250-RICR-120-05-12
250-RICR-120-05-12. Incinerators (version Periodic Refile, 12/31/2001 to 07/19/2007)
AIR POLLUTION CONTROL REGULATION NO. 12
INCINERATORS
Effective February 28, 1972
Last Amended August 21, 2000
2
RHODE ISLAND DEPARTMENT OF ENVIRONMENTAL MANAGEMENT
OFFICE OF AIR RESOURCES
AIR POLLUTION CONTROL REGULATION NO. 12
INCINERATORS
12 Incinerators
12.1 Definitions
As used in these regulations, the following terms shall, where the context permits,
be construed as follows:
12.1.1 "Small incinerator" means an incinerator having a capacity of less than
2000 pounds per hour operated for the thermal degradation of Types 0, l, 2
and 3 refuse.
12.1.2 "Large incinerator" means an incinerator having a capacity of 2,000 pounds
or more per hour operated for the thermal degradation of Types 0, l, 2 and 3
refuse.
12.1.3 "Pathological incinerator" means an incinerator designed for the thermal
degradation of pathological waste (Type 4 refuse).
12.1.4 "Special incinerator" means an incinerator designed for the thermal
degradation of Types 5 and 6 refuse.
12.1.5 "Sewage sludge incinerator" means an incinerator designed for the thermal
degradation of the sludge produced by municipal sewage treatment facilities.
12.1.6 "Dry sludge" means the total solids residue determined in accordance with
"224 G. Method for Solid and Semisolid Samples," Standard Methods for
the Examination of Water and Wastewater, Thirteenth Edition, American
Public Health Association, Inc., New York, New York,1971, pp. 539-41, as
amended, such that:
(a)
Evaporating dishes shall be ignited to at least 103oC rather than the
550oC specified in step 3 (a) (1);
(b)
Determination of volatile residue, step 3 (b) may be deleted.
12.1.7 "Type O refuse" means trash, consisting of a mixture of highly combustible
refuse such as paper, cardboard, cartons, wood boxes and combustible floor
sweepings, containing approximately ten percent moisture and five percent
3
incombustible solids, and having a heating value of approximately 8,500 Btu
per pound as fired, and deriving from commercial and industrial activities.
The mixtures contain up to ten percent by weight of plastic bags, coated
paper, laminated paper, treated corrugated cardboard, oily rags and plastic
or rubber scraps.
12.1.8 "Type 1 refuse" means rubbish, consisting of a mixture of combustible
refuse such as paper, cardboard, cartons, wood scraps, foliage and
combustible floor sweepings, containing approximately 25 percent moisture
and ten percent combustible solids and having a heating value of
approximately 6,500 Btu per pound as fired, and deriving from domestic,
commercial and industrial activities. The mixture contains up to 20 percent
by weight of restaurant or cafeteria refuse but contains little or no treated
paper, plastic or rubber refuse.
12.1.9 "Type 2 refuse" means refuse, consisting of an approximately even mixture
of rubbish and garbage by weight, containing up to 50 percent moisture and
approximately seven percent incombustible solids, and having a heating
value of approximately 4,300 Btu per pound as fired, and commonly
deriving from apartment and residential occupancy.
12.1.10 "Type 3 refuse" means garbage, consisting of animal and vegetable refuse
containing up to 70 percent moisture and up to five percent incombustible
solids and having a heating value of approximately 2,500 Btu per pound as
fired and deriving from restaurants, cafeterias, hotels, hospitals, markets and
like installations.
12.1.11 "Type 4 refuse" means human and animal remains, consisting of carcasses,
organs, and solid organic refuse from hospitals, laboratories, abbatoirs,
animal pounds, and similar sources and any matter or materials involving or
pertaining to disease or disease-producing organisms, including infectious
agents and helminths.
12.1.12 "Type 5 refuse" means gaseous, liquid or semiliquid by-product refuse
from industrial operations not defined as a hazardous material.
12.1.13 "Type 6 refuse" means solid by-product refuse from industrial operations
not defined as a hazardous material.
12.1.14 "Multiple chamber incinerator" means an incinerator with two or more
refractory-lined combustion chambers in series separated physically by
refractory walls, interconnected by gas passages, and employing adequate
design parameters necessary for maximum combustion of the refuse
materials.
4
12.1.15 "Single chamber flue-fed incinerator" means an incinerator with one
combustion chamber and a single flue that serves as both the charging chute
and the flue to transport products of combustion to the atmosphere.
12.1.16 "Hazardous material" means any material or combination of materials of a
solid, liquid, contained gaseous, or semisolid form that because of quantity,
concentration, or physical, chemical or other characteristics may:
(a)
cause or significantly contribute to an increase in mortality or an
increase in serious irreversible or incapacitating reversible illness; or
(b)
pose a substantial present or potential hazard to human health or the
environment.
Such materials include, but are not limited to, those that are toxic, corrosive,
flammable, irritants, strong sensitizers, substances that are assimilated or
concentrated in and are detrimental to tissue or that generate pressure
through decomposition or chemical reaction.
12.2
Applicability and Exemptions
12.2.1 Except as provided in subsection 12.2.2, any incinerator, except residential
incinerators and those used for the degradation of hazardous materials, must
comply with the provisions and limitations of this regulation.
12.2.2 Any incinerator subject to Sections 39.3 through 39.10 of Rhode Island Air
Pollution Control Regulation No. 39 is not subject to this regulation.
12.3
Emission Standards
12.3.1 Small Incinerators
No person shall construct, install, use or cause to be used any small incinerator that
will emit more than 0.16 gr/dscf (0.36 g/dscm) of particulate matter corrected to 12
percent CO2, maximum two-hour average.
12.3.2 Large, Pathological and Special Incinerators
No person shall construct, install, use or cause to be used any large, pathological or
special incinerator that will emit more than 0.08 gr/dscf (0.18 g/dscm) of particulate
matter corrected to 12 percent CO2, maximum two-hour average.
12.3.3 Particulate Emissions from Sewage Sludge Incinerators
5
No person shall construct, install, use or cause to be used any sewage sludge
incinerator that will emit more than 1.30 pounds of particulate matter per ton of dry
sludge input.
12.4
Permit to Construct
12.4.1 No person shall construct, install, use or cause to be used any incinerator
unless it is a type approved by the Director for being effective for air
pollution control.
12.4.2 No person shall construct, install or operate any incinerator before the
following minimum information has been submitted to the Director:
(a)
Design parameters of the incinerator;
(b)
Design drawings of the incinerator;
(c)
Design specifications of air pollution control equipment;
(d)
Types of waste proposed to be incinerated; and
(e)
Any other information required by the Director.
12.5
Determination of Compliance
Compliance with Section 12.3 shall be determined by one of the following
procedures:
(a)
Emission testing conducted by the owner or operator of the source
according to Method 5 of Appendix A to Part 60 of Title 40 of the
Code of Federal Regulations, or by another method that has the prior
approval of or is required by the Director;
(b)
Technical evaluation based on such factors which may include
type(s) of refuse burned; design of the incinerator, design efficiency
of air pollution control systems, and emission test results on similar
incinerators;
(c)
Any other emission testing method as required and approved by the
Director.
6
12.6
Prohibitions
12.6.1 No person shall construct, install, use or cause to be used any single chamber
flue-fed incinerator.
12.7
Hazardous Waste Incinerators
12.7.1 Rules and regulations governing the incineration of hazardous waste are
contained in the Office of Waste Management’s regulations entitled “Rules
and Regulations for Hazardous Waste Management.”