliance with this code and the approved construction
documents.
103
Continuous special inspection. Special inspection by the special inspector who is present
continuously when and where the work to be inspected is being performed.
Periodic special inspection. Special inspection by the special inspector who is
intermittently present where the work to be inspected has been or is being performed.
[BS]SPECIAL INSPECTOR. A qualified person employed or retained by an approved agency
and approved by the building official as having the competence necessary to inspect a particular
type of construction requiring special inspection.
[BS]SPECIAL STRUCTURAL WALL. See Section 1905.1.1.
[BS]SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, f'm. Minimum compressive
strength, expressed as force per unit of net cross-sectional area, required of the masonry used in
construction by the approved construction documents, and upon which the project design is based.
Whenever the quantity f'm is under the radical sign, the square root of numerical value only is
intended and the result has units of pounds per square inch (psi) (MPa).
[BF]SPLICE. The result of a factory and/or field method of joining or connecting two or more
lengths of a fire-resistant joint system into a continuous entity.
SPORT ACTIVITY, AREA OF. See "Area of sport activity."
[F]SPRAY ROOM. A room designed to accommodate spraying operations.
[BF]SPRAYED FIRE-RESISTANT MATERIALS. Cementitious or fibrous materials that are
sprayed to provide fire-resistant protection of the substrates.
[BG]STAGE. A space within a building utilized for entertainment or presentations, which
includes overhead hanging curtains, drops, scenery or stage effects other than lighting and sound.
[BE]STAIR. A change in elevation, consisting of one or more risers.
[BE]STAIRWAY. One or more flights of stairs, either exterior or interior, with the necessary
landings and platforms connecting them, to form a continuous and uninterrupted passage from one
level to another.
STAIRWAY, EXIT ACCESS. See "Exit access stairway."
STAIRWAY, EXTERIOR EXIT. See "Exterior exit stairway."
STAIRWAY, INTERIOR EXIT. See "Interior exit stairway."
STAIRWAY, SCISSOR. See "Scissor stairway."
104
[BE]STAIRWAY, SPIRAL. A stairway having a closed circular form in its plan view with
uniform section-shaped treads attached to and radiating from a minimum-diameter supporting
column.
[F]STANDBY POWER SYSTEM. A source of automatic electric power of a required capacity
and duration to operate required building, hazardous materials or ventilation systems in the event
of a failure of the primary power. Standby power systems are required for electrical loads where
interruption of the primary power could create hazards or hamper rescue or fire-fighting
operations.
[F]STANDPIPE, TYPES OF. Standpipe types are as follows:
Automatic dry. A dry standpipe system, normally filled with pressurized air, that is
arranged through the use of a device, such as dry pipe valve, to admit water into the system
piping automatically upon the opening of a hose valve. The water supply for an automatic
dry standpipe system shall be capable of supplying the system demand.
Automatic wet. A wet standpipe system that has a water supply that is capable of supplying
the system demand automatically.
Manual dry. A dry standpipe system that does not have a permanent water supply attached
to the system. Manual dry standpipe systems require water from a fire department pumper
to be pumped into the system through the fire department connection in order to meet the
system demand.
Manual wet. A wet standpipe system connected to a water supply for the purpose of
maintaining water within the system but does not have a water supply capable of delivering
the system demand attached to the system. Manual wet standpipe systems require water
from a fire department pumper (or the like) to be pumped into the system in order to meet
the system demand.
Semiautomatic dry. A dry standpipe system that is arranged through the use of a device,
such as a deluge valve, to admit water into the system piping upon activation of a remote
control device located at a hose connection. A remote control activation device shall be
provided at each hose connection. The water supply for a semiautomatic dry standpipe
system shall be capable of supplying the system demand.
[F]STANDPIPE SYSTEM, CLASSES OF. Standpipe classes are as follows:
Class I system. A system providing 21/2-inch (64 mm) hose connections to supply water
for use by fire departments and those trained in handling heavy fire streams.
Class II system. A system providing 11/2-inch (38 mm) hose stations to supply water for
use primarily by the building occupants or by the fire department during initial response.
105
Class III system. A system providing 11/2-inch (38 mm) hose stations to supply water for
use by building occupants and 21/2-inch (64 mm) hose connections to supply a larger
volume of water for use by fire departments and those trained in handling heavy fire
streams.
[BS]START OF CONSTRUCTION. The date of permit issuance for new construction and
substantial improvements to existing structures, provided the actual start of construction, repair,
reconstruction, rehabilitation, addition, placement or other improvement is within 180 days after
the date of issuance. The actual start of construction means the first placement of permanent
construction of a building (including a manufactured home) on a site, such as the pouring of a slab
or footings, installation of pilings or construction of columns. Permanent construction does not
include land preparation (such as clearing, excavation, grading or filling), the installation of streets
or walkways, excavation for a basement, footings, piers or foundations, the erection of temporary
forms or the installation of accessory buildings such as garages or sheds not occupied as dwelling
units or not part of the main building. For a substantial improvement, the actual "start of
construction" means the first alteration of any wall, ceiling, floor or other structural part of a
building, whether or not that alteration affects the external dimensions of the building.
[BS]STEEL CONSTRUCTION, COLD-FORMED. That type of construction made up entirely
or in part of steel structural members cold formed to shape from sheet or strip steel such as roof
deck, floor and wall panels, studs, floor joists, roof joists and other structural elements.
[BS]STEEL ELEMENT, STRUCTURAL. Any steel structural member of a building or
structure consisting of rolled shapes, pipe, hollow structural sections, plates, bars, sheets, rods or
steel castings other than cold-formed steel or steel joist members.
[BS]STEEL JOIST. Any steel structural member of a building or structure made of hot-rolled or
cold-formed solid or open-web sections, or riveted or welded bars, strip or sheet steel members, or
slotted and expanded, or otherwise deformed rolled sections.
[BF]STEEP SLOPE. A roof slope greater than two units vertical in 12 units horizontal (17-
percent slope).
[BS]STONE MASONRY. Masonry composed of field, quarried or cast stone units bonded by
mortar.
[F]STORAGE, HAZARDOUS MATERIALS. The keeping, retention or leaving of hazardous
materials in closed containers, tanks, cylinders, or similar vessels; or vessels supplying operations
through closed connections to the vessel.
[BS]STORAGE RACKS. Cold-formed or hot-rolled steel structural members which are formed
into steel storage racks, including pallet storage racks, movable-shelf racks, rack-supported
systems, automated storage and retrieval systems (stacker racks), push-back racks, pallet-flow
racks, case-flow racks, pick modules and rack-supported platforms. Other types of racks, such as
drive-in or drive-through racks, cantilever racks, portable racks or racks made of materials other
than steel, are not considered storage racks for the purpose of this code.
106
[BG]STORM SHELTER. A building, structure or portions thereof, constructed in accordance
with ICC 500 and designated for use during a severe wind storm event, such as a hurricane or
tornado.
Community storm shelter. A storm shelter not defined as a "Residential storm shelter."
Residential storm shelter. A storm shelter serving occupants of dwelling units and having
an occupant load not exceeding 16 persons.
[BG]STORY. That portion of a building included between the upper surface of a floor and the
upper surface of the floor or roof next above (see "Basement," "Building height, "Grade plane"
and "Mezzanine"). A story is measured as the vertical distance from top to top of two successive
tiers of beams or finished floor surfaces and, for the topmost story, from the top of the floor finish
to the top of the ceiling joists or, where there is not a ceiling, to the top of the roof rafters.
[BG]STORY ABOVE GRADE PLANE. Any story having its finished floor surface entirely
above grade plane, or in which the finished surface of the floor next above is:
1. More than 6 feet (1829 mm) above grade plane; or
2. More than 12 feet (3658 mm) above the finished ground level at any point.
[BS]STRENGTH (For Chapter 21).
Design strength. Nominal strength multiplied by a strength reduction factor.
Nominal strength. Strength of a member or cross section calculated in accordance with
these provisions before application of any strength-reduction factors.
Required strength. Strength of a member or cross section required to resist factored loads.
[BS]STRENGTH (for Chapter 16).
Nominal strength. The capacity of a structure or member to resist the effects of loads, as
determined by computations using specified material strengths and dimensions and
equations derived from accepted principles of structural mechanics or by field tests or
laboratory tests of scaled models, allowing for modeling effects and differences between
laboratory and field conditions.
Required strength. Strength of a member, cross section or connection required to resist
factored loads or related internal moments and forces in such combinations as stipulated
by these provisions.
Strength design. A method of proportioning structural members such that the computed
forces produced in the members by factored loads do not exceed the member design
strength
107
[also called "load and resistance factor design" (LRFD)]. The term "strength design" is
used in the design of concrete and masonry structural elements.
[BS]STRUCTURAL COMPOSITE LUMBER. Structural member manufactured using wood
elements bonded together with exterior adhesives. Examples of structural composite lumber are:
Laminated strand lumber (LSL). A composite of wood strand elements with wood fibers
primarily oriented along the length of the member, where the least dimension of the wood
strand elements is 0.10 inch (2.54 mm) or less and their average lengths not less than 150
times the least dimension of the wood strand elements.
Laminated veneer lumber (LVL). A composite of wood veneer sheet elements with wood
fibers primarily oriented along the length of the member, where the veneer element
thicknesses are 0.25 inches (6.4 mm) or less.
Oriented strand lumber (OSL). A composite of wood strand elements with wood fibers
primarily oriented along the length of the member, where the least dimension of the wood
strand elements is 0.10 inches (2.54 mm) or less and their average lengths not less than 75
times and less than 150 times the least dimension of the strand elements.
Parallel strand lumber (PSL). A composite of wood strand elements with wood fibers
primarily oriented along the length of the member where the least dimension of the wood
strand elements is 0.25 inches (6.4 mm) or less and their average lengths not less than 300
times the least dimension of the wood strand elements.
[BS]STRUCTURAL GLUED-LAMINATED TIMBER. An engineered, stress-rated product of
a timber laminating plant, comprised of assemblies of specially selected and prepared wood
laminations in which the grain of all laminations is approximately parallel longitudinally and the
laminations are bonded with adhesives.
[BS]STRUCTURAL OBSERVATION. The visual observation of the structural system by a
registered design professional for general conformance to the approved construction documents.
[A]STRUCTURE. That which is built or constructed.
[BS]SUBSTANTIAL DAMAGE. Damage of any origin sustained by a structure whereby the
cost of restoring the structure to its before-damaged condition would equal or exceed 50 percent
of the market value of the structure before the damage occurred.
[BS]SUBSTANTIAL IMPROVEMENT. Any repair, reconstruction, rehabilitation, alteration,
addition or other improvement of a building or structure, the cost of which equals or exceeds 50
percent of the market value of the structure before the improvement or repair is started. If the
structure has sustained substantial damage, any repairs are considered substantial improvement
regardless of the actual repair work performed. The term does not, however, include either:
108
1. Any project for improvement of a building required to correct existing health, sanitary
or safety code violations identified by the building official and that are the minimum
necessary to assure safe living conditions.
2. Any alteration of a historic structure provided that the alteration will not preclude the
structure's continued designation as a historic structure.
[BG]SUNROOM. A one-story structure attached to a building with a glazing area in excess of 40
percent of the gross area of the structure's exterior walls and roof.
[F]SUPERVISING STATION. A facility that receives signals and at which personnel are in
attendance at all times to respond to these signals.
[F]SUPERVISORY SERVICE. The service required to monitor performance of guard tours and
the operative condition of fixed suppression systems or other systems for the protection of life and
property.
[F]SUPERVISORY SIGNAL. A signal indicating the need of action in connection with the
supervision of guard tours, the fire suppression systems or equipment or the maintenance features
of related systems.
[F]SUPERVISORY SIGNAL-INITIATING DEVICE. An initiation device, such as a valve
supervisory switch, water-level indicator or low-air pressure switch on a dry-pipe sprinkler system,
whose change of state signals an off-normal condition and its restoration to normal of a fire
protection or life safety system, or a need for action in connection with guard tours, fire suppression
systems or equipment or maintenance features of related systems.
[BS]SUSCEPTIBLE BAY. A roof or portion thereof with either of the following:
1. A slope less than 1/4-inch per foot (0.0208 rad).
2. On which water is impounded, in whole or in part, and the secondary drainage system is
functional but the primary drainage system is blocked. A roof surface with a slope of 1/4-
inch per foot (0.0208 rad) or greater towards points of free drainage is not a susceptible
bay.
[BG]SWIMMING POOL. Any structure intended for swimming, recreational bathing or wading
that contains water over 24 inches (610 mm) deep. This includes in-ground, above-ground and onground pools; hot tubs; spas and fixed-in-place wading pools.
[BF]T RATING. The time period that the penetration firestop system, including the penetrating
item, limits the maximum temperature rise to 325°F (163°C) above its initial temperature through
the penetration on the nonfire side when tested in accordance with ASTM E814 or UL 1479.
[BG]TECHNICAL PRODUCTION AREA. Open elevated areas or spaces intended for
entertainment technicians to walk on and occupy for servicing and operating entertainment
technology systems and equipment. Galleries, including fly and lighting galleries, gridirons,
catwalks, and similar areas are designed for these purposes.
109
[BG]TENSILE MEMBRANE STRUCTURE. A membrane structure having a shape that is
determined by tension in the membrane and the geometry of the support structure. Typically, the
structure consists of both flexible elements (e.g., membrane and cables), nonflexible elements
(e.g., struts, masts, beams and arches) and the anchorage (e.g., supports and foundations). This
includes frame-supported tensile membrane structures.
[F]TENT. A structure, enclosure, umbrella structure or shelter, with or without sidewalls or drops,
constructed of fabric or pliable material supported in any manner except by air or the contents it
protects (see "Umbrella structure").
[BG]THERMAL ISOLATION. A separation of conditioned spaces, between a sunroom and a
dwelling unit, consisting of existing or new walls, doors or windows.
[BFJTHERMOPLASTIC MATERIAL. A plastic material that is capable of being repeatedly
softened by increase of temperature and hardened by decrease of temperature.
[BFJTHERMOSETTING MATERIAL. A plastic material that is capable of being changed into
a substantially nonreformable product when cured.
[BF]THROUGH PENETRATION. A breach in both sides of a floor, floor-ceiling and wall
assembly to accommodate an item passing through the breaches.
[BFJTHROUGH-PENETRATION FIRESTOP SYSTEM. An assemblage consisting of a fireresistance-rated floor, floor-ceiling, or wall assembly, one or more penetrating items passing
through the breaches in both sides of the assembly and the materials or devices, or both, installed
to resist the spread of fire through the assembly for a prescribed period of time.
[BS]TIE, WALL. Metal connector that connects wythes of masonry walls together.
[BS]TIE-DOWN (HOLD-DOWN). A device used to resist uplift of the chords of shear walls.
[BS]TILE, STRUCTURAL CLAY. A hollow masonry unit composed of burned clay, shale, fire
clay or mixture thereof, and having parallel cells.
[F]TIRES, BULK STORAGE OF. Storage of tires where the area available for storage exceeds
20,000 cubic feet (566 m3).
[AJTOWNHOUSE. A single-family dwelling unit constructed in a group of three or more
attached units in which each unit extends from the foundation to roof and with open space on at
least two sides.
[F]TOXIC. A chemical falling within any of the following categories:
110
1. A chemical that has a median lethal dose (LD50) of more than 50 milligrams per
kilogram, but not more than 500 milligrams per kilogram of body weight when
administered orally to albino rats weighing between 200 and 300 grams each.
2. A chemical that has a median lethal dose (LD50) of more than 200 milligrams per
kilogram, but not more than 1,000 milligrams per kilogram of body weight when
administered by continuous contact for 24 hours (or less if death occurs within 24 hours)
with the bare skin of albino rabbits weighing between 2 and 3 kilograms each.
3. A chemical that has a median lethal concentration (LC50) in air of more than 200 parts
per million, but not more than 2,000 parts per million by volume of gas or vapor, or
more than 2 milligrams per liter but not more than 20 milligrams per liter of mist, fume
or dust, when administered by continuous inhalation for 1 hour (or less if death occurs
within 1 hour) to albino rats weighing between 200 and 300 grams each.
[BG]TRANSIENT. Occupancy of a dwelling unit or sleeping unit for not more than 30 days.
[BG]TRANSIENT AIRCRAFT. Aircraft based at another location and that is at the transient
location for not more than 90 days.
[BS]TREATED WOOD. Wood products that are conditioned to enhance fire-retardant or
preservative properties.
Fire-retardant-treated wood. Wood products that, when impregnated with chemicals by
a pressure process or other means during manufacture, exhibit reduced surface-burning
characteristics and resist propagation of fire.
Preservative-treated wood. Wood products that, conditioned with chemicals by a
pressure process or other means, exhibit reduced susceptibility to damage by fungi, insects
or marine borers.
[BF]TRIM. Picture molds, chair rails, baseboards, handrails, door and window frames and similar
decorative or protective materials used in fixed applications.
[F]TROUBLE SIGNAL. A signal initiated by the fire alarm system or device indicative of a fault
in a monitored circuit or component.
[BS]TSUNAMI DESIGN GEODATABASE. The ASCE database (version 2016-1.0) of
Tsunami Design Zone maps and associated design data for the states of Alaska, California, Hawaii,
Oregon and Washington.
[BS]TSUNAMI DESIGN ZONE. An area identified on the Tsunami Design Zone map between
the shoreline and the inundation limit, within which certain structures designated in Chapter 16
are designed for or protected from inundation.
[BS]TUBULAR DAYLIGHTING DEVICE (TDD). A non-operable fenestration unit primarily
designed to transmit daylight from a roof surface to an interior ceiling via a tubular conduit. The
basic unit consists of an exterior glazed weathering surface, a light-transmitting tube with a
111
reflective interior surface, and an interior-sealing device such as a translucent ceiling panel. The
unit can be factory assembled, or field-assembled from a manufactured kit.
24-HOUR BASIS. See "24-hour basis" located preceding "AAC masonry."
[BE]TYPE A UNIT. A dwelling unit or sleeping unit designed and constructed for accessibility
in accordance with this code and the provisions for Type A units in ICC A117.1.
[BE]TYPE B UNIT. A dwelling unit or sleeping unit designed and constructed for accessibility
in accordance with this code and the provisions for Type B units in ICC A117.1, consistent with
the design and construction requirements of the federal Fair Housing Act.
[F]UMBRELLA STRUCTURE. A structure, enclosure or shelter with or without sidewalls or
drops, constructed of fabric or pliable material supported by a central pole or poles (see "Tent").
[BSJUNDERLAYMENT One or more layers of a material that is applied to a steep-slope roof
covering deck under the roof covering and resists liquid water that penetrates the roof covering.
UNIT SKYLIGHT. See "Skylight, unit."
[F]UNSTABLE (REACTIVE) MATERIAL. A material, other than an explosive, which in the
pure state or as commercially produced, will vigorously polymerize, decompose, condense or
become self-reactive and undergo other violent chemical changes, including explosion, when
exposed to heat, friction or shock, or in the absence of an inhibitor, or in the presence of
contaminants, or in contact with incompatible materials. Unstable (reactive) materials are
subdivided as follows:
Class 4. Materials that in themselves are readily capable of detonation or explosive
decomposition or explosive reaction at normal temperatures and pressures. This class
includes materials that are sensitive to mechanical or localized thermal shock at normal
temperatures and pressures.
Class 3. Materials that in themselves are capable of detonation or of explosive
decomposition or explosive reaction but which require a strong initiating source or which
must be heated under confinement before initiation. This class includes materials that are
sensitive to thermal or mechanical shock at elevated temperatures and pressures.
Class 2. Materials that in themselves are normally unstable and readily undergo violent
chemical change but do not detonate. This class includes materials that can undergo
chemical change with rapid release of energy at normal temperatures and pressures, and
that can undergo violent chemical change at elevated temperatures and pressures.
Class 1. Materials that in themselves are normally stable but which can become unstable
at elevated temperatures and pressure.
[F]USE (MATERIAL). Placing a material into action, including solids, liquids and gases.
112
[BF]VAPOR PERMEABLE. The property of having a moisture vapor permeance rating of 5
perms (2.9 X 10-10 kg/ Pa X S X m2) or greater, when tested in accordance with the desiccant
method using Procedure A of ASTM E96. A vapor permeable material permits the passage of
moisture vapor.
[BF]VAPOR RETARDER CLASS. A measure of a material or assembly's ability to limit the
amount of moisture that passes through that material or assembly. Vapor retarder class shall be
defined using the desiccant method with Procedure A of ASTM E96 as follows:
Class I: 0.1 perm or less.
Class II: 0.1 < perm ≤ 1.0 perm.
Class III: 1.0 < perm ≤ 10 perm.
[BS]VEGETATIVE ROOF. An assembly of interacting components designed to waterproof a
building's top surface that includes, by design, vegetation and related landscape elements.
[BS]VEHICLE BARRIER. A component or a system of components, near open sides or walls
of garage floors or ramps that act as a restraint for vehicles.
[BG]VEHICULAR GATE. A gate that is intended for use at a vehicular entrance or exit to a
facility, building or portion thereof, and that is not intended for use by pedestrian traffic.
[BF]VENEER. A facing attached to a wall for the purpose of providing ornamentation, protection
or insulation, but not counted as adding strength to the wall.
[M]VENTILATION. The natural or mechanical process of supplying conditioned or
unconditioned air to, or removing such air from, any space.
[BF]VINYL SIDING. A shaped material, made principally from rigid polyvinyl chloride (PVC),
that is used as an exterior wall covering.
[F]VISIBLE ALARM NOTIFICATION APPLIANCE. A notification appliance that alerts by
the sense of sight.
[BG]WALKWAY, PEDESTRIAN. A walkway used exclusively as a pedestrian trafficway.
[BS]WALL (for Chapter 21). A vertical element with a horizontal length-to-thickness ratio
greater than three, used to enclose space.
Cavity wall. A wall built of masonry units or of concrete, or a combination of these
materials, arranged to provide an airspace within the wall, and in which the inner and outer
parts of the wall are tied together with metal ties.
113
Dry-stacked, surface-bonded wall. A wall built of concrete masonry units where the units
are stacked dry, without mortar on the bed or head joints, and where both sides of the wall
are coated with a surface-bonding mortar.
Parapet wall. The part of any wall entirely above the roof line.
[BS]WALL, LOAD-BEARING. Any wall meeting either of the following classifications:
1. Any metal or wood stud wall that supports more than 100 pounds per linear foot (1459
N/m) of vertical load in addition to its own weight.
2. Any masonry or concrete wall that supports more than 200 pounds per linear foot (2919
N/m) of vertical load in addition to its own weight.
[BS]WALL, NONLOAD-BEARING. Any wall that is not a load-bearing wall.
[FJWATER-REACTIVE MATERIAL. A material that explodes; violently reacts; produces
flammable, toxic or other hazardous gases; or evolves enough heat to cause autoignition or ignition
of combustibles upon exposure to water or moisture. Water-reactive materials are subdivided as
follows:
Class 3. Materials that react explosively with water without requiring heat or confinement.
Class 2. Materials that react violently with water or have the ability to boil water. Materials
that produce flammable, toxic or other hazardous gases or evolve enough heat to cause
autoignition or ignition of combustibles upon exposure to water or moisture.
Class 1. Materials that react with water with some release of energy, but not violently.
[BFJWATER-RESISTIVE BARRIER. A material behind an exterior wall covering that is
intended to resist liquid water that has penetrated behind the exterior covering from further
intruding into the exterior wall assembly.
[BFJWEATHER-EXPOSED SURFACES. Surfaces of walls, ceilings, floors, roofs, soffits and
similar surfaces exposed to the weather except the following:
1. Ceilings and roof soffits enclosed by walls, fascia, bulkheads or beams that extend not
less than 12 inches (305 mm) below such ceiling or roof soffits.
2. Walls or portions of walls beneath an unenclosed roof area, where located a horizontal
distance from an open exterior opening equal to not less than twice the height of the
opening.
3. Ceiling and roof soffits located a minimum horizontal distance of 10 feet (3048 mm)
from the outer edges of the ceiling or roof soffits.
[FJWET-CHEMICAL EXTINGUISHING SYSTEM. A solution of water and potassiumcarbonate-based chemical, potassium-acetate-based chemical or a combination thereof, forming
an extinguishing agent.
114
[BEJWHEELCHAIR SPACE. A space for a single wheelchair and its occupant.
[BS]WINDBORNE DEBRIS REGION. Areas within hurricane-prone regions located:
1. Within 1 mile (1.61 km) of the coastal mean high-water line where the basic design wind
speed, V, is 130 mph (58 m/s) or greater; or
2. In areas where the basic design wind speed is 140 mph (63.6 m/s) or greater. For Risk
Category II buildings and structures and Risk Category III buildings and structures, except
health care facilities, the windborne debris region shall be based on Figure 1609.3.(1). For
Risk Category IV buildings and structures and Risk Category III health care facilities, the
windborne debris region shall be based on Figure 1609.3(2).
WINDFORCE-RESISTING SYSTEM, MAIN. See "Main windforce-resisting system."
[BS]WIND SPEED, V. Basic design wind speeds.
[BS]WIND SPEED, Vasd. Allowable stress design wind speeds.
[BE]WINDER. A tread with nonparallel edges.
[BS]WIRE BACKING. Horizontal strands of tautened wire attached to surfaces of vertical
supports which, when covered with the building paper, provide a backing for cement plaster.
[F]WIRELESS PROTECTION SYSTEM. A system or a part of a system that can transmit and
receive signals without the aid of wire.
[BS]WOOD/PLASTIC COMPOSITE. A composite material made primarily from wood or
cellulose-based materials and plastic.
[BS]WOOD SHEAR PANEL. A wood floor, roof or wall component sheathed to act as a shear
wall or diaphragm.
[BS]WOOD STRUCTURAL PANEL. A panel manufactured from veneers, wood strands or
wafers or a combination of veneer and wood strands or wafers bonded together with waterproof
synthetic resins or other suitable bonding systems. Examples of wood structural panels are:
Composite panels. A wood structural panel that is comprised of wood veneer and
reconstituted wood-based material and bonded together with waterproof adhesive.
Oriented strand board (OSB). A mat-formed wood structural panel comprised of thin
rectangular wood strands arranged in cross-aligned layers with surface layers normally
arranged in the long panel direction and bonded with waterproof adhesive.
115
Plywood. A wood structural panel comprised of plies of wood veneer arranged in crossaligned layers. The plies are bonded with waterproof adhesive that cures on application of
heat and pressure.
[FJWORKSTATION. A defined space or an independent principal piece of equipment using
HPM within afabrication area where a specific function, laboratory procedure or research activity
occurs. Approved or listed hazardous materials storage cabinets, flammable liquid storage
cabinets or gas cabinets serving a workstation are included as part of the workstation. A
workstation is allowed to contain ventilation equipment, fire protection devices, detection devices,
electrical devices and other processing and scientific equipment.
[BS]WYTHE. Each continuous, vertical section of a wall, one masonry unit in thickness.
[BG]YARD. An open space, other than a court, unobstructed from the ground to the sky, except
where specifically provided by this code, on the lot on which a building is situated.
[F]ZONE. A defined area within the protected premises. A zone can define an area from which a
signal can be received, an area to which a signal can be sent or an area in which a form of control
can be executed.
[F]ZONE, NOTIFICATION. An area within a building or facility covered by notification
appliances which are activated simultaneously.
116
CHAPTER 3 - OCCUPANCY - CLASSIFICATION AND USE
No amendments
CHAPTER 4 - SPECIAL DETAILED REQUIREMENTS BASE
ON USE AND OCCUPANCY